Honeywell

MK XXII EGPWS Installation Manual

SECTION IV – CONFIGURATION MODULE PROGRAMMING AND

REGIONAL TERRAIN DATABASE LOADING

4.1 Introduction

The following procedures outline the steps necessary to accomplish a complete configuration of the MK XXII EGPWS. This section must be accomplished in the order presented to minimize errors in configuring and operating the system(s). If problems are encountered in performing these procedures, the installer may refer to aircraft wiring diagrams for harness troubleshooting or the aircraft maintenance manual to isolate faulty equipment. All discrepancies should be resolved before proceeding. This section will also load the Regional Terrain Database in MK XXII EGPWS that will be operating outside of the North American region.

4.2 Harness Checkout and Power Check

Prior to installing any equipment, it is important to verify that all interfaces have been made and that power and ground at each unit connector is correct, using the wiring diagrams for the installation. Any discrepancies in the wiring must be resolved before proceeding.

The wire harness should also be checked for proper clearance near any control cables and other potential areas that may cause binding and/or chafing.

4.3 Unit Installation

After the harness check has been completed and any discrepancies have been resolved, the units should be installed into their respective racks, and all connections to the wiring harness should be made (connectors attached). Verify that all of the units are secure in their respective racks, panels, etc., and all harness connections are secure. Refer to aircraft installation drawings for the unit locations and mounting information.

4.4 EGPWC Initialization a nd Configuration

The first time a MK XXII EGPWS is turned on in a new installation, the Configuration Module in the EGPWS harness must be programmed to the specific interface configuration for the aircraft. This programming is done via RS-232 cable connection between the EGPWC and a PC running the Honeywell WinViews software. This interface capability is provided to facilitate diagnostic and configuration functions with the EGPWC during post installation checkout. Refer to Appendix C for instructions related to using the WinViews software.

4.4.1 RS-232 Communicatio n with the MK XXII EGPWS

The MK XXII EGPWS computer contains software that allows monitoring of its internal

 

 

 

 

 

 

 

 

 

 

 

CAGE CODE:

 

SCALE: NONE SIZE: A DWG NO: 060-4314-225

 

REV: C

109

97896

 

 

 

SHEET

 

 

 

 

 

 

 

 

 

 

Page 109
Image 109
Honeywell MKXXII Harness Checkout and Power Check, Unit Installation, Egpwc Initialization a nd Configuration