Samsung AR18HVFSEWKNMG Remote controller display, Low Battery warning, Inserting the batteries

Page 14

Remote controller display

Operation mode indicator

Transmit indicator Low battery indicator

Set temperature/ Time (for

Fan speed indicator

Timer option) indicator

 

good'sleep indicator

Vertical air swing indicator/

 

 

Horizontal air swing indicator

Options indicator

 

 

Settings indicator

• Make sure that the water does not get to the remote controller.

• The following function are displayed on the remote controller display but not supported in this model. - Horizontal air swing / Virus Doctor / d'light Cool / Usage / Filter Reset / Display

Low Battery warning

When the battery is exhausted, () will be displayed in the remote controller display. When the icon appears, change the batteries. The remote controller requires two 1.5 V AAA type batteries.

Storing the remote controller

When you do not use the remote controller for long time, remove the batteries from the remote controller and store it.

Inserting the batteries

1.Push the lever as arrow indicates on the rear side of the remote controller and pull up.

2.Insert two AAA batteries.

Check and match the“+”and“-”signs accordingly. Make sure you have inserted the batteries in correct position.

3.Close the cover by place it back to its original position.

You should hear click sound when the cover is locked properly.

• The signal may not be received properly if electronic flourescent lamps such as inverter flourescent lamps are operating in the same space.

• If other electrical products operate by the remote controller, call your nearest contact center.

Correct disposal of batteries in this product

(Applicable in countries with separate collection systems)

This marking on the battery, manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life. Where marked, the chemical symbols Hg, Cd or Pb indicate that the battery contains mercury, cadmium or lead above the reference levels in EC Directive 2006/66. If batteries are not properly disposed of, these substances can cause harm to human health or the environment.

To protect natural resources and to promote material reuse, please separate batteries from other types of waste and recycle them through your local, free battery return system.

English-14

A3050 MG Model IB&IM_DB68-04542A_HP_EN.indd 14

2014/4/2 9:42:49

Image 14
Contents Air Conditioner Contents Features of your new air conditioner Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9English-10 Checking before useOperation ranges Technical Specifications English-11Main parts Operation indicatorChecking the name of the parts DisplayEnglish-13 Checking the remote controllerRemote controller buttons Storing the remote controller Remote controller displayLow Battery warning Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed Horizontal air flow Adjusting the air flow directionVertical air flow English-17When the air conditioner is off Setting the On/Off timerSetting the On timer English-18English-19 Setting the Off timerWhen the air conditioner is on Press the SET buttonAdditional options available ModeEnglish-20 English-21 When the air conditioner is operating in Cool modeStep cooling function 04 OptioWhen the air conditioner is operating in Cool/Heat mode Using the Fast functionUsing the Comfort function English-22English-23 Using the Single user functionSingle user function is only available in Cool/Heat mode Blink and press the SET buttonEnglish-24 Using the Quiet functionQuiet function is only available in Cool/Heat mode 16C ~ 30 CWhen the air conditioner is operating Using the Auto clean functionSetting the Beep sound English-25Such as thinner, kerosene and acetone etc. to clean Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerEnglish-27 Cleaning the air filterRemoving the Air filter Remove the Air filter from the main bodyTop of the Air filter into the the main body.  Reassembling the Air filterEnglish-28 S06r Othe Maintaining the air conditionerEnglish-29 English-30 TroubleshootingAir conditioner You cannot adjust the fan speed Mode. In cool mode Adjustment is notMode is operating in Heat mode, you can adjust the air Press the Power button or disconnect the power plugEnglish-32 Installing the unitGeneral information  a place where the air filter can be replaced easily Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit English-34Top view Side view When installing more than 1 outdoor unitEnglish-35 Accessories in the outdoor unit case AccessoriesAccessories in the indoor unit case English-36Tools for test operations Optional accessoriesTools required for installation General Tools English-37Right a Left B Undersideright C Rearright or left D Fixing the installation plateEnglish-38 ModelRemoving the screws This QR code for detail video of indoor unit installationAssembling the hanger screw English-39Removing the Cover panel Before mounting the indoor unit Assembling the Cover panel After mounting the indoor unitEnglish-40 Connecting the cable Connecting the assembly cableCable specification English-41Each wire is labeled with the corresponding terminal number English-42Cut off the remaining foam insulation English-43Smooth the cut edges TorqueEnglish-44 Evacuating the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeDepth a English-45Put a flare nut slightly into the pipe and modify the flare Drain hose installation English-4640~45 mm Change the direction only when it is necessaryEnglish-47 Drain hose ExtensionConnect a drain hose to the drain plug Evacuating the connected pipesEnglish-48 Ensure that condensation draining is adequateOuter Torque Adding RefrigerantEnglish-49 If you use a pipe longer than 5 mPlease fill in with indelible ink English-50Cylinder with siphon  the factory refrigerant charge of the productPerforming the gas leak tests English-51English-52 Outdoor unit installed on the wall by rackFixing the outdoor unit in place Properly ModelSmart Install mode English-53English-54  Off / Blinking / OnFinal check and trial operation English-55Packing and unpacking guide English-56Apply heat to the contraction tube to contract it How to connect your extended power cablesEnglish-57 After tube contraction work is completed, wrap it withQuestions or COMMENTS? 021-8255