Samsung AR18NVPXCWK/MG manual Good’sleep function, Cool mode

Page 22

Energy-Saving Features

good’sleep function

Use the good'sleep function to get a good sleep at night and to save energy. You can select this function in the Cool mode.

In the Cool mode

(Select

among On, Off,

 

and

.)

 

(Set the operation time.)

Press the (Timer) button to change the current function between On, Off, and (good’sleep).

NOTE

You can adjust the set temperature by1 °C between 16 °C and 30 °C.

The recommended and optimal set temperatures in the good’sleep function are as follows:

Mode

Recommended set

Optimal set temperature

temperature

 

 

 

 

 

Cool

25 °C to 27 °C

26 °C

 

 

 

Once you start the good’sleep function, the Timer () indicator appears on the indoor unit display.

The good’sleep function can be operated with the Wind-Free Cooling function. Select the Wind-Free Cooling function to get mild breeze. To select or cancel the Wind-Free Cooling function, press the button.

You can set the operation time to between 0.5 and 12 hours. Set the operation time to 0.0 to cancel the good’sleep function.

The default operation time for the good’sleep function in the Cool mode is 8 hours. If the operation time is set to over 5 hours, the Wake up function begins 1 hour before the set time. The air conditioner stops automatically when the operation time expires.

When the Timed on, Timed off, and good'sleep functions are overlapped, the air conditioner operates its timer with only the function that you have started most recently.

If you select the good'sleep function while such functions as 2-step cooling, Fast, Comfort, Quiet, Single user function are running, these functions are cancelled.

22English

Image 22
Contents Airconditioner Contents Correct disposal of batteries in this product Failing to do so may result in electric shock or fire This may result in electric shock or fireFor Power Supply This may result in electric shock or burns Do not touch the circuit breakerwith wet handsThis may result in electric shock This may result in children seriously injuring themselvesDo not drink the water from the air conditioner Do not place objects or devices under the indoor unitDo not operate the appliance with wet hands Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfIndoor Unit Overview Room temperature sensor Inside IonizerDisplay Remote Control Overview Inserting batteriesControlling temperature Remote Control OperationOperation modes Controlling fan speed Controlling air flow directionStep cooling function Cool modeCooling Operation ComfortableWind-Free Cooling function Air Purifying Operation Dry modeDehumidifying Operation Ionizer functionFan mode Quick Smart FeaturesAuto mode Fast functionBeep sound function Comfort functionSelect Beep Quiet function Display lighting functionWi-Fi function Samsung Connect App Single userfunction Energy-Saving OperationElectricity consumption check Operation Select UsageTimed on/Timed off function Cool mode Good’sleep functionTo cancel the Auto clean operation Running Auto cleanTo deactivate the Auto clean function MethodResetting the filter-cleaning reminder Cleaning the filterDo not clean the display by using alkaline detergent Gently push the air flow blade Tip on cleaning the Wind-Free panelGently push the air flow blade Hold and pull both sides With your handTroubleshooting Problem SolutionAn error is indicated Indicator blinksCheck whether the drains are clean. Clean them regularly Sure to pass the error code to the service centre19˚C Technical Specifications27˚C 35˚CThis Wi-Fi Aircon support only below three encryption Connecting networkConnecting the wireless IP routerwith an air conditioner Downloading the Samsung Connect appLog in with a Samsung account SpecificationsRegistering Samsung account Registering your air conditioner to the Samsung Connect appControlling the air conditionerwith Samsung Connect App Troubleshooting Open Source AnnouncementSafety Information on Installation General informationPower supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyMinimum clearances for the outdoor unit Choosing the installation locationPreparation CasesIndoor unit Packing and UnpackingUnit mm Outdoor unitAccessories in the indoor unit package AccessoriesOptional accessories Tools General tools Accessories in the outdoor unit packageDrilling a hole through the wall Tools for test operationTaping the pipes, cables, and drain hose Disassembling the cover panel Indoor Unit InstallationInstallation plate Remove the cap screws, then the screwsConnecting the Power and communication cables assembly cable Optional Extending the power cable Optional Extending the drain hose Installing and connecting the drain hoseInstall the drain hose FireEach pipe when facing the wall Optional Changing the direction of the drain hoseShortening or extending the refrigerant pipes assembly pipe Pass the pipe through the hole in the wallWhen fixing the indoor unit on a wall 10 Fixing the installation plateWhen fixing the indoor unit on a window frame Fix the installation plate without inclining to one side 11 Fixing the indoor unit to the installation plateWhen fixing the indoor unit on a gypsum board 12 Assembling the cover panelRefrigerant pipes Outdoor Unit InstallationFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Cooling capacity and malfunction. Use a vacuum pumpAdding refrigerant SiphonRunning the Smart Install mode Installation InspectionPerforming the gas leak tests Motor Connector Remove foreign substance. Check Error betweenPower cable or communication Blocking error OpenPumping down for removing the product Check the following Strength of the installation sitePerforming final check and trial operation Disconnect the pipesQuestions or COMMENTS?