This appliance must be properly grounded. Do not ground the appliance to a gas pipe, plastic water pipe, or telephone line.

Failing to do so may result in electric shock, fire, and explosion.

Make sure to use a socket-outlet with ground.

CAUTION

Install your appliance on a level and hard floor that can support its weight.

• Failing to do so may result in abnormal vibrations, noise, or problems with the product.

Install the drain hose properly so that water drains correctly.

Failing to do so may result in water overflowing and property damage. Avoid adding drain to waste pipes as odours may arise in the future.

When installing the outdoor unit, make sure to connect the drain hose so that draining is performed correctly.

The water generated during heating by the outdoor unit may overflow and result in property damage.

In particular, in winter, if a block of ice falls, it may result in injury, death or property damage.

FOR POWER SUPPLY

WARNING

When the circuit breaker is damaged, contact your nearest service centre.

Do not pull or excessively bend the power line. Do not twist or tie the power line. Do not hook the power line over a metal object, place a heavy object on the power line, insert the power line between objects, or push the power line into the space behind the appliance.

This may result in electric shock or fire.

CAUTION

When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker.

• Failing to do so may result in electric shock or fire.

FOR USING

WARNING

If the appliance is flooded, please contact your nearest service centre.

• Failing to do so may result in electric shock or fire.

Safety Information

English 5

Image 5
Contents Airconditioner Contents Correct disposal of batteries in this product This may result in electric shock or fire Failing to do so may result in electric shock or fireFor Power Supply This may result in electric shock Do not touch the circuit breakerwith wet handsThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not operate the appliance with wet hands Do not place objects or devices under the indoor unitDo not drink the water from the air conditioner Do not touch the pipes connected with the productDo not clean the inside of the air conditioner by yourself For CleaningDisplay Room temperature sensor Inside IonizerIndoor Unit Overview Inserting batteries Remote Control OverviewOperation modes Remote Control OperationControlling temperature Controlling air flow direction Controlling fan speedCooling Operation Cool modeStep cooling function ComfortableWind-Free Cooling function Dehumidifying Operation Dry modeAir Purifying Operation Ionizer functionAuto mode Quick Smart FeaturesFan mode Fast functionSelect Beep Comfort functionBeep sound function Display lighting function Quiet functionWi-Fi function Samsung Connect App Electricity consumption check Energy-Saving OperationSingle userfunction Operation Select UsageTimed on/Timed off function Good’sleep function Cool modeTo deactivate the Auto clean function Running Auto cleanTo cancel the Auto clean operation MethodDo not clean the display by using alkaline detergent Cleaning the filterResetting the filter-cleaning reminder Gently push the air flow blade Hold and pull both sides Tip on cleaning the Wind-Free panelGently push the air flow blade With your handProblem Solution TroubleshootingCheck whether the drains are clean. Clean them regularly Indicator blinksAn error is indicated Sure to pass the error code to the service centre27˚C Technical Specifications19˚C 35˚CConnecting the wireless IP routerwith an air conditioner Connecting networkThis Wi-Fi Aircon support only below three encryption Downloading the Samsung Connect appRegistering Samsung account SpecificationsLog in with a Samsung account Registering your air conditioner to the Samsung Connect appControlling the air conditionerwith Samsung Connect App Open Source Announcement TroubleshootingGeneral information Safety Information on InstallationInstall the unit in a place where water can drain smoothly Power supply line, fuse, or circuit breakerPreparation Choosing the installation locationMinimum clearances for the outdoor unit CasesUnit mm Packing and UnpackingIndoor unit Outdoor unitOptional accessories AccessoriesAccessories in the indoor unit package Drilling a hole through the wall Accessories in the outdoor unit packageTools General tools Tools for test operationTaping the pipes, cables, and drain hose Installation plate Indoor Unit InstallationDisassembling the cover panel Remove the cap screws, then the screwsConnecting the Power and communication cables assembly cable Optional Extending the power cable Install the drain hose Installing and connecting the drain hoseOptional Extending the drain hose FireOptional Changing the direction of the drain hose Each pipe when facing the wallPass the pipe through the hole in the wall Shortening or extending the refrigerant pipes assembly pipeWhen fixing the indoor unit on a window frame 10 Fixing the installation plateWhen fixing the indoor unit on a wall When fixing the indoor unit on a gypsum board 11 Fixing the indoor unit to the installation plateFix the installation plate without inclining to one side 12 Assembling the cover panelFixing the outdoor unit in place Outdoor Unit InstallationRefrigerant pipes Optional Fixing the outdoor unit to a wall with a rackCooling capacity and malfunction. Use a vacuum pump Evacuating the airSiphon Adding refrigerantPerforming the gas leak tests Installation InspectionRunning the Smart Install mode Power cable or communication Error betweenMotor Connector Remove foreign substance. Check Blocking error OpenPerforming final check and trial operation Check the following Strength of the installation sitePumping down for removing the product Disconnect the pipesQuestions or COMMENTS?