The Ground discretes are internally biased via a pull up resistor, and are externally pulled down to ground when active. The characteristics of each Ground discrete input are as follows:

Ground Discrete Characteristics

 

Quantity

15

Active Voltage Range (Logic True)

< +3 VDC

Inactive Voltage Range (Logic False)

> 100 K(to ground) or > +3.5 VDC

Diode Isolation

Each input is diode isolated to prevent current sinking

Input Impedance

> 10 K

Maximum Fault Current

< 100 A (at +28 VDC input)

Pin Assignment (Signal Mnemonic):

See specific discrete in Category 13 (GND_DISC_xx)

E 4.2.11 CONFIGURATION MODULE INTERFACE

System configuration is defined via a Configuration Module, which resides in the MKIV/VI/VIII/XXII EGPWS aircraft wiring harness backshell. The EGPWS Configuration Module contains the aircraft interface and functionality definitions specific to the installed aircraft. Refer to Section 5 for interface and functional definitions by category.

Electrical Characteristics Data definition

Pin Assignment (Signal Mnemonic): Clock

Master Data Out

Master Data In Configuration Module Select Configuration Module +5VDC Configuration Module +5VDC Return

Refer to the EGPWS Configuration Module specification Refer to the EGPWS Configuration Module specification

J2-32 (RED)

(SPICLK)

J2-50 (BLK)

(SPIMOSI)

J2-33

(ORN)

(SPIMISO)

J2-49

(WHT)

(SPISEL_CM#)

J2-17

(VIO)

(SC_PWR)

J2-16 (BLU)

(GND)

Output to Config Module

Clock Out

Master Data Out

Config Module Select

Logic Low (nominal)

EMK4/6/8/22

0 V

0 V

0 V

Logic High (nominal)

EMK4/6/8/22

5 V

5 V

5 V

INTERFACE OF EGPWS OUTPUTS TO CONFIGURATION MODULE

E 4.2.12 GPS ANTENNA INPUT

A GPS input connector is available on the front of the MK VI EGPWS (965-1186-0XX only), MK VIII EGPWS (965-1216- 0XX only), MK XXII EGPWS (965-1590-0XX only), and MK IV EGPWS (965-1686-0XX only).

Quantity

1

 

Cable Length/Allowed Signal Loss

Not more than 8 dB, at 1575.42 MHz, for cable and

 

connector loss from antenna to unit.

Connector Type

TNC

 

Low Level DC on RF Output

+5 VDC ±5%, 50 mAmps maximum, Shield Ground.

Pin Assignment (Signal Mnemonic):

GPS ANT

(COAX)

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225

REV: C SHEET 175