Samsung AR18NVPXCWK/MG manual Installation Inspection, Running the Smart Install mode

Page 51

Installation Inspection

Step 4.1 Performing the gas leak tests

1Before inspecting the leakage, use a torque wrench to close the cap for the stop valve. (Comply with a tightening torque for each size of the diameter, and tighten the cap firmly to prevent any leakage.)

Tightening torque for body cap (Refer to the table)

Charging core

Spindle

R-22: Thread of the screw - 7/16-2OUNF

R-410A: Thread of the screw -1/2-2OUNF

Tightening torque for charging port cap (Refer to the table)

Outer diameter

Tightening torque

(mm)

Body cap (N•m)

Charging port cap (N•m)

 

 

 

 

ø 6.35

20 to 25

 

 

 

 

ø 9.52

20 to 25

 

 

 

 

ø 12.70

25 to 30

10 to 12

 

 

 

ø 15.88

30 to 35

 

 

 

 

Over ø 19.05

35 to 40

 

 

 

 

( 1 N•m = 10 kgf•cm )

2Insert inert gas into the pipes connected to indoor and outdoor units.

3Test leakage on the connection parts of the indoor and outdoor units with soap lather or liquid.

Test parts for the indoor unit

Test parts for the indoor unit

Step 4.2 Running the Smart Install mode

1Make sure that the air conditioner is in the standby status.

2Hold down the (Power), (Mode), and

(SET / Temperature type ()) buttons on the remote control simultaneously for 4 seconds.

3Wait until Smart Install mode succeeds or fails. It takes approximately 7 to 13 minutes.

• While Smart Install mode is proceeding:

Type

Display

LED Display

 

 

LED1

 

 

LED2

 

 

LED3

Indoor

 

 

unit

The progress is

The LEDs on the

indicator

indoor unit display

 

displayed as a

blink in sequence,

 

number between

 

then all of them

 

0 and 99 on

 

blink simultaneously.

 

the indoor unit

 

These operations

 

display.

 

repeat.

 

 

When Smart Install mode succeeds: Smart Install mode ends with ringing sound, and the air conditioner is in standby status.

When Smart Install mode fails: An error message is displayed on the indoor unit display, and Smart Install mode ends.

NOTE

Smart Install mode can be operated only with the supplied remote control.

During the Smart install mode procedure, remote control cannot be operated.

Installation

English 51

Image 51
Contents Airconditioner Contents Correct disposal of batteries in this product This may result in electric shock or fire Failing to do so may result in electric shock or fireFor Power Supply This may result in children seriously injuring themselves Do not touch the circuit breakerwith wet handsThis may result in electric shock This may result in electric shock or burnsDo not touch the pipes connected with the product Do not place objects or devices under the indoor unitDo not operate the appliance with wet hands Do not drink the water from the air conditionerDo not clean the inside of the air conditioner by yourself For CleaningRoom temperature sensor Inside Ionizer Indoor Unit OverviewDisplay Inserting batteries Remote Control OverviewRemote Control Operation Controlling temperatureOperation modes Controlling air flow direction Controlling fan speedComfortable Cool modeCooling Operation Step cooling functionWind-Free Cooling function Ionizer function Dry modeDehumidifying Operation Air Purifying OperationFast function Quick Smart FeaturesAuto mode Fan modeComfort function Beep sound functionSelect Beep Display lighting function Quiet functionWi-Fi function Samsung Connect App Operation Select Usage Energy-Saving OperationElectricity consumption check Single userfunctionTimed on/Timed off function Good’sleep function Cool modeMethod Running Auto cleanTo deactivate the Auto clean function To cancel the Auto clean operationCleaning the filter Resetting the filter-cleaning reminderDo not clean the display by using alkaline detergent With your hand Tip on cleaning the Wind-Free panelGently push the air flow blade Hold and pull both sides Gently push the air flow bladeProblem Solution TroubleshootingSure to pass the error code to the service centre Indicator blinksCheck whether the drains are clean. Clean them regularly An error is indicated35˚C Technical Specifications27˚C 19˚CDownloading the Samsung Connect app Connecting networkConnecting the wireless IP routerwith an air conditioner This Wi-Fi Aircon support only below three encryptionRegistering your air conditioner to the Samsung Connect app SpecificationsRegistering Samsung account Log in with a Samsung accountControlling the air conditionerwith Samsung Connect App Open Source Announcement TroubleshootingGeneral information Safety Information on InstallationInstall the unit in a place where water can drain smoothly Power supply line, fuse, or circuit breakerCases Choosing the installation locationPreparation Minimum clearances for the outdoor unitOutdoor unit Packing and UnpackingUnit mm Indoor unitAccessories Accessories in the indoor unit packageOptional accessories Tools for test operation Accessories in the outdoor unit packageDrilling a hole through the wall Tools General toolsTaping the pipes, cables, and drain hose Remove the cap screws, then the screws Indoor Unit InstallationInstallation plate Disassembling the cover panelConnecting the Power and communication cables assembly cable Optional Extending the power cable Fire Installing and connecting the drain hoseInstall the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Each pipe when facing the wallPass the pipe through the hole in the wall Shortening or extending the refrigerant pipes assembly pipe10 Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame 12 Assembling the cover panel 11 Fixing the indoor unit to the installation plateWhen fixing the indoor unit on a gypsum board Fix the installation plate without inclining to one side Optional Fixing the outdoor unit to a wall with a rack Outdoor Unit Installation Fixing the outdoor unit in place Refrigerant pipesCooling capacity and malfunction. Use a vacuum pump Evacuating the airSiphon Adding refrigerantInstallation Inspection Running the Smart Install modePerforming the gas leak tests Blocking error Open Error betweenPower cable or communication Motor Connector Remove foreign substance. CheckDisconnect the pipes Check the following Strength of the installation sitePerforming final check and trial operation Pumping down for removing the productQuestions or COMMENTS?