Honeywell MKXXII installation manual SCI Bus RS-422 12K baud

Models: MKXXII

1 254
Download 254 pages 42.79 Kb
Page 230
Image 230

Honeywell

MK XXII EGPWS Installation Manual

Table E 3.1.6-255 Honeywell SPZ8000 (w/ SCI range)

Display Configuration Group 255 (Honeywell SPZ8000 older style)

Function

Display Type

Sweep Type

Auto Pop Up

Peaks Mode (Elevations via overlay)

Manual select

Manual deselect

Auto Range

Moving Marker

Overlay Page

Display bus type

TERRAIN DISPLAY BUS #1 453TX_1

A= J1-58

B= J1-59

TERRAIN DISPLAY BUS #2 453TX_2

A= J1-56

B= J1-57

Value

Honeywell (5x6) (SPZ8000) older style; does not blank every fourth weather radar display line. This interface supports SG-810 and SG- 811 SPZ8000 systems only.

Honeywell

Category 7, Options Select Group #1

TA&D Alternate Pop Up: False

TA&D Alternate Pop Up: True

Pop Up On Caution or Warning

Never Pop Up

Category 7, Options Select Group #1

Peaks Enable: False

Peaks Enable: True

Peaks Off

Peaks On

Controlled by SPZ8000 display system

Controlled by SPZ8000 display system

Yes (10 NM)

Yes (Honeywell type)

Yes, for Peaks Elevations (located on lower right side)

Honeywell picture bus

CONNECT TO:

Terrain Display data to switching relay/Symbol Generator #1

CONNECT TO:

Terrain Display data to switching relay/Symbol Generator #2 (NOTE: Range setting always follows Display Bus #1).

Display Input Control Group 255

CHANNEL 429_422RX_1

A= J2-36

B= J2-37

CONNECT TO:

SCI Bus 1

(RS-422 - 12K baud)

Data

Range (Mode/Range Word)

Fault Designation: DISPLAY BUS 1

Bus Type: Basic

Label

Sig. Bits

Range

Signal Type

80

4 Discrete

2000NM

Basic

OUTPUT 429 BUS GROUP 0

Resolution

N/A

Rate (ms) 100

Channel

429TX_1 (Low Speed)

429TX_2

Pins

A = J2-43 B = J2-42

A = J2-26 B = J2-9

Comments

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x and 7.1.4.x

No Connection (No Data Output)

Integration Notes:

The EGPWS ARINC 429 Output Bus must be connected to the SPZ8000 display.

This display type may also be used for an integrated P880/660/440 display, but requires Auto Pop Up to be disabled and relay selection to be controlled directly from an alternate action switch (for new installations of P880/660/440 use ID 13).

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225