Samsung AR18NVPXCWK/MG Drilling a hole through the wall, Accessories in the outdoor unit package

Page 38

Installation

Accessories in the outdoor unit package

Rubber leg (4)

NOTE

A flare nut is attached to the end of each pipe of an evaporator or a service port. Use flare nuts when connecting the pipes.

Wire assembly cables are optional. If they are not supplied, use standard cables.

The drain plug and the rubber legs are included only when the air conditioner is supplied without assembly pipes.

If these accessories are supplied, they are in the accessory package or outdoor unit package.

Tools

General tools

Vacuum pump

(Backward flowing prevention)

Manifold gauge

Stud finder

Torque wrench

Pipe cutter

Reamer

Pipe bender

Spirit level

Screwdriver

Spanner

Drill

L-wrench

Measuring tape

Tools for test operation

Thermometer

Resistance meter

Electroscope

Step 1.4 Drilling a hole through the wall

Before fixing the installation plate to a wall and then fixing the indoor unit to the installation plate, a window frame, or a gypsum board, you must determine the position of a hole (with 65 mm inner diameter) through which the pipe bundle (consisting of power and communication cables, refrigerant pipes, and drain hose) will pass and then drill that hole.

1Determine the position of a 65 mm hole in consideration of the possible directions of the pipe bundle and the minimum distances between the hole and the installation plate.

Left

Right

 

Rear right or left

Bottom right

<Possible directions of the pipe bundle>

CAUTION

If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.

Pipe bundle hole

<Minimum distances between the hole and the

installation plate>

 

 

 

 

(Unit : mm)

 

 

 

 

 

Model

A

B

C

D

**18*******

33

110

110

33

**24*******

 

 

 

 

 

 

 

 

 

Pipe bundle hole: Ø 65 mm

38English

Image 38
Contents Airconditioner Contents Correct disposal of batteries in this product Failing to do so may result in electric shock or fire This may result in electric shock or fireFor Power Supply This may result in electric shock or burns Do not touch the circuit breakerwith wet handsThis may result in electric shock This may result in children seriously injuring themselvesDo not drink the water from the air conditioner Do not place objects or devices under the indoor unitDo not operate the appliance with wet hands Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfDisplay Room temperature sensor Inside IonizerIndoor Unit Overview Remote Control Overview Inserting batteriesOperation modes Remote Control OperationControlling temperature Controlling fan speed Controlling air flow directionStep cooling function Cool modeCooling Operation ComfortableWind-Free Cooling function Air Purifying Operation Dry modeDehumidifying Operation Ionizer functionFan mode Quick Smart FeaturesAuto mode Fast functionSelect Beep Comfort functionBeep sound function Quiet function Display lighting functionWi-Fi function Samsung Connect App Single userfunction Energy-Saving OperationElectricity consumption check Operation Select UsageTimed on/Timed off function Cool mode Good’sleep functionTo cancel the Auto clean operation Running Auto cleanTo deactivate the Auto clean function MethodDo not clean the display by using alkaline detergent Cleaning the filterResetting the filter-cleaning reminder Gently push the air flow blade Tip on cleaning the Wind-Free panelGently push the air flow blade Hold and pull both sides With your handTroubleshooting Problem SolutionAn error is indicated Indicator blinksCheck whether the drains are clean. Clean them regularly Sure to pass the error code to the service centre19˚C Technical Specifications27˚C 35˚CThis Wi-Fi Aircon support only below three encryption Connecting networkConnecting the wireless IP routerwith an air conditioner Downloading the Samsung Connect appLog in with a Samsung account SpecificationsRegistering Samsung account Registering your air conditioner to the Samsung Connect appControlling the air conditionerwith Samsung Connect App Troubleshooting Open Source AnnouncementSafety Information on Installation General informationPower supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothly Minimum clearances for the outdoor unit Choosing the installation location Preparation CasesIndoor unit Packing and UnpackingUnit mm Outdoor unitOptional accessories AccessoriesAccessories in the indoor unit package Tools General tools Accessories in the outdoor unit packageDrilling a hole through the wall Tools for test operationTaping the pipes, cables, and drain hose Disassembling the cover panel Indoor Unit InstallationInstallation plate Remove the cap screws, then the screwsConnecting the Power and communication cables assembly cable Optional Extending the power cable Optional Extending the drain hose Installing and connecting the drain hoseInstall the drain hose FireEach pipe when facing the wall Optional Changing the direction of the drain hoseShortening or extending the refrigerant pipes assembly pipe Pass the pipe through the hole in the wallWhen fixing the indoor unit on a window frame 10 Fixing the installation plateWhen fixing the indoor unit on a wall Fix the installation plate without inclining to one side 11 Fixing the indoor unit to the installation plateWhen fixing the indoor unit on a gypsum board 12 Assembling the cover panelRefrigerant pipes Outdoor Unit InstallationFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Cooling capacity and malfunction. Use a vacuum pumpAdding refrigerant SiphonPerforming the gas leak tests Installation InspectionRunning the Smart Install mode Motor Connector Remove foreign substance. Check Error betweenPower cable or communication Blocking error OpenPumping down for removing the product Check the following Strength of the installation sitePerforming final check and trial operation Disconnect the pipesQuestions or COMMENTS?