Honeywell

MK XXII EGPWS Installation Manual

SIGNAL

Engine Torque #1

Engine Torque #2

CONNECTION

(+)= J1-26 (-) = J1-27

(+)= J1-66 (-) = J1-47

TABLE E 3.1.1-12

TORQUE DATA SELECT 14 (COAST GUARD HH-65)

SUMMARY DATA

Format: DC

Input Type: Basic

Fault Designation: ENGINE TORQUE 1

Validity: none

Format: DC

Input Type: Basic

Fault Designation: ENGINE TORQUE 2

Validity: none

SIGNAL

Engine Torque #1

Engine Torque #2

SIGNAL

Engine Torque #1

Engine Torque #2

TABLE E3.1.1-13

: TORQUE DATA SELECT 15 (GENERIC FIXED TORQUE 20%)

CONNECTION

 

SUMMARY DATA

No Connection

 

Format: Fixed Internal

 

 

Input Type: Basic

 

 

Fault Designation:

No Connection

 

Format: Fixed Internal

 

 

Input Type: Basic

 

 

Fault Designation:

 

 

 

TABLE E3.1.1-14

 

TORQUE DATA SELECT 16 (COMMON DC TORQUE)

CONNECTION

 

 

SUMMARY DATA

(+) = J1-26

 

 

Format: DC

(-) = J1-27

 

 

Input Type: Basic

 

 

 

Fault Designation: ENGINE TORQUE 1

(+) = J1-66

 

 

Format: DC

(-) = J1-47

 

 

Input Type: Basic

 

 

 

Fault Designation: ENGINE TORQUE 2

CHANNEL RX429-8

A= J2-24

B= J2-07

TABLE E3.1.1-15

TORQUE DATA SELECT 17 (GENERIC SHADIN DC TO 429 CONVERTER)

CONNECT TO:

 

Fault Designation: ENGINE 1 BUS

 

 

Eng #1 (high speed)

 

 

 

 

Bus Type: Basic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data

 

Label

Sig. Bits

 

Range

Signal Type

Resolution

Rate (ms)

Torque 1

 

053

15

 

0 to 180%

Basic

0. 0078125

50

Torque 2

 

054

15

 

0 to 180%

Basic

0. 0078125

50

Note 1: The actual number of significant bits is 16 but 15 bits will support the data range. This is adjusted to make the input processing work with the actual MSB = to bit 29.

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225

REV: C SHEET 188

Page 188
Image 188
Honeywell MKXXII installation manual Fault Designation Engine 1 BUS, Torque Data Select 14 Coast Guard HH-65 Summary Data