Samsung AR18NVPXCWK/MG manual Communication, Error between, Power cable or communication

Page 52

Installation

When error occurs, take necessary measures by referring to the following table. For more information on necessary measures for errors, refer to the service manual.

Error indicator

 

 

 

 

 

 

LED Display

Error

Measures for the installer to take

Display

LED 1

LED 2

LED 3

 

 

 

 

 

 

/ /

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Communication

• Check the connection wire between

 

 

 

 

 

error between

the indoor and outdoor units (whether

 

 

 

 

 

indoor and outdoor

the power cable or communication

 

 

 

 

 

units

cable is crossed or not).

 

 

 

 

 

 

 

 

 

 

 

 

Error on indoor

• Check the connection of the

 

 

 

 

 

temperature

connector.

 

 

 

 

 

sensor

 

 

 

 

 

 

 

 

,

 

 

 

 

Error on indoor

• Check the connection of the

 

 

 

 

 

heat exchanger

connector.

 

 

 

 

 

 

 

 

 

 

 

 

Error on indoor fan

• Check the connection of the

 

 

 

 

 

motor

connector.

 

 

 

 

 

 

• Remove foreign substance. (Check

 

 

 

 

 

 

for the cause that restrains motor.)

 

 

 

 

 

 

 

display

 

 

 

 

EEPROM/Option

Re-set options.

and all LEDs

 

 

 

 

error

 

blink.

 

 

 

 

 

 

 

 

 

 

 

 

 

,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant flow

• Check if the stop valve is completely

 

 

 

 

 

blocking error

open.

 

 

 

 

 

 

• Check if there is any blockage in the

 

 

 

 

 

 

refrigerant pipe which connects the

 

 

 

 

 

 

indoor and outdoor units.

 

 

 

 

 

 

• Check for refrigerant leak.

 

 

 

 

 

 

 

 

 

 

 

 

Lack of refrigerant

• Check if a sufficient amount of

 

 

 

 

 

(for inverter

refrigerant is additionally charged

 

 

 

 

 

 

This LED pattern

models only)

for the pipe longer than specified in

 

 

piping codes and standards.

 

 

appears when an

 

 

 

 

• Check for refrigerant leak between

 

 

error occurs on the

 

 

 

outdoor unit.

 

valve and pipe connection.

 

 

 

 

 

 

 

: Off, : Blinking, : On

52English

Image 52
Contents Airconditioner Contents Correct disposal of batteries in this product Failing to do so may result in electric shock or fire This may result in electric shock or fireFor Power Supply Do not touch the circuit breakerwith wet hands This may result in electric shockThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not place objects or devices under the indoor unit Do not operate the appliance with wet handsDo not drink the water from the air conditioner Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfIndoor Unit Overview Room temperature sensor Inside IonizerDisplay Remote Control Overview Inserting batteriesControlling temperature Remote Control OperationOperation modes Controlling fan speed Controlling air flow directionCool mode Cooling OperationStep cooling function ComfortableWind-Free Cooling function Dry mode Dehumidifying OperationAir Purifying Operation Ionizer functionQuick Smart Features Auto modeFan mode Fast functionBeep sound function Comfort functionSelect Beep Quiet function Display lighting functionWi-Fi function Samsung Connect App Energy-Saving Operation Electricity consumption checkSingle userfunction Operation Select UsageTimed on/Timed off function Cool mode Good’sleep functionRunning Auto clean To deactivate the Auto clean functionTo cancel the Auto clean operation MethodResetting the filter-cleaning reminder Cleaning the filterDo not clean the display by using alkaline detergent Tip on cleaning the Wind-Free panel Gently push the air flow blade Hold and pull both sidesGently push the air flow blade With your handTroubleshooting Problem SolutionIndicator blinks Check whether the drains are clean. Clean them regularlyAn error is indicated Sure to pass the error code to the service centreTechnical Specifications 27˚C19˚C 35˚CConnecting network Connecting the wireless IP routerwith an air conditionerThis Wi-Fi Aircon support only below three encryption Downloading the Samsung Connect appSpecifications Registering Samsung accountLog in with a Samsung account Registering your air conditioner to the Samsung Connect appControlling the air conditionerwith Samsung Connect App Troubleshooting Open Source AnnouncementSafety Information on Installation General informationPower supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyChoosing the installation location PreparationMinimum clearances for the outdoor unit CasesPacking and Unpacking Unit mmIndoor unit Outdoor unitAccessories in the indoor unit package AccessoriesOptional accessories Accessories in the outdoor unit package Drilling a hole through the wallTools General tools Tools for test operationTaping the pipes, cables, and drain hose Indoor Unit Installation Installation plateDisassembling the cover panel Remove the cap screws, then the screwsConnecting the Power and communication cables assembly cable Optional Extending the power cable Installing and connecting the drain hose Install the drain hoseOptional Extending the drain hose FireEach pipe when facing the wall Optional Changing the direction of the drain hoseShortening or extending the refrigerant pipes assembly pipe Pass the pipe through the hole in the wallWhen fixing the indoor unit on a wall 10 Fixing the installation plateWhen fixing the indoor unit on a window frame 11 Fixing the indoor unit to the installation plate When fixing the indoor unit on a gypsum boardFix the installation plate without inclining to one side 12 Assembling the cover panelOutdoor Unit Installation Fixing the outdoor unit in placeRefrigerant pipes Optional Fixing the outdoor unit to a wall with a rack Evacuating the air Cooling capacity and malfunction. Use a vacuum pumpAdding refrigerant SiphonRunning the Smart Install mode Installation InspectionPerforming the gas leak tests Error between Power cable or communicationMotor Connector Remove foreign substance. Check Blocking error OpenCheck the following Strength of the installation site Performing final check and trial operationPumping down for removing the product Disconnect the pipesQuestions or COMMENTS?