E 5.3.2 CATEGORY 2, AIR DATA INPUT SELECT

The following table provides identification of the Air Data source type. The entry in the Air Data Type corresponds to a table that provides detailed information on the configuration. For example, the details for Air Data Type #2 are found in Table E 3.1.2. In this category, only the following signals are defined:

Uncorrected Barometric Altitude in analog and/or RS-422 or ARINC 429 format, and associated validity.

Temperature (Outside Air or Static Air) in analog or ARINC 429 format.

Corrected Barometric Altitude in ARINC 429 format.

Barometric Rate in ARINC 429 format.

Computed Airspeed in ARINC 429 format.

TABLE E 3.1.2: AIR DATA INPUT SELECT FOR EGPWS MKXXII

ID

0

1

2

3

4

5

6

10

11

12

Air Data Type

(Table E 3.1.2-x)

0

1

2

3

4

5

6

10

11

12

Description

Analog - altitude and 500OAT (i.e., CIC

04077)

Digital – ARINC 429 (i.e., Bendix KDC 281)

Digital – ARINC 575 (i.e., Collins ADC-80,

81, 82)

Analog - altitude and 500OAT (i.e., Collins

ADS-65)

Analog - altitude and 500OAT (i.e., CIC

02702)

Digital – ARINC 429 with Corrected Altitude

label 204

(i.e., Bendix KDC 481T)

Digital – ARINC 429 without Baro Rate label 212

(i.e., Honeywell AZ-810)

Digital – ARINC 429 and 500OAT (i.e. Shadin 2000)

Analog – altitude and 500OAT (i.e., Honeywell AZ-241 or AZ-800 with additional OAT). (Note 1)

Analog – altitude and internal constant for OAT (i.e., Honeywell AZ-800 or AZ-241). (Note 1)

Effectivity

 

 

 

 

 

App.

Cfg.

 

 

-001

-001

 

 

 

 

 

 

-001

-001

 

 

-001

-001

 

 

 

 

 

 

-001

-001

 

 

 

 

 

 

-001

-001

 

 

 

 

 

 

-001

-001

 

 

 

 

 

 

-001

-001

 

 

 

 

 

 

-003

-003

 

 

 

 

 

 

-004

-004

 

 

 

 

 

 

-006

-006

 

 

 

 

 

Note 1: The AZ-800 provides an OAT signal with reference provided by the ADC. This is not compatible with the EGPWS interface. The AZ-241 provides no OAT interface. The customer may either add an additional OAT probe (ID 11) or use the internal constant (ID 12). ID 11 is to be recommended in operations in temperature extremes.

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225