Samsung AS24VBFNUMG SafetAA y precautions, Important safety symbols and precautions, Wall socket

Page 3

USING PARTS

SafetAA y precautions

Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance.

Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have any questions, call your nearest contact center or find help and information online at www.samsung.com.

Important safety symbols and precautions:

WARNING Hazards or unsafe practices that may result in severe personal injury or death.

CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage.

Follow directions.

 

Unplug the power plug from the

 

wall socket.

 

 

Do NOT attempt.

 

Do NOT disassemble.

 

 

 

Make sure the machine is grounded to prevent electric shock.

FOR INSTALLATION

WARNING

Plug the power cord into a wall socket with the power specifications of the product or higher and use the socket for this appliance only. In addition, do not use an extension cord.

Sharing a wall socket with other appliances using a power strip or extending the power cord may result in electric shock or fire.

Do not use an electric transformer. It may result in electric shock or fire.

If the voltage/frequency/rated current condition is different, it may cause fire.

The installation of this appliance must be performed by a qualified technician or service company.

Failing to do so may result in electric shock, fire, explosion, problems with the product, or injury.

Install a switch and circuit breaker dedicated to the air conditioner.

Failing to do so may result in electric shock or fire.

Fix the outdoor unit firmly so that the electric part of the outdoor unit is not exposed.

Failing to do so may result in electric shock or fire.

Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak.

This may result in electric shock or fire.

Never install the outdoor unit in a location such as on a high external wall where it could fall.

If the outdoor unit falls, it may result in injury, death or property damage.

This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe, or telephone line.

Failure to do so may result in electric shock, fire, an explosion, or other problems with the product.

Never plug the power cord into a socket that is not grounded correctly and make sure that it is in accordance with local and national codes.

FOR INSTALLATION

CAUTION

This appliance should be positioned in such a way that it is accessible to the power plug.

Failing to do so may result in electric shock or fire due to electric leakage.

Install your appliance on a level and hard floor that can support its weight.

Failing to do so may result in abnormal vibrations, noise, or problems with the product.

Install the draining hose properly so that water is drained correctly.

Failing to do so may result in water overflowing and property damage.

When installing the outdoor unit, make sure to connect the draining hose so that draining is performed correctly.

The water generated during the heating operation by the outdoor unit may overflow and result in property damage. In particular, in winter, if a block of ice falls, it may result in injury, death or property damage.

ENGLISH

3

UMG_AQ&AS18V@_IBIM_34038A_E--P14P18���������.indd 3

2013-3-18 11:00:06

Image 3
Contents English Contents Wall socket SafetAA y precautionsImportant safety symbols and precautions Follow directionsFor Using For Cleaning Operation ranges ChecAA king before useChecAA king the name of the parts Mode indicator Auto clean indicatorSet temperature Mode indicator Room temperatureRemote controller buttons ChecAA king the remote controllerInserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasicAA function Press the button to set the desired fan speed Press the button to adjust the temperatureVertical air flow Using the Turbo functionPress the Air swing button on the remote controller AdjusA ting the air flow directionSet Off timer AA modePress the button on the remote controller Press the Set/Cancel button to active it onSettinAA g the On/Off timer Press the On Timer/Off Timer buttonPress the On Timer/Off Timer button to set the time From the moment you have set the timer If the air conditioner is on If the air conditioner is offTurn off automatically Using the dlight Cool function Using the Smart Saver functionUsing the Virus Doctor function Runs UsingAA the Auto Clean functionUsing the Quiet function When the air conditioner is turned onHeat exchanger Cleaning the indoor unitCleaning the outdoor unit heat exchanger Opening the panelDry the Air filter in a ventilated area Cleaning the air filterRemoving the Air filter Open the panel and put the Air filter outClose the front panel Deodorizing and Bio filterPeriodical checks MainAA taining the air conditionerTroubAA leshooting Troubleshooting Flow movement changes. It is normalConnection General information Safety precautions a place where the air filter can be replaced easily Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerWhere sulfide gas exists Outdoor UnitModel  Figure Description ChoosingAA the installation locationWhen installing more than 1 outdoor unit When the air outlet is towards the wallAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Tools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsConnecting the assembly cable Cable specificationConnecting the cable Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryCut off the remaining foam insulation Smooth the cut edgesPut a flare nut slightly into the pipe and modify the flare PurgiAA ng the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeOuter Diameter Drain hose installationChanging direction of the drain hose Ensure that condensation draining is adequate Purging the connected pipesAQseries Connect a drain hose to the drain plugGas service port as seen in the picture Adding RefrigerantIf you use a pipe shorter than 4 or 5m Fixing the indoor unit in place PerfoAA rming the gas leak testsFixinAA g the outdoor unit in place Outdoor unit installed on the wall by rackPress the Air swing button and check the following Press the Mode button to select Cool modePress the Power button to stop the operation Check the followingsInsulation tape to finish AAHow to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withAQ18VBFUMG AQ24VBFUMG TechnAA ical SpecificationsQuestions or COMMENTS? Air Conditioner