Samsung AR18NVPXCWK/MG manual Shortening or extending the refrigerant pipes assembly pipe

Page 45

Outer diameter (mm)

Torque (N•m)

Torque (kgf•cm)

 

 

 

ø 6.35

14 to 18

140 to 180

 

 

 

ø 9.52

34 to 42

350 to 430

 

 

 

ø 12.70

49 to 61

500 to 620

 

 

 

ø 15.88

68 to 82

690 to 830

 

 

 

NOTE

If you want to shorten or extend the pipes, see Step 2.9 Shortening or extending the refrigerant pipes (assembly pipe) on page 45.

4Cut off the remaining foam insulation.

5If necessary, bend the pipe to fit along the bottom of the indoor unit. Then pull it out through the appropriate hole.

The pipe should not project from the rear of the indoor unit.

The bending radius should be 100 mm or more.

6Pass the pipe through the hole in the wall.

7Fix the indoor unit on the wall.Pass the cables, pipes and hose through the knock-out hole which would be connected to the outdoor unit .

8Use 2 screws to fix the indoor unit as shown in the picture 2.

9Assemble the Guide into the position of A or B as shown in the picture 3.

NOTE

The pipe will be insulated and fixed permanently into position after finishing the installation and the gas leak test. For further details. see Step 4.1 Performing the gas leak tests on page 51.

CAUTION

Tighten the flare nut with a torque wrench according to specified method. If the flare nut is over-tightened, the flare may break and cause refrigerant gas leakage.

Do not box in or cover the pipe connection.

All refrigerant pipe connection must be easily accessible and serviceable.

Step 2.9 Shortening or extending the refrigerant pipes (assembly pipe)

 

 

Pipe cutter

 

 

 

Pipe

 

90°

Oblique

Rough

Burr

D

 

90°±2°

 

 

 

A

45°±2°

 

 

 

 

L

 

 

R 0.4 to 0.8

Pipe

Flare

D

 

 

 

 

(Unit: mm)

Outer diameter (D)

Depth (A) Flare dimension (L)

ø 6.35

1.3

8.7 to 9.1

ø 9.52

1.8

12.8 to 13.2

ø 12.70

2.0

16.2 to 16.6

ø 15.88

2.2

19.3 to 19.7

 

 

Flare nut

Indoor outlet pipe

Connecting pipe

Outer diameter (mm) Torque (N•m)

Torque (kgf•cm)

ø 6.35

14 to 18

140 to 180

ø 9.52

34 to 42

350 to 430

ø 12.70

49 to 61

500 to 620

ø 15.88

68 to 82

690 to 830

Installation

English 45

Image 45
Contents Airconditioner Contents Correct disposal of batteries in this product This may result in electric shock or fire Failing to do so may result in electric shock or fireFor Power Supply This may result in electric shock Do not touch the circuit breakerwith wet handsThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not operate the appliance with wet hands Do not place objects or devices under the indoor unitDo not drink the water from the air conditioner Do not touch the pipes connected with the productDo not clean the inside of the air conditioner by yourself For CleaningRoom temperature sensor Inside Ionizer Indoor Unit OverviewDisplay Inserting batteries Remote Control OverviewRemote Control Operation Controlling temperatureOperation modes Controlling air flow direction Controlling fan speedCooling Operation Cool modeStep cooling function ComfortableWind-Free Cooling function Dehumidifying Operation Dry modeAir Purifying Operation Ionizer functionAuto mode Quick Smart FeaturesFan mode Fast functionComfort function Beep sound functionSelect Beep Display lighting function Quiet functionWi-Fi function Samsung Connect App Electricity consumption check Energy-Saving OperationSingle userfunction Operation Select UsageTimed on/Timed off function Good’sleep function Cool modeTo deactivate the Auto clean function Running Auto cleanTo cancel the Auto clean operation MethodCleaning the filter Resetting the filter-cleaning reminderDo not clean the display by using alkaline detergent Gently push the air flow blade Hold and pull both sides Tip on cleaning the Wind-Free panelGently push the air flow blade With your handProblem Solution TroubleshootingCheck whether the drains are clean. Clean them regularly Indicator blinksAn error is indicated Sure to pass the error code to the service centre27˚C Technical Specifications19˚C 35˚CConnecting the wireless IP routerwith an air conditioner Connecting networkThis Wi-Fi Aircon support only below three encryption Downloading the Samsung Connect appRegistering Samsung account SpecificationsLog in with a Samsung account Registering your air conditioner to the Samsung Connect appControlling the air conditionerwith Samsung Connect App Open Source Announcement TroubleshootingGeneral information Safety Information on InstallationInstall the unit in a place where water can drain smoothly Power supply line, fuse, or circuit breakerPreparation Choosing the installation locationMinimum clearances for the outdoor unit CasesUnit mm Packing and UnpackingIndoor unit Outdoor unitAccessories Accessories in the indoor unit packageOptional accessories Drilling a hole through the wall Accessories in the outdoor unit packageTools General tools Tools for test operationTaping the pipes, cables, and drain hose Installation plate Indoor Unit InstallationDisassembling the cover panel Remove the cap screws, then the screwsConnecting the Power and communication cables assembly cable Optional Extending the power cable Install the drain hose Installing and connecting the drain hoseOptional Extending the drain hose FireOptional Changing the direction of the drain hose Each pipe when facing the wallPass the pipe through the hole in the wall Shortening or extending the refrigerant pipes assembly pipe10 Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum board 11 Fixing the indoor unit to the installation plateFix the installation plate without inclining to one side 12 Assembling the cover panelFixing the outdoor unit in place Outdoor Unit InstallationRefrigerant pipes Optional Fixing the outdoor unit to a wall with a rackCooling capacity and malfunction. Use a vacuum pump Evacuating the airSiphon Adding refrigerantInstallation Inspection Running the Smart Install modePerforming the gas leak tests Power cable or communication Error betweenMotor Connector Remove foreign substance. Check Blocking error OpenPerforming final check and trial operation Check the following Strength of the installation sitePumping down for removing the product Disconnect the pipesQuestions or COMMENTS?