Samsung AR18NVPXCWK/MG manual Packing and Unpacking, Unit mm, Indoor unit, Outdoor unit

Page 36

Installation

When installing more than 1 outdoor unit

(5 cases)

 

 

 

 

 

(Unit: mm)

1500

600

3000

3000

200

 

 

 

 

300

 

 

600

 

600

1500

 

 

 

 

 

1500

 

 

 

 

 

 

300

300

600

600

600

 

 

 

500

300

 

 

 

 

 

 

 

 

 

500

300

 

 

 

 

 

 

 

 

CAUTION

If the outdoor unit is installed with any insufficient clearance, it may generate sound and affect the whole product.

Be sure to install the outdoor unit in a level place where its vibration does not affect the whole product.

Step 1.2 Packing and Unpacking

Indoor unit

Packing the unit as below procedure

1Put the indoor unit onto the packing case.

2Assemble cushion-both side of indoor unit. (Left and Right)

3Seal the packing case.

Unpacking the unit as below procedure

1Open the packing case.

2Take out the both side of cushion(Left and Right).

3Move the set from the packing case.

Outdoor unit

Packing the unit as below procedure

1Put the outdoor unit onto the cushion-bottom.

2Put the cushion-top onto the outdoor unit

3Put the packing case from the top of set.

4Seal the packing case.

Unpacking the unit as below procedure

1Take out the packing case from the set.

2Take out the cushion-top.

3Move the set from the cushion-bottom.

36English

Image 36
Contents Airconditioner Contents Correct disposal of batteries in this product Failing to do so may result in electric shock or fire This may result in electric shock or fireFor Power Supply Do not touch the circuit breakerwith wet hands This may result in electric shockThis may result in electric shock or burns This may result in children seriously injuring themselvesDo not place objects or devices under the indoor unit Do not operate the appliance with wet handsDo not drink the water from the air conditioner Do not touch the pipes connected with the productFor Cleaning Do not clean the inside of the air conditioner by yourselfRoom temperature sensor Inside Ionizer Indoor Unit OverviewDisplay Remote Control Overview Inserting batteriesRemote Control Operation Controlling temperatureOperation modes Controlling fan speed Controlling air flow directionCool mode Cooling OperationStep cooling function ComfortableWind-Free Cooling function Dry mode Dehumidifying OperationAir Purifying Operation Ionizer functionQuick Smart Features Auto modeFan mode Fast functionComfort function Beep sound functionSelect Beep Quiet function Display lighting functionWi-Fi function Samsung Connect App Energy-Saving Operation Electricity consumption checkSingle userfunction Operation Select UsageTimed on/Timed off function Cool mode Good’sleep functionRunning Auto clean To deactivate the Auto clean functionTo cancel the Auto clean operation MethodCleaning the filter Resetting the filter-cleaning reminderDo not clean the display by using alkaline detergent Tip on cleaning the Wind-Free panel Gently push the air flow blade Hold and pull both sidesGently push the air flow blade With your handTroubleshooting Problem SolutionIndicator blinks Check whether the drains are clean. Clean them regularlyAn error is indicated Sure to pass the error code to the service centreTechnical Specifications 27˚C19˚C 35˚CConnecting network Connecting the wireless IP routerwith an air conditionerThis Wi-Fi Aircon support only below three encryption Downloading the Samsung Connect appSpecifications Registering Samsung accountLog in with a Samsung account Registering your air conditioner to the Samsung Connect appControlling the air conditionerwith Samsung Connect App Troubleshooting Open Source Announcement Safety Information on Installation General informationPower supply line, fuse, or circuit breaker Install the unit in a place where water can drain smoothlyChoosing the installation location PreparationMinimum clearances for the outdoor unit CasesPacking and Unpacking Unit mmIndoor unit Outdoor unitAccessories Accessories in the indoor unit packageOptional accessories Accessories in the outdoor unit package Drilling a hole through the wallTools General tools Tools for test operationTaping the pipes, cables, and drain hose Indoor Unit Installation Installation plateDisassembling the cover panel Remove the cap screws, then the screwsConnecting the Power and communication cables assembly cable Optional Extending the power cable Installing and connecting the drain hose Install the drain hoseOptional Extending the drain hose FireEach pipe when facing the wall Optional Changing the direction of the drain hoseShortening or extending the refrigerant pipes assembly pipe Pass the pipe through the hole in the wall10 Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame 11 Fixing the indoor unit to the installation plate When fixing the indoor unit on a gypsum boardFix the installation plate without inclining to one side 12 Assembling the cover panelOutdoor Unit Installation Fixing the outdoor unit in placeRefrigerant pipes Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Cooling capacity and malfunction. Use a vacuum pumpAdding refrigerant SiphonInstallation Inspection Running the Smart Install modePerforming the gas leak tests Error between Power cable or communicationMotor Connector Remove foreign substance. Check Blocking error OpenCheck the following Strength of the installation site Performing final check and trial operationPumping down for removing the product Disconnect the pipesQuestions or COMMENTS?