Optional accessories

The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner.

Insulated

Insulated Assembly

Insulated Assembly Pipe,

Insulated Assembly Pipe,

PE T3 Foam Tube

Vinyl Tapes (2)

Drain Plug (1)

Assembly Pipe,

Pipe, Ø9.52mm (1)

Ø12.70mm (1)

Ø15.88mm (1)

Insulation (1)

AQ

Ø6.35mm (1)

09

12/18

24

 

 

 

 

Rubber Legs (4)

Pipe Clamps A (3)

Pipe Clamps B (3)

Cement Nails (6)

M4 x 25 Tapped

Drain Hose,

Putty 100g (1)

Screws (6)

length 2m (1)

 

 

 

 

 

Foam

 

 

 

 

 

 

Insulation(1)

 

 

 

 

 

 

• If these accessories are supplied, they will be in the accessory box.

Tools required for installation

General Tools

• Vacuum Pump(Backward flowing prevention)

• Manifold Gauge

• Stud Finder

• Torque Wrench

• Pipe Cutter

• Reamer

• Pipe Bender

• Spirit Level

• Screw Driver

• Spanner

• Drill

• L Wrench

• Measuring Tape

Tools for test operations

• Thermometer

• Resistance Meter • Electroscope

Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

• Right (A)

 

Direction of pipe

 

• Left (B)

 

 

 

• Underside_right (C)

A

 

B

• Rear_right or left (D)

 

 

D

D

C

1.Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards.

Pipe hole

 

(Ø65mm)

 

A

D

B

C

30

 

(Unit : mm)

Model

A

B

C

D

09/12

27

120

68

27

18/24

34

140

68

34

Make sure to drill only one hole after choosing the direction of the pipe.

UMG_AQ&AS18V@_IBIM_34038A_E--P14P18���������.indd 30

2013-3-18 11:00:16

Image 30
Contents English Contents Follow directions SafetAA y precautionsImportant safety symbols and precautions Wall socketFor Using For Cleaning ChecAA king before use Operation rangesMode indicator Room temperature Mode indicator Auto clean indicatorSet temperature ChecAA king the name of the partsChecAA king the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasicAA function Press the button to adjust the temperature Press the button to set the desired fan speedAdjusA ting the air flow direction Using the Turbo functionPress the Air swing button on the remote controller Vertical air flowPress the Set/Cancel button to active it on AA modePress the button on the remote controller Set Off timerSettinAA g the On/Off timer Press the On Timer/Off Timer buttonPress the On Timer/Off Timer button to set the time From the moment you have set the timer If the air conditioner is on If the air conditioner is offTurn off automatically Using the Smart Saver function Using the dlight Cool functionUsing the Virus Doctor function When the air conditioner is turned on UsingAA the Auto Clean functionUsing the Quiet function RunsOpening the panel Cleaning the indoor unitCleaning the outdoor unit heat exchanger Heat exchangerOpen the panel and put the Air filter out Cleaning the air filterRemoving the Air filter Dry the Air filter in a ventilated areaDeodorizing and Bio filter Close the front panelMainAA taining the air conditioner Periodical checksTroubAA leshooting Troubleshooting Flow movement changes. It is normalConnection Safety precautions General informationPower supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit  a place where the air filter can be replaced easilyWhere sulfide gas exists Outdoor UnitModel When the air outlet is towards the wall ChoosingAA the installation locationWhen installing more than 1 outdoor unit  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsConnecting the assembly cable Cable specificationConnecting the cable Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberSmooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe PurgiAA ng the indoor unitCutting or extending the pipe Put a flare nut slightly into the pipe and modify the flareDrain hose installation Outer DiameterChanging direction of the drain hose Connect a drain hose to the drain plug Purging the connected pipesAQseries Ensure that condensation draining is adequateGas service port as seen in the picture Adding RefrigerantIf you use a pipe shorter than 4 or 5m PerfoAA rming the gas leak tests Fixing the indoor unit in placeOutdoor unit installed on the wall by rack FixinAA g the outdoor unit in placeCheck the followings Press the Mode button to select Cool modePress the Power button to stop the operation Press the Air swing button and check the followingAfter tube contraction work is completed, wrap it with AAHow to connect your extended power cablesApply heat to the contraction tube to contract it Insulation tape to finishTechnAA ical Specifications AQ18VBFUMG AQ24VBFUMGQuestions or COMMENTS? Air Conditioner