CAUTION

If you need a pipe longer than specified in piping codes and standards, you must add refrigerant to the pipe. Otherwise, the indoor unit may freeze.

While removing burrs, put the pipe face down to make sure that the burrs do not get in to the pipe.

Step 2.10 Fixing the installation plate

You can install the indoor unit on a wall, window frame, or gypsum board.

WARNING

Make sure that the wall, window frame, or gypsum board can withstand the weight of the indoor unit. If you install the indoor unit in a place where it is not strong enough to withstand the unit's weight, the unit could fall and cause injury.

Liquid service port

Gas service port

<High pressure>

<Low pressure>

When fixing the indoor unit on a wall

Fix the installation plate to the wall giving attention to the weight of the indoor unit.

Plastic anchor

Installation

 

 

Correct

 

Inclined

Cracked

Uneven

Damaged

 

 

thickness

surface

<Flare nut>

NOTE

Excessive torque may cause gas leakage. When extending the pipe with welding or brazing, ensure that nitrogen is used during the welding or brazing process. The joint must be accessible and serviceable.

CAUTION

Tighten the flare nut at the specified torque. If the flare nut is over-tightened, it may break to cause leakage of refrigerant gas.

20 mm

Wall

 

 

(Unit : mm)

Model

A

B

C

D

**18*******

33

110

110

33

**24*******

 

 

 

 

 

 

 

 

 

 

Pipe bundle hole: Ø 65 mm

NOTE

If you mount the plate to a concrete wall using plastic anchors, make sure that gaps between the wall and the plate, created by projected anchor, is less than 20 mm.

When fixing the indoor unit on a window frame

1Determine the positions of the wooden uprights to be attached to the window frame.

2Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.

3Attach the installation plate to the wooden upright using tapping screws.

46English

Image 46
Contents Airconditioner Contents Correct disposal of batteries in this product Failing to do so may result in electric shock or fire This may result in electric shock or fireFor Power Supply This may result in electric shock or burns Do not touch the circuit breakerwith wet handsThis may result in electric shock This may result in children seriously injuring themselvesDo not drink the water from the air conditioner Do not place objects or devices under the indoor unitDo not operate the appliance with wet hands Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfIndoor Unit Overview Room temperature sensor Inside IonizerDisplay Remote Control Overview Inserting batteriesControlling temperature Remote Control OperationOperation modes Controlling fan speed Controlling air flow directionStep cooling function Cool modeCooling Operation ComfortableWind-Free Cooling function Air Purifying Operation Dry modeDehumidifying Operation Ionizer functionFan mode Quick Smart FeaturesAuto mode Fast functionBeep sound function Comfort functionSelect Beep Quiet function Display lighting functionWi-Fi function Samsung Connect App Single userfunction Energy-Saving OperationElectricity consumption check Operation Select UsageTimed on/Timed off function Cool mode Good’sleep functionTo cancel the Auto clean operation Running Auto cleanTo deactivate the Auto clean function MethodResetting the filter-cleaning reminder Cleaning the filterDo not clean the display by using alkaline detergent Gently push the air flow blade Tip on cleaning the Wind-Free panelGently push the air flow blade Hold and pull both sides With your handTroubleshooting Problem SolutionAn error is indicated Indicator blinksCheck whether the drains are clean. Clean them regularly Sure to pass the error code to the service centre19˚C Technical Specifications27˚C 35˚CThis Wi-Fi Aircon support only below three encryption Connecting networkConnecting the wireless IP routerwith an air conditioner Downloading the Samsung Connect appLog in with a Samsung account SpecificationsRegistering Samsung account Registering your air conditioner to the Samsung Connect appControlling the air conditionerwith Samsung Connect App Troubleshooting Open Source AnnouncementSafety Information on Installation General informationPower supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyMinimum clearances for the outdoor unit Choosing the installation locationPreparation CasesIndoor unit Packing and UnpackingUnit mm Outdoor unitAccessories in the indoor unit package AccessoriesOptional accessories Tools General tools Accessories in the outdoor unit packageDrilling a hole through the wall Tools for test operationTaping the pipes, cables, and drain hose Disassembling the cover panel Indoor Unit InstallationInstallation plate Remove the cap screws, then the screwsConnecting the Power and communication cables assembly cable Optional Extending the power cable Optional Extending the drain hose Installing and connecting the drain hose Install the drain hose FireEach pipe when facing the wall Optional Changing the direction of the drain hoseShortening or extending the refrigerant pipes assembly pipe Pass the pipe through the hole in the wallWhen fixing the indoor unit on a wall 10 Fixing the installation plateWhen fixing the indoor unit on a window frame Fix the installation plate without inclining to one side 11 Fixing the indoor unit to the installation plateWhen fixing the indoor unit on a gypsum board 12 Assembling the cover panelRefrigerant pipes Outdoor Unit InstallationFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Cooling capacity and malfunction. Use a vacuum pumpAdding refrigerant SiphonRunning the Smart Install mode Installation InspectionPerforming the gas leak tests Motor Connector Remove foreign substance. Check Error betweenPower cable or communication Blocking error OpenPumping down for removing the product Check the following Strength of the installation sitePerforming final check and trial operation Disconnect the pipesQuestions or COMMENTS?