Honeywell

MK XXII EGPWS Installation Manual

E.Slide the EGPWS unit in the mounting tray, and secure it using the Hold Down latch.

F.(After Continuity and Power check) Attach the cable harness to the front panel connectors and lock connectors using the slide lock of the P1 & P2 connectors. The EGPWS should be wired according to the interconnect diagrams in Section III, of this manual.

2.3.4 Configuration Module Location

The aircraft configuration is programmed into the EGPWS Configuration Module installed in the aircraft wiring. The Configuration Module is identified as Honeywell part number 700-1710-001. The Configuration Module is installed as one side of the P2 (50 pin) mating connector backshell and contains electrically reprogrammable memory for configuration storage. The Configuration Module when installed is wired directly to the appropriate pins in the P2 connector.

2.3.5 Configuration Module Installation

The purpose of this procedure is to give an assembly sequence for assembly of the Configuration Module with the P2 connector and backshell.

A.The P2 connector, Honeywell part number 440-1233-001, vendor part number RD50F1OJVLC-15, when ordered comes with 50 contacts and a plastic backshell (hood).

B.The Configuration Module will replace the Backshell Plate. The Backshell Plate can be discarded.

C.Wire the Configuration Module to the P2 connector using contacts provided with the connector. Wire per the following wire list:

Wire Color

P2 pin #

Wire Color

P2 pin #

Violet

P2-17

Black

P2-50

Blue

P2-16

White

P2-49

Orange

P2-33

Red

P2-32

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225

REV: C SHEET 35

Page 35
Image 35
Honeywell MKXXII installation manual Configuration Module Location, Configuration Module Installation