Samsung AS18VBFNUMG, AS24VBFNUMG manual Changing direction of the drain hose

Page 36

Installing and connecting the drain hose of the indoor unit

• If you do not use the other drain hose hole, block it with a rubber stopper.

4. When extending the Drain Hose, hold the end of Drain Hose and Extended Hose,

 

rotate and insert the drain hose into Extended hose for 15~20 mm. Make sure

Drain hose hole

the two hoses are firmly connected, there is no water leakage.

 

5.Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose. Then, Use vinyl tape to wrap the each side of connection by 20mm .

 

 

15~20 mm

20mm

20mm

 

 

or more

or more

 

Drain hose Extension

Drain hose

Extension

 

 

 

drain hose

 

 

 

 

 

drain hose

Vinyl Tape

Foam Insulation

 

 

 

 

6.

Pass the drain hose under the refrigerant pipe, keeping the drain

Shield

 

 

hose tight.

 

 

 

 

 

 

 

 

7.

Pass the drain hose through the hole in the wall. Check if it slants

 

 

 

downwards as seen in the picture.

 

 

 

 

8.

Using natural drainage method, check the drainage is normal.

Drain hose

Extension drain hose

• The hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to page

40 for further details.

• Make sure the installed direction of the drain hose is correct. Inadequate installation may cause condensate water leakage.

• If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors.

DO NOT WALL UP THE DRAIN HOSE CONNECTION !

Drain hose connection must be easy accessible and serviceable.

Changing direction of the drain hose

Change the direction only when it is necessary.

1.

Detach the rubber cap with the plier.

Screw hole

2.

Detach the drain hose by pulling it and turning to the left.

Screw

 

3.

Insert the drain hose by fixing it with the screw into the groove of the drain

Drain hose

 

hose and the outlet of the drain pan.

 

 

4.

Attach the rubber cap with a screwdriver by turning it to the right until it

 

 

fixes to the end of the groove.

Drain pan outlet

 

 

5. Check for leakage on both side of the drain outlet.

 

Pour the water in direction of arrow.

Direction of the drained water

Rubber cap

 

 

Make sure the indoor unit is in upright position when you pour water to check for leakage.

Make sure that the water does not overflow onto the electrical part.

36

UMG_AQ&AS18V@_IBIM_34038A_E--P14P18���������.indd 36

2013-3-18 11:00:19

Image 36
Contents English Contents SafetAA y precautions Important safety symbols and precautionsFollow directions Wall socketFor Using For Cleaning ChecAA king before use Operation rangesMode indicator Auto clean indicator Set temperatureMode indicator Room temperature ChecAA king the name of the partsChecAA king the remote controller Remote controller buttonsRemote controller display Battery changing timeStoring the remote controller Inserting the batteriesBasicAA function Press the button to adjust the temperature Press the button to set the desired fan speedUsing the Turbo function Press the Air swing button on the remote controllerAdjusA ting the air flow direction Vertical air flowAA mode Press the button on the remote controllerPress the Set/Cancel button to active it on Set Off timerSettinAA g the On/Off timer Press the On Timer/Off Timer buttonPress the On Timer/Off Timer button to set the time From the moment you have set the timer If the air conditioner is on If the air conditioner is offTurn off automatically Using the Smart Saver function Using the dlight Cool functionUsing the Virus Doctor function UsingAA the Auto Clean function Using the Quiet functionWhen the air conditioner is turned on RunsCleaning the indoor unit Cleaning the outdoor unit heat exchangerOpening the panel Heat exchangerCleaning the air filter Removing the Air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaDeodorizing and Bio filter Close the front panelMainAA taining the air conditioner Periodical checksTroubAA leshooting Troubleshooting Flow movement changes. It is normalConnection Safety precautions General informationChoosing the installation location Installing the unitPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyWhere sulfide gas exists Outdoor UnitModel ChoosingAA the installation location When installing more than 1 outdoor unitWhen the air outlet is towards the wall  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsConnecting the assembly cable Cable specificationConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberSmooth the cut edges Cut off the remaining foam insulationPurgiAA ng the indoor unit Cutting or extending the pipeUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flareDrain hose installation Outer DiameterChanging direction of the drain hose Purging the connected pipes AQseriesConnect a drain hose to the drain plug Ensure that condensation draining is adequateGas service port as seen in the picture Adding RefrigerantIf you use a pipe shorter than 4 or 5m PerfoAA rming the gas leak tests Fixing the indoor unit in placeOutdoor unit installed on the wall by rack FixinAA g the outdoor unit in placePress the Mode button to select Cool mode Press the Power button to stop the operationCheck the followings Press the Air swing button and check the followingAAHow to connect your extended power cables Apply heat to the contraction tube to contract itAfter tube contraction work is completed, wrap it with Insulation tape to finishTechnAA ical Specifications AQ18VBFUMG AQ24VBFUMGQuestions or COMMENTS? Air Conditioner