Safety precautions

Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.

Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components.

Verify that installation and testing operations are performed by qualified personnel.

Verify that the air conditioner is not installed in an easily accessible area.

General information

Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation.

For maximum safety, installers should always carefully read the following warnings.

Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred.

This manual explains how to install an indoor unit with a split system with two SAMSUNG units.

The use of other types of units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.

The air conditioner is compliant with the requirements of the Low Voltage Directive (72/23/EEC), the EMC Directive (89/336/EEC) and the Directive on pressurized equipment (97/23/EEC).

The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the“Operating limits”table, included in the manual, shall immediately invalidate the warranty.

The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.

Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.

In order to prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.

Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations should be performed by qualified personnel only.

The unit contains moving parts, which should always be kept out of the reach of children.

Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may cause electric shocks or fires.

Do not place containers with liquids or other objects on the unit.

All the materials used for the manufacture and packaging of the air conditioner are recyclable.

The packing material and exhaust batteries of the remote controller(optional) must be disposed of in accordance with current laws.

The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely.

ENGLISH

25

UMG_AQ&AS18V@_IBIM_34038A_E--P14P18���������.indd 25

2013-3-18 11:00:13

Image 25
Contents English Contents Important safety symbols and precautions SafetAA y precautionsFollow directions Wall socketFor Using For Cleaning Operation ranges ChecAA king before useSet temperature Mode indicator Auto clean indicatorMode indicator Room temperature ChecAA king the name of the partsRemote controller buttons ChecAA king the remote controllerBattery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasicAA function Press the button to set the desired fan speed Press the button to adjust the temperaturePress the Air swing button on the remote controller Using the Turbo functionAdjusA ting the air flow direction Vertical air flowPress the button on the remote controller AA modePress the Set/Cancel button to active it on Set Off timerPress the On Timer/Off Timer button SettinAA g the On/Off timerPress the On Timer/Off Timer button to set the time If the air conditioner is on If the air conditioner is off From the moment you have set the timerTurn off automatically Using the dlight Cool function Using the Smart Saver functionUsing the Virus Doctor function Using the Quiet function UsingAA the Auto Clean functionWhen the air conditioner is turned on RunsCleaning the outdoor unit heat exchanger Cleaning the indoor unitOpening the panel Heat exchangerRemoving the Air filter Cleaning the air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaClose the front panel Deodorizing and Bio filterPeriodical checks MainAA taining the air conditionerTroubAA leshooting Flow movement changes. It is normal TroubleshootingConnection General information Safety precautionsInstalling the unit Choosing the installation locationPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyOutdoor Unit Where sulfide gas existsModel When installing more than 1 outdoor unit ChoosingAA the installation locationWhen the air outlet is towards the wall  Figure DescriptionAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsCable specification Connecting the assembly cableConnecting the cable Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryCut off the remaining foam insulation Smooth the cut edgesCutting or extending the pipe PurgiAA ng the indoor unitUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flareOuter Diameter Drain hose installationChanging direction of the drain hose AQseries Purging the connected pipesConnect a drain hose to the drain plug Ensure that condensation draining is adequateAdding Refrigerant Gas service port as seen in the pictureIf you use a pipe shorter than 4 or 5m Fixing the indoor unit in place PerfoAA rming the gas leak testsFixinAA g the outdoor unit in place Outdoor unit installed on the wall by rackPress the Power button to stop the operation Press the Mode button to select Cool modeCheck the followings Press the Air swing button and check the followingApply heat to the contraction tube to contract it AAHow to connect your extended power cablesAfter tube contraction work is completed, wrap it with Insulation tape to finishAQ18VBFUMG AQ24VBFUMG TechnAA ical SpecificationsQuestions or COMMENTS? Air Conditioner