Samsung AR18NVPXCWK/MG manual Safety Information on Installation, General information

Page 33

Safety Information on Installation

Carefully follow the precautions listed below because they are essential to guarantee the safety of both the air conditioner and the workers.

Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components.

Verify that installation and testing operations are performed by qualified personnel.

Verify that the air conditioner is not installed in an easily accessible area.

General information

Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation.

For maximum safety, installers should always carefully read the following warnings.

Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred.

This manual explains how to install an indoor unit with a split system with two SAMSUNG units. The use of other types of units with different control systems may damage the units and invalidate the warranty. The manufacturer shall not be responsible for damages arising from the use of non compliant units.

The manufacturer shall not be responsible for damage originating from unauthorised changes or the improper connection of electric and requirements set forth in the “Operating limits” table, included in the manual, shall immediately invalidate the warranty.

The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.

Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.

In order to help prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.

Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations should be performed by qualified personnel only.

The unit contains moving parts, which should always be kept out of the reach of children.

Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorised personnel, these operations may cause electric shocks or fires.

Do not place containers with liquids or other objects on the unit.

All the materials used for the manufacture and packaging of the air conditioner are recyclable.

The packing material and exhaust batteries of the remote control (optional) must be disposed of in accordance with current laws.

The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air conditioner must be disposed of in authorised centres or returned to the retailer so that it can be disposed of correctly and safely.

Installation of the unit

IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes.

Upon receipt, inspect the product to verify that it has not been damaged during transport. If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorised technician has collected the material from the retailer.)

After completing the installation, always carry out a functional test and provide the instructions on how to operate the air conditioner to the user.

Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires, explosions or injuries.

Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs. The units’ components must be accessible and that can be disassembled in conditions of

Installation

English 33

Image 33
Contents Airconditioner Contents Correct disposal of batteries in this product This may result in electric shock or fire Failing to do so may result in electric shock or fireFor Power Supply This may result in electric shock Do not touch the circuit breakerwith wet handsThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not operate the appliance with wet hands Do not place objects or devices under the indoor unitDo not drink the water from the air conditioner Do not touch the pipes connected with the productDo not clean the inside of the air conditioner by yourself For CleaningRoom temperature sensor Inside Ionizer Indoor Unit OverviewDisplay Inserting batteries Remote Control OverviewRemote Control Operation Controlling temperatureOperation modes Controlling air flow direction Controlling fan speedCooling Operation Cool modeStep cooling function ComfortableWind-Free Cooling function Dehumidifying Operation Dry modeAir Purifying Operation Ionizer functionAuto mode Quick Smart FeaturesFan mode Fast functionComfort function Beep sound functionSelect Beep Display lighting function Quiet functionWi-Fi function Samsung Connect App Electricity consumption check Energy-Saving OperationSingle userfunction Operation Select UsageTimed on/Timed off function Good’sleep function Cool modeTo deactivate the Auto clean function Running Auto cleanTo cancel the Auto clean operation MethodCleaning the filter Resetting the filter-cleaning reminderDo not clean the display by using alkaline detergent Gently push the air flow blade Hold and pull both sides Tip on cleaning the Wind-Free panelGently push the air flow blade With your handProblem Solution TroubleshootingCheck whether the drains are clean. Clean them regularly Indicator blinksAn error is indicated Sure to pass the error code to the service centre27˚C Technical Specifications19˚C 35˚CConnecting the wireless IP routerwith an air conditioner Connecting networkThis Wi-Fi Aircon support only below three encryption Downloading the Samsung Connect appRegistering Samsung account SpecificationsLog in with a Samsung account Registering your air conditioner to the Samsung Connect appControlling the air conditionerwith Samsung Connect App Open Source Announcement TroubleshootingGeneral information Safety Information on InstallationInstall the unit in a place where water can drain smoothly Power supply line, fuse, or circuit breakerPreparation Choosing the installation locationMinimum clearances for the outdoor unit CasesUnit mm Packing and UnpackingIndoor unit Outdoor unitAccessories Accessories in the indoor unit packageOptional accessories Drilling a hole through the wall Accessories in the outdoor unit packageTools General tools Tools for test operationTaping the pipes, cables, and drain hose Installation plate Indoor Unit InstallationDisassembling the cover panel Remove the cap screws, then the screwsConnecting the Power and communication cables assembly cable Optional Extending the power cable Install the drain hose Installing and connecting the drain hoseOptional Extending the drain hose FireOptional Changing the direction of the drain hose Each pipe when facing the wallPass the pipe through the hole in the wall Shortening or extending the refrigerant pipes assembly pipe10 Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum board 11 Fixing the indoor unit to the installation plateFix the installation plate without inclining to one side 12 Assembling the cover panelFixing the outdoor unit in place Outdoor Unit InstallationRefrigerant pipes Optional Fixing the outdoor unit to a wall with a rackCooling capacity and malfunction. Use a vacuum pump Evacuating the airSiphon Adding refrigerantInstallation Inspection Running the Smart Install modePerforming the gas leak tests Power cable or communication Error betweenMotor Connector Remove foreign substance. Check Blocking error OpenPerforming final check and trial operation Check the following Strength of the installation sitePumping down for removing the product Disconnect the pipesQuestions or COMMENTS?
Related manuals
Manual 54 pages 63.25 Kb