Honeywell MKXXII installation manual Table Table E 3.1.6-1 No Display TAD and TCF Enabled, Channel

Models: MKXXII

1 254
Download 254 pages 42.79 Kb
Page 205
Image 205

Honeywell

MK XXII EGPWS Installation Manual

Table Table E 3.1.6-1 No Display – TAD and TCF Enabled

OUTPUT 429 BUS GROUP 0

Channel

429TX_1 (Low Speed)

429TX_2

Pins

A = J2-43 B = J2-42

A = J2-26 B = J2-9

Comments

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x and 7.1.4.x

No Connection (No Data Output)

Table Table E 3.1.6-2 TA&D / TCF Disabled

OUTPUT 429 BUS GROUP 0

Channel

429TX_1 (Low Speed)

429TX_2

Pins

A = J2-43 B = J2-42

A = J2-26 B = J2-9

Comments

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x and 7.1.4.x

No Connection (No Data Output)

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225

REV: C SHEET 205