Samsung AR18NVPXCWK/MG manual Outdoor Unit Installation, Fixing the outdoor unit in place

Page 48

Outdoor Unit Installation

Step 3.1 Fixing the outdoor unit in place

X

Y

Rubber leg

 

 

(Unit : mm)

 

 

 

Model

X

Y

 

 

 

**18*******

660

340

**24*******

 

 

 

 

 

1Place the outdoor unit as directed on the top of the unit to let the discharged air out properly.

2Fix the outdoor unit in level to an appropriate support using anchor bolts.

NOTE

Secure the rubber legs to help prevent the generation of noise and vibration.

If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit so that the fan can operate correctly.

Optional: Fixing the outdoor unit to a wall with a rack

Soft rubber designed to cut off vibration from rack to wall (not supplied with product)

Installation

Soft rubber designed to cut off residual vibration from outdoor unit to rack (not supplied with product)

NOTE

Make sure that the wall can support the weights of the rack and the outdoor unit.

Install the rack close to the column as much as possible.

Step 3.2 Connecting the power and communication cables and the

refrigerant pipes

L

N

 

 

F1

F2

Outdoor-to-indoor power cable

Power cable

Communication cable

(three wires)

(three wires)

(two wires)

CAUTION

Be sure to fix the power cables and communication cable with a cable clamp.

48English

Image 48
Contents Airconditioner Contents Correct disposal of batteries in this product Failing to do so may result in electric shock or fire This may result in electric shock or fireFor Power Supply Do not touch the circuit breakerwith wet hands This may result in electric shockThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not place objects or devices under the indoor unit Do not operate the appliance with wet handsDo not drink the water from the air conditioner Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfRoom temperature sensor Inside Ionizer Indoor Unit OverviewDisplay Remote Control Overview Inserting batteriesRemote Control Operation Controlling temperatureOperation modes Controlling fan speed Controlling air flow directionCool mode Cooling OperationStep cooling function ComfortableWind-Free Cooling function Dry mode Dehumidifying OperationAir Purifying Operation Ionizer functionQuick Smart Features Auto modeFan mode Fast functionComfort function Beep sound functionSelect Beep Quiet function Display lighting functionWi-Fi function Samsung Connect App Energy-Saving Operation Electricity consumption checkSingle userfunction Operation Select UsageTimed on/Timed off function Cool mode Good’sleep functionRunning Auto clean To deactivate the Auto clean functionTo cancel the Auto clean operation MethodCleaning the filter Resetting the filter-cleaning reminderDo not clean the display by using alkaline detergent Tip on cleaning the Wind-Free panel Gently push the air flow blade Hold and pull both sidesGently push the air flow blade With your handTroubleshooting Problem SolutionIndicator blinks Check whether the drains are clean. Clean them regularlyAn error is indicated Sure to pass the error code to the service centreTechnical Specifications 27˚C19˚C 35˚CConnecting network Connecting the wireless IP routerwith an air conditionerThis Wi-Fi Aircon support only below three encryption Downloading the Samsung Connect appSpecifications Registering Samsung accountLog in with a Samsung account Registering your air conditioner to the Samsung Connect appControlling the air conditionerwith Samsung Connect App Troubleshooting Open Source AnnouncementSafety Information on Installation General informationPower supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyChoosing the installation location PreparationMinimum clearances for the outdoor unit CasesPacking and Unpacking Unit mmIndoor unit Outdoor unitAccessories Accessories in the indoor unit packageOptional accessories Accessories in the outdoor unit package Drilling a hole through the wallTools General tools Tools for test operationTaping the pipes, cables, and drain hose Indoor Unit Installation Installation plateDisassembling the cover panel Remove the cap screws, then the screwsConnecting the Power and communication cables assembly cable Optional Extending the power cable Installing and connecting the drain hose Install the drain hoseOptional Extending the drain hose FireEach pipe when facing the wall Optional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Pass the pipe through the hole in the wall10 Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame 11 Fixing the indoor unit to the installation plate When fixing the indoor unit on a gypsum boardFix the installation plate without inclining to one side 12 Assembling the cover panelOutdoor Unit Installation Fixing the outdoor unit in placeRefrigerant pipes Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Cooling capacity and malfunction. Use a vacuum pumpAdding refrigerant SiphonInstallation Inspection Running the Smart Install modePerforming the gas leak tests Error between Power cable or communicationMotor Connector Remove foreign substance. Check Blocking error OpenCheck the following Strength of the installation site Performing final check and trial operationPumping down for removing the product Disconnect the pipesQuestions or COMMENTS?
Related manuals
Manual 54 pages 63.25 Kb