Step 4.3 Performing final check and trial operation

1Check the following:

Strength of the installation site

Tightness of pipe connection to detect gas leak

Electric wiring connection

Heat-resistant insulation of the pipe

Drainage

Grounding conductor connection

Correct operation (Take the following steps.)

2Press the (Power) button on the remote control to check the following:

The indicator on the indoor unit lights up.

The airflow blade opens and the fan gears up for operation.

3Press the (Mode) button to select Cool mode. Then take the following sub-steps:

In Cool mode, use the Temperature button to set the set temperature to 16 °C.

Check whether, approximately 3 to 5 minutes later, the outdoor unit starts, and a cool air blows out.

After12 minutes of stationary condition, check the indoor unit air treatment.

4Press the (Air swing) button to check whether the airflow blades work properly.

5Press the (Power) button to stop the trial operation.

Pumping down for removing the product

Pump-down is an operation intended to collect all the system refrigerant in the outdoor unit. This operation must be carried out before disconnecting the refrigerant tubing in order to avoid refrigerant loss to the atmosphere.

WARNING

After installing the product, be sure to perform leak tests on the piping connections. After pumping down refrigerant to inspect or relocate the outdoor unit, be sure to stop the compressor and then remove the connected pipes.

–– Do not operate the compressor while a valve is open due to refrigerant leakage from a pipe or an unconnected or incorrectly connected pipe. Failure to do so may cause air to flow into the compressor and too a high pressure to develop inside the refrigerant circuit, leading to an explosion or product malfunction.

1Hold down the (Power) button on the indoor unit for

5 seconds. Beep sounds immediately to indicate that the

product is ready for pump down procedure.

2Let the compressor run for more than 5 minutes.

3Release the valve caps on High and Low pressure side.

4Use L-wrench to close the valve on the high pressure side.

5After approximately1 minute, close the valve on the low pressure side.

6Stop operation of the air conditioner by pressing the

(Power) button on the indoor unit or remote control.

7Disconnect the pipes.

CAUTION

Compressor damage may occur if the compressor is run at a negative suction pressure.

 

1

 

1 minute

Liquid service port

Gas service port

<High pressure>

<Low pressure>

2

Off

Installation

English 53

Image 53
Contents Airconditioner Contents Correct disposal of batteries in this product This may result in electric shock or fire Failing to do so may result in electric shock or fireFor Power Supply This may result in electric shock Do not touch the circuit breakerwith wet handsThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not operate the appliance with wet hands Do not place objects or devices under the indoor unitDo not drink the water from the air conditioner Do not touch the pipes connected with the productDo not clean the inside of the air conditioner by yourself For CleaningDisplay Room temperature sensor Inside IonizerIndoor Unit Overview Inserting batteries Remote Control OverviewOperation modes Remote Control OperationControlling temperature Controlling air flow direction Controlling fan speedCooling Operation Cool modeStep cooling function ComfortableWind-Free Cooling function Dehumidifying Operation Dry modeAir Purifying Operation Ionizer functionAuto mode Quick Smart FeaturesFan mode Fast functionSelect Beep Comfort functionBeep sound function Display lighting function Quiet functionWi-Fi function Samsung Connect App Electricity consumption check Energy-Saving OperationSingle userfunction Operation Select UsageTimed on/Timed off function Good’sleep function Cool modeTo deactivate the Auto clean function Running Auto cleanTo cancel the Auto clean operation MethodDo not clean the display by using alkaline detergent Cleaning the filterResetting the filter-cleaning reminder Gently push the air flow blade Hold and pull both sides Tip on cleaning the Wind-Free panelGently push the air flow blade With your handProblem Solution TroubleshootingCheck whether the drains are clean. Clean them regularly Indicator blinksAn error is indicated Sure to pass the error code to the service centre27˚C Technical Specifications19˚C 35˚CConnecting the wireless IP routerwith an air conditioner Connecting networkThis Wi-Fi Aircon support only below three encryption Downloading the Samsung Connect appRegistering Samsung account SpecificationsLog in with a Samsung account Registering your air conditioner to the Samsung Connect appControlling the air conditionerwith Samsung Connect App Open Source Announcement TroubleshootingGeneral information Safety Information on InstallationInstall the unit in a place where water can drain smoothly Power supply line, fuse, or circuit breakerPreparation Choosing the installation locationMinimum clearances for the outdoor unit CasesUnit mm Packing and UnpackingIndoor unit Outdoor unitOptional accessories AccessoriesAccessories in the indoor unit package Drilling a hole through the wall Accessories in the outdoor unit packageTools General tools Tools for test operationTaping the pipes, cables, and drain hose Installation plate Indoor Unit InstallationDisassembling the cover panel Remove the cap screws, then the screwsConnecting the Power and communication cables assembly cable Optional Extending the power cable Install the drain hose Installing and connecting the drain hoseOptional Extending the drain hose FireOptional Changing the direction of the drain hose Each pipe when facing the wallPass the pipe through the hole in the wall Shortening or extending the refrigerant pipes assembly pipeWhen fixing the indoor unit on a window frame 10 Fixing the installation plateWhen fixing the indoor unit on a wall When fixing the indoor unit on a gypsum board 11 Fixing the indoor unit to the installation plateFix the installation plate without inclining to one side 12 Assembling the cover panelFixing the outdoor unit in place Outdoor Unit InstallationRefrigerant pipes Optional Fixing the outdoor unit to a wall with a rackCooling capacity and malfunction. Use a vacuum pump Evacuating the air Siphon Adding refrigerantPerforming the gas leak tests Installation InspectionRunning the Smart Install mode Power cable or communication Error betweenMotor Connector Remove foreign substance. Check Blocking error OpenPerforming final check and trial operation Check the following Strength of the installation sitePumping down for removing the product Disconnect the pipesQuestions or COMMENTS?