Samsung AR18HVFSEWKNMG, AR24HVFSEWKNMG manual General information, Installing the unit, English-32

Page 32

Safety precautions

Carefully follow the precautions listed below because they are essential to guarantee the safety of the equipment.

Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components.

Verify that installation and testing operations are performed by qualified personnel.

Verify that the air conditioner is not installed in an easily accessible area.

General information

Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation.

For maximum safety, installers should always carefully read the following warnings.

Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred.

This manual explains how to install an indoor unit with a split system with two SAMSUNG units.

The use of other types of units with different control systems may damage the units and invalidate the warranty.

The manufacturer shall not be responsible for damages arising from the use of non compliant units.

This product has been determined to be in compliance with the Low Voltage Directive (2006/95/EC), and the Electromagnetic Compatibility Directive (2004/108/EC) of the European Union.

The manufacturer shall not be responsible for damage originating from unauthorized changes or the improper connection of electric and requirements set forth in the“Operating limits”table, included in the manual, shall immediately invalidate the warranty.

The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry.

Do not use the units if damaged. If problems occur, switch the unit off and disconnect it from the power supply.

In order to help prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy.

Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations should be performed by qualified personnel only.

The unit contains moving parts, which should always be kept out of the reach of children.

Do not attempt to repair, move, alter or reinstall the unit. If performed by unauthorized personnel, these operations may cause electric shocks or fires.

Do not place containers with liquids or other objects on the unit.

All the materials used for the manufacture and packaging of the air conditioner are recyclable.

The packing material and exhaust batteries of the remote controller(optional) must be disposed of in accordance with current laws.

The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely.

Installing the unit

IMPORTANT: When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes.

Upon receipt, inspect the product to verify that it has not been damaged during transport.

If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer.)

English-32

A3050 MG Model IB&IM_DB68-04542A_HP_EN.indd 32

2014/4/2 9:49:42

Image 32
Contents Air Conditioner Contents Features of your new air conditioner Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9English-10 Checking before useOperation ranges Technical Specifications English-11Operation indicator Checking the name of the partsMain parts DisplayEnglish-13 Checking the remote controllerRemote controller buttons Remote controller display Low Battery warningStoring the remote controller Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed Adjusting the air flow direction Vertical air flowHorizontal air flow English-17Setting the On/Off timer Setting the On timerWhen the air conditioner is off English-18Setting the Off timer When the air conditioner is onEnglish-19 Press the SET buttonAdditional options available ModeEnglish-20 When the air conditioner is operating in Cool mode Step cooling functionEnglish-21 04 OptioUsing the Fast function Using the Comfort functionWhen the air conditioner is operating in Cool/Heat mode English-22Using the Single user function Single user function is only available in Cool/Heat modeEnglish-23 Blink and press the SET buttonUsing the Quiet function Quiet function is only available in Cool/Heat modeEnglish-24 16C ~ 30 CUsing the Auto clean function Setting the Beep soundWhen the air conditioner is operating English-25Cleaning the air conditioner Cleaning the indoor unitSuch as thinner, kerosene and acetone etc. to clean Cleaning the outdoor unit heat exchangerCleaning the air filter Removing the Air filterEnglish-27 Remove the Air filter from the main bodyTop of the Air filter into the the main body.  Reassembling the Air filterEnglish-28 S06r Othe Maintaining the air conditionerEnglish-29 English-30 TroubleshootingAir conditioner Mode. In cool mode Adjustment is not Mode is operating in Heat mode, you can adjust the airYou cannot adjust the fan speed Press the Power button or disconnect the power plugEnglish-32 Installing the unitGeneral information Choosing the installation location Power supply line, fuse or circuit breaker a place where the air filter can be replaced easily Indoor unitOutdoor Unit English-34Top view Side view When installing more than 1 outdoor unitEnglish-35 Accessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-36Optional accessories Tools required for installation General ToolsTools for test operations English-37Fixing the installation plate English-38Right a Left B Undersideright C Rearright or left D ModelThis QR code for detail video of indoor unit installation Assembling the hanger screwRemoving the screws English-39Removing the Cover panel Before mounting the indoor unit Assembling the Cover panel After mounting the indoor unitEnglish-40 Connecting the assembly cable Cable specificationConnecting the cable English-41Each wire is labeled with the corresponding terminal number English-42English-43 Smooth the cut edgesCut off the remaining foam insulation TorqueEvacuating the indoor unit Cutting or extending the pipeEnglish-44 Unscrew the caps at the end of each pipeDepth a English-45Put a flare nut slightly into the pipe and modify the flare Drain hose installation English-46Change the direction only when it is necessary English-4740~45 mm Drain hose ExtensionEvacuating the connected pipes English-48Connect a drain hose to the drain plug Ensure that condensation draining is adequateAdding Refrigerant English-49Outer Torque If you use a pipe longer than 5 mEnglish-50 Cylinder with siphonPlease fill in with indelible ink  the factory refrigerant charge of the productPerforming the gas leak tests English-51Outdoor unit installed on the wall by rack Fixing the outdoor unit in placeEnglish-52 Properly ModelSmart Install mode English-53English-54  Off / Blinking / OnFinal check and trial operation English-55Packing and unpacking guide English-56How to connect your extended power cables English-57Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withQuestions or COMMENTS? 021-8255