AAHow to connect your extended power cables

Items to prepare

(compressor and insulation tape should be prepared by an installation technician.)

Tools

Crimping plier

Connection sleeve (mm)

Insulation tape

Contraction tube (mm)

Spec

MH-14

20xØ7.0(HxOD)

Width 18mm

50xØ8.0(LxOD)

Shape

 

 

 

 

1.As shown in the figure, peel off the shields from the rubber/wire of the power cable.

- Peel off 20 mm of the wire shields of the tube installed already.

• After peeling off the tube wire, you must insert a contraction tube.

2.Insert both sides of core wire of the power cable into the connection sleeve.

3.Using a compressor, compress the two points and flip it over

and compress another two points in the same location.

-The compression dimension should be 8.0.

-After compressing it, pull both sides of the wire to make sure it is firmly pressed.

4.Wrap it with the insulation tape twice and position your contraction tube in the middle of the insulation tape.

5.Apply heat to the contraction tube to contract it.

(Unit: mm)

Power cable (provided by us)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

20

 

20

60 120

180

Wire tube power cable

20

Connection sleeve

Comp. dim.

Compress it 4 times

5mm

Insulation tape

40mm Contraction tube

6. After tube contraction work is completed, wrap it with the

Insulation tape

insulation tape to finish.

 

• In case of extending the electric wire, please DO NOT use a round-shaped pressing socket. - Incomplete wire connections can cause electric shock or a fire.

42

UMG_AQ&AS18V@_IBIM_34038A_E--P14P18���������.indd 42

2013-3-18 11:00:21

Image 42
Contents English Contents Follow directions SafetAA y precautionsImportant safety symbols and precautions Wall socketFor Using For Cleaning ChecAA king before use Operation rangesMode indicator Room temperature Mode indicator Auto clean indicatorSet temperature ChecAA king the name of the partsChecAA king the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasicAA function Press the button to adjust the temperature Press the button to set the desired fan speedAdjusA ting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowPress the Set/Cancel button to active it on AA modePress the button on the remote controller Set Off timerSettinAA g the On/Off timer Press the On Timer/Off Timer buttonPress the On Timer/Off Timer button to set the time From the moment you have set the timer If the air conditioner is on If the air conditioner is offTurn off automatically Using the Smart Saver function Using the dlight Cool functionUsing the Virus Doctor function When the air conditioner is turned on UsingAA the Auto Clean functionUsing the Quiet function RunsOpening the panel Cleaning the indoor unitCleaning the outdoor unit heat exchanger Heat exchangerOpen the panel and put the Air filter out Cleaning the air filterRemoving the Air filter Dry the Air filter in a ventilated areaDeodorizing and Bio filter Close the front panelMainAA taining the air conditioner Periodical checksTroubAA leshooting Troubleshooting Flow movement changes. It is normalConnection Safety precautions General informationPower supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit  a place where the air filter can be replaced easilyWhere sulfide gas exists Outdoor UnitModel When the air outlet is towards the wall ChoosingAA the installation locationWhen installing more than 1 outdoor unit  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsConnecting the assembly cable Cable specificationConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberSmooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe PurgiAA ng the indoor unitCutting or extending the pipe Put a flare nut slightly into the pipe and modify the flareDrain hose installation Outer DiameterChanging direction of the drain hose Connect a drain hose to the drain plug Purging the connected pipesAQseries Ensure that condensation draining is adequateGas service port as seen in the picture Adding RefrigerantIf you use a pipe shorter than 4 or 5m PerfoAA rming the gas leak tests Fixing the indoor unit in placeOutdoor unit installed on the wall by rack FixinAA g the outdoor unit in placeCheck the followings Press the Mode button to select Cool modePress the Power button to stop the operation Press the Air swing button and check the followingAfter tube contraction work is completed, wrap it with AAHow to connect your extended power cablesApply heat to the contraction tube to contract it Insulation tape to finishTechnAA ical Specifications AQ18VBFUMG AQ24VBFUMGQuestions or COMMENTS? Air Conditioner