When used as a validity input:

 

Active Voltage Range (Logic True)

+160 to +840 mVDC

Inactive Voltage Range (Logic False)

0 to 50 mVDC

Broken Wire Detect

Input will be biased less than –1 VDC

When used as a localizer input:

±12 Dots

Signal Range

Input Voltage Range

±0.9VDC

Broken Wire Detect

Input will be biased less than -15 dots

E 4.2.4

BAROMETRIC ALTITUDE

 

 

Quantity

 

1

 

Input Impedance, each leg

> 83 K

 

Reverse Fault Current

< 200 amps

 

Input Voltage Range

-0.18VDC to +15VDC

 

Input Filter

0.1 Second Low Pass, ± 10%

Input Type

Differential

 

Broken Wire Detect

Input will be biased less than -3000 feet

Pin Assignment (Signal Mnemonic):

 

 

 

Signal (+)

J1-62

(ALT_H)

 

Return (-)

J1-43

(ALT_L)

E 4.2.5

OUTSIDE AIR TEMPERATURE

 

 

Quantity

 

1

 

Input Impedance, each leg

> 100 K

 

Reverse Fault Current

< 200 amps

 

Input Voltage Range

+0.3 VDC to +0.6VDC

Input Filter

0.1 Second Low Pass, ± 10%

Input Type

Differential

 

Broken Wire Detect

Input will be biased less than -80°C

Pin Assignment (Signal Mnemonic):

 

 

 

Signal (+)

J1-63

(OAT_H)

 

Return (-)

J1-44

(OAT_L)

NOTE: For temperature probe voltage reference see section 0.

E 4.2.6 CONFIGURATION DEFINED DC INPUTS

Quantity

2

 

Input Impedance, each leg

> 83 K

 

Reverse Fault Current

< 200 amps

 

Input Voltage Range

±5 VDC

 

Input Filter

0.1 Second Low Pass, ± 10%

Input Type

Differential

 

Broken Wire Detect

Input will be biased less than –6 VDC

Pin Assignment (Signal Mnemonic):

 

 

#1 Signal (+)

J1-26

(TORQUE_1H)

#1 Return (-)

J1-27

(TORQUE _1L)

#2 Signal (+)

J1-66

(TORQUE _2H)

#2 Return (-)

J1-47

(TORQUE _2L)

CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225

REV: C SHEET 169