3.3.9.2Example

3.3.9.3Analog Glideslope Interface (cat. 9 ID 0,1,5)

EGPWS MK XXII

J2

 

GS Deviation

+

65

 

-

46

 

 

 

GS Valid +28

11

 

Low Level

+

30

 

GS Valid

-

10

 

ILS Tuned

+28

39

 

 

GND

20

 

 

 

 

 

 

 

ILS Receiver

+Up

GS Deviation

+Dn

Super Flag +28V

+ GS Flag

-(Low Level)

Delayed ILS Mode

ILS Energize

Vendor Model

Honeywell

KNR 630

Honeywell

KNR 634

Honeywell

KGM-691

Honeywell

KNR 600A

Collins

51RV-1

Collins

VIR-30, -31, -32

Honeywell

VNS 41A

Honeywell

RNA-34A

Honeywell

KN 53

Honeywell

RNZ 850

Valid

SuperFlag Low Level

+28V Flag

J1003-27 J1003-21

J1003-22

P6342-50 P6342-34

P6342-18

P692-S

P692-T

P601-e

P601-q

TP-22

TP-21

P1-17 J1-9

J1-13

P1001-60

TP-27

TP-21

 

 

P2-13

P2-R

P1-A74

ILS Tuned

+28V GND

J1002-18

P6341-17

P692-a

P601-k

BP-18

P2-40

J1001-56

BP-18

P2-12

P1-B64

Deviation

GS

+up/+dn

J1003-8

J1003-9

P6342-36

P6342-35

P692-B

P692-C

P601-r

P601-s

TP-8

TP-9

P1-5

P1-1

J1001-90

J1001-23

TP-8

TP-9

P2-P

P2-14

P1-B79

P1-B75

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225