Honeywell

MK XXII EGPWS Installation Manual

SIGNAL

Uncorrected Barometric Altitude

Outside Air Temp Total Air Temperature

CONNECTION

(+)= J1-62 (-) = J1-43

TABLE E 3.1.2-4: AIR DATA INPUT SELECT #4

SUMMARY DATA

Format: DC with Validity Flag

Input Type: Basic

Fault Designation: BAROMETRIC ALTITUDE FAULT

Validity: Barometric Alt Valid (+28V)

Format: DC

Input Type: Basic

Fault Designation: STATIC AIR TEMPERATURE FAULT

Probe element Excitation:

Temp Input (probe element):

Ground

5 V = J1-25

(+)= J1-63 (-) = J1-44

GND = J1-53

J1

OAT PROBE ELEMENT

Voat

25(5 V Ref)

4.42K Ohms

63

 

+

 

Temp In

-

44

 

 

 

 

 

 

 

 

 

 

 

 

53 Chassis Gnd

Computed Airspeed

PIN FUNCTION

Barometric Altitude Validity Discrete (+28V)

No Connection

CONNECTION

J1-9

N/A

PIN TYPE

Input

Note: Nominal 500 Temperature Probe only.

Resistance @ 0°C: 500Ω ± 0.6

Connection example:

CIC Temperature Sensor, P/N 05257 (2 wire). Connect positive lead to both J1-25 and J1-63. Connect negative lead to both J1-44 and J1- 53 (Chassis Ground).

Other probes may have three contacts.

Substitute Ground Speed for Airspeed (airspeed is not available with this air data input)

 

CHANNEL

 

 

 

 

DESIGNATION

 

Polarity/Configuration

References

 

REFERENCE

 

 

 

 

28V_DISC_08

 

>+17V = Valid

6.6.19

 

 

 

< +4.4V = Invalid

4.2.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

Summary Data

 

 

 

 

 

 

Analog

 

 

Baro Altitude Rate is derived using

 

 

 

 

 

 

 

 

 

 

Uncorrected Barometric Altitude. Baro Rate

 

 

 

 

 

 

 

 

 

is not available with this air data source.

 

 

TABLE E 3.1.2-5: AIR DATA INPUT SELECT #5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fault Designation: AIR DATA BUS

 

 

 

 

 

 

 

 

 

 

 

 

Bus Type: Basic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Label

 

Sig. Bits

Range

 

Signal Type

 

Resolution

Rate (ms)

203

 

17

±131,072 FT

 

Basic

1.0

31.3-62.5

204

 

17

±131,072 FT

 

Basic

1.0

31.3-62.5

206

 

14

±1024 KTS

 

Basic

0.0625

62.5-125

212

 

11

±32678 FPM

 

Basic

16.0

31.3-62.5

213

 

11

±512 Degrees

 

Basic

0.25

250-500

Configuration Data

Derive Baro Altitude Rate

 

 

 

CONNECT TO:

 

 

CHANNEL

 

 

 

ADC #1 (Low Speed)

 

 

429RX_2

 

 

 

 

Format: ARINC 429

 

 

 

 

 

 

A = J2-39

 

Data

 

 

B = J2-38

 

Uncorrected. Baro. Alt

 

 

 

 

Corrected Baro. Alt

 

 

 

 

Computed Airspeed

 

 

 

 

Barometric Rate

 

 

 

 

Static Air Temperature

 

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225

REV: C SHEET 192

Page 192
Image 192
Honeywell MKXXII Table E 3.1.2-4 AIR Data Input Select #4 Summary Data, Table E 3.1.2-5 AIR Data Input Select #5