Table E 3.1.6-9

Non-Integrated EFIS 40/50 (Honeywell/Bendix)

 

DISPLAY CONFIGURATION GROUP 7 (NON-INTEGRATED EFIS 40/50)

 

 

 

 

Function

Display Type

Sweep Type

Auto Pop Up

Value

Bendix Non-Integrated EFIS 40/50

Sweep range +/- 60 degrees

Category 7, Options Select Group #1

TA&D Alternate Pop Up: False

TA&D Alternate Pop Up: True

Pop Up when display is in the

Never Pop Up

proper mode.

 

Peaks Mode (Peaks Elevations are in Terrain Image, replacing “TERR”)

Manual select

Manual deselect

Auto Range

Moving Marker

Overlay Page

Display bus type

DISPLAY BUS #1 453TX_1

A= J1-58

B= J1-59

Category 7, Options Select Group #1

Peaks Enabled: False

Peaks Enabled: True

Peaks Off

Peaks On

Anytime WXR is on and display is in proper Mode

Anytime

No

No

Yes; “TERR” at upper right corner of display.

Standard ARINC 453

CONNECT TO:

Terrain Display data to switching relay/Symbol Generator

DISPLAY BUS #2 453TX_2

A= J1-56

B= J1-57

CONNECT TO:

Terrain Display data to switching relay/Symbol Generator

DISPLAY INPUT CONTROL GROUP 2

CHANNEL 429_422RX_1

A= J2-37

B= J2-36

CHANNEL 429RX_3

CONNECT TO: WX-IND 429 out (range) Bus 1 (Low Speed)

Data

Mode (Display Word 1)

Range (Display Word 2)

Discrete Word (VP)

CONNECT TO: WX-IND 429 out (range) Bus 2 (Low Speed)

Fault Designation: DISPLAY BUS 1

Bus Type: Basic

 

 

 

 

 

 

 

Label

Sig. Bits

Range

Signal Type

Resolution

Rate

 

270

Discrete

Mode, Tilt, Gain

Basic

N/A

100 ms

 

271

Discrete

5-320NM

Basic

N/A

100 ms

 

273

Discrete

VP Mode, Bit 11

Basic

N/A

100 ms

 

Fault Designation: DISPLAY BUS 2

Bus Type: Basic

A= J2-41

B= J2-40

CONN PIN #

J1-32

J1-31

Data

Mode (Display Word 1)

Range (Display Word 2)

Discrete Word (VP)

REFERENCE NAME

GND_DISC_12

GND_DISC_13

Label

Sig. Bits

Range

270

Discrete

Mode, Tilt, Gain

271

Discrete

5-320NM

273

Discrete

VP Mode, Bit 11

PIN FUNCTION

Display Select Discrete #1

Display Select Discrete #2

OUTPUT 429 BUS GROUP 0

Signal Type

Resolution

Rate

Basic

N/A

100 ms

Basic

N/A

100 ms

Basic

N/A

100 ms

Polarity/Configuration

Type 1 (Momentary)

Gnd = Display Select Toggle <not> Gnd = Normal

Type 1 (Momentary)

Gnd = Display Select Toggle <not> Gnd = Normal

Channel

429TX_1 (Low Speed)

429TX_2

Pins

A = J2-43 B = J2-42

A = J2-26 B = J2-9

Comments

Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x and 7.1.4.x

No Connection (No Data Output)

Integration note:

When interfacing to a single display controller configuration the bus must be connected to both EGPWS input channels. This prevents the EGPWS from reporting an external bus fault on the second channel.

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225

REV: C SHEET 210

Page 210
Image 210
Honeywell MKXXII installation manual Table E Non-Integrated Efis 40/50 Honeywell/Bendix