Honeywell

MK XXII EGPWS Installation Manual

Table Table E 3.1.6-3 Collins ProLine II (4x4)

DISPLAY CONFIGURATION GROUP 6 (COLLINS PRO-LINE II, 4X4)

Function

Display Type

Sweep Type

Auto Pop Up

Value

Collins Pro-Line II (4x4) Display

Standard with +/-60 degree limit

Category 7, Options Select Group #1

TA&D Alternate Pop Up: False

TA&D Alternate Pop Up: True

Pop Up On Caution or Warning

Never Pop Up

Peaks Mode (Elevations via overlay)

Category 7, Options Select Group #1

Peaks Enabled: False

Peaks Enabled: True

Peaks Off

Peaks On

Auto Range

Moving Marker

Overlay Page

Display bus type

DISPLAY BUS #1 453TX_1

A= J1-58

B= J1-59

DISPLAY BUS #2 453TX_2

A= J1-56

B= J1-57

No

No

Yes; “TERR” located on the left side of display.

Peaks Elevations located on the upper left side of Terrain image.

Standard ARINC 453

CONNECT TO:

Terrain Display data to switching relay/Symbol Generator

CONNECT TO:

Terrain Display data to switching relay/Symbol Generator

DISPLAY INPUT CONTROL GROUP 1

CHANNEL 429_422RX_1

A= J2-37

B= J2-36

CHANNEL 429RX_3

CONNECT TO: WX-IND 429 out (range) Bus 1 (Low Speed)

Data

Range (Display Word 2)

CONNECT TO: WX-IND 429 out (range) Bus 2 (Low Speed)

Fault Designation: DISPLAY BUS 1

Bus Type: Basic

 

 

 

 

 

 

 

Label

Sig. Bits

Range

Signal Type

Resolution

Rate (ms)

 

271

Discrete

5-320NM

Basic

N/A

100

 

Fault Designation: DISPLAY BUS 2

Bus Type: Basic

A= J2-41

B= J2-40

CONN PIN #

J1-32

J1-31

Data

Range (Display Word 2)

REFERENCE NAME

GND_DISC_12

GND_DISC_13

Label

Sig. Bits

Range

271

Discrete

5-320NM

PIN FUNCTION

Display Select Discrete #1

Display Select Discrete #2

OUTPUT 429 BUS GROUP 0

Signal Type

Resolution

Rate (ms)

Basic

N/A

100

Polarity/Configuration

Type 1 (Momentary)

Gnd = Display Select Toggle <not> Gnd = Normal

Type 1 (Momentary)

Gnd = Display Select Toggle <not> Gnd = Normal

Channel

429TX_1 (Low Speed)

429TX_2

Pins

A = J2-43 B = J2-42

A = J2-26 B = J2-9

Comments

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x and 7.1.4.x

No Connection (No Data Output)

Integration note:

When interfacing to a single display controller configuration the bus must be connected to both EGPWS input channels. This prevents the EGPWS from reporting an external bus fault on the second channel.

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225

REV: C SHEET 206

Page 206
Image 206
Honeywell MKXXII Table Table E 3.1.6-3 Collins ProLine II, Fault Designation Display BUS Bus Type Basic, Integration note