Honeywell

MK XXII EGPWS Installation Manual

SIGNAL

Uncorrected Barometric Altitude

Outside Air Temp Total Air Temperature

CONNECTION

(+)= J1-62 (-) = J1-43

TABLE E 3.1.2-0: AIR DATA INPUT SELECT #0

SUMMARY DATA

Format: DC with Validity Flag

Input Type: Basic

Fault Designation: BAROMETRIC ALTITUDE FAULT

Validity: Barometric Alt Valid (+28V)

Format: DC

Input Type: Basic

Fault Designation: STATIC AIR TEMPERATURE FAULT

Probe element Excitation:

Temp Input (probe element):

Ground

5 V = J1-25

(+)= J1-63 (-) = J1-44

GND = J1-53

J1

OAT PROBE ELEMENT

Voat

25(5 V Ref)

4.42K Ohms

63

 

+

 

Temp In

-

44

 

 

 

 

 

 

 

 

 

 

 

 

53 Chassis Gnd

Computed Airspeed

PIN FUNCTION

Barometric Altitude Validity Discrete (+28V)

No Connection

CONNECTION

J1-9

N/A

PIN TYPE

Input

Note: Nominal 500 Temperature Probe only.

Resistance @ 0°C: 500Ω ± 0.6

Connection example:

CIC Temperature Sensor, P/N 05257 (2 wire). Connect positive lead to both J1-25 and J1-63. Connect negative lead to both J1-44 and J1- 53 (Chassis Ground).

Other probes may have three contacts.

Substitute Ground Speed for Airspeed (airspeed is not available with this air data input)

 

CHANNEL

 

 

 

 

DESIGNATION

 

Polarity/Configuration

References

 

REFERENCE

 

 

 

 

28V_DISC_08

 

>+17V = Valid

6.6.19

 

 

 

< +4.4V = Invalid

4.2.7

 

 

 

 

 

 

 

 

 

 

Configuration Data

Derive Baro Altitude Rate

 

CONNECT TO:

CHANNEL

ADC #1 (Low Speed)

429RX_2

Format: ARINC 429

 

A = J2-39

Data

B = J2-38

Uncorrected. Baro. Alt

 

Computed Airspeed

 

Barometric Rate

 

Static Air Temperature

 

 

 

CONNECT TO:

CHANNEL

ADC #1 (Low Speed)

429RX_2

Format: ARINC 575

 

A = J2-39

Data

B = J2-38

Uncorrected. Baro. Alt

 

Computed Airspeed

 

Barometric Rate

 

Static Air Temperature

 

 

 

 

Type

 

 

 

Summary Data

 

 

 

 

Analog

 

 

Baro Altitude Rate is derived using

 

 

 

 

 

 

 

 

 

Uncorrected Barometric Altitude. Baro Rate

 

 

 

 

 

 

 

 

is not available with this air data source.

TABLE E 3.1.2-1: AIR DATA INPUT SELECT #1

 

 

 

Fault Designation: AIR DATA BUS

 

 

 

 

 

 

Bus Type: Basic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Label

 

Sig. Bits

 

Range

 

Signal Type

Resolution

Rate (ms)

 

203

 

 

17

 

±131,072 FT

 

Basic

1.0

31.3-62.5

 

206

 

 

14

 

±1024 KTS

 

Basic

0.0625

62.5-125

 

212

 

 

11

 

±32768 FPM

 

Basic

16.0

31.3-62.5

 

213

 

 

11

 

512 Degrees

 

Basic

0.25

250-500

TABLE E 3.1.2-2: AIR DATA INPUT SELECT #2

 

 

 

 

 

 

 

 

 

Fault Designation: AIR DATA BUS

 

 

 

 

 

 

Bus Type: Basic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Label

 

Sig. Bits

 

Range

 

Signal Type

Resolution

Rate (ms)

 

203

 

 

17

 

±131,072 FT

 

Basic

1.0

31.3-62.5

 

206

 

 

13

 

±1024 KTS

 

Basic

0.125

62.5-125

 

212

 

 

11

 

±20480 FPM

 

Basic

10.0

31.3-62.5

 

213

 

 

10

 

±512 Degrees

 

Basic

0.5

250-500

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225

REV: C SHEET 190

Page 190
Image 190