Samsung AR18HSFSEWKNMG, AR24HVFSEWKNMG, AR18HVFSEWKNMG Final check and trial operation, English-55

Page 55

Final check and trial operation

To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly.

Check the followings:

Strength of the installation site

Tightness of pipe connection to detect gas leak

Electric wiring connection

Heat-resistant insulation of the pipe

Drainage

Grounding conductor connection

Correct operation (follow the steps below)

1. Press the Power button and check the following:

The indicator on the indoor unit lights up.

The airflow blade opens and the fan gears up for operation.

2. Press the Mode button to select Cool or Heat mode.

In Cool mode, use Temp + or button and set the temperature at 16 °C. In Heat mode, use Temp + or button and set the temperature at 30 °C.

• Approximately 3~5 minutes later, outdoor unit will start to operate and the

Cool or Warm air will blow out.

• After 12 minutes of stationary condition check the indoor unit air treatment.

Cooling mode (indoor unit check) Inlet air temp. - Outlet air temp: From 10 °C to 12 °C (indicative delta T)

Heating mode (indoor unit check) Outlet air temp. - Inlet air temp: From 11 °C to 14 °C (indicative delta T)

In heating mode, the indoor fan motor can remain off to avoid cold air blown into conditioned space.

3.Press the Air swing button and check the following:

The airflow blades work properly.

4.Press the Power button to stop the operation.

• When you complete the installation successfully, hand over this manual to the user for storage in a handy and safe

place.

Pump down procedure (when removing the product)

1. Press the Power button on the indoor unit for 5 seconds. Beep will sound immediately to let you know that the product is ready for pump down procedure. Please let the compressor run for more than 5 minutes.

2 . Release the valve caps on High and Low pressure side.

3 . Use L wrench to close the valve on the high pressure side.

4 . After approximately 2 minutes, close the valve on the low pressure side.

5 . Stop operation of the air conditioner by pressing the Power button on the indoor unit or remote controller.

6 . Disconnect the pipes.

English-55

07 INSTALLATION

A3050 MG Model IB&IM_DB68-04542A_HP_EN.indd 55

2014/5/24 9:05:34

Image 55
Contents Air Conditioner Contents Features of your new air conditioner English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningOperation ranges Checking before useEnglish-10 English-11 Technical SpecificationsDisplay Operation indicatorChecking the name of the parts Main partsRemote controller buttons Checking the remote controllerEnglish-13 Inserting the batteries Remote controller displayLow Battery warning Storing the remote controllerBasic function Press the button to set the desired fan speed Press the button to adjust the temperatureEnglish-16 English-17 Adjusting the air flow directionVertical air flow Horizontal air flowEnglish-18 Setting the On/Off timerSetting the On timer When the air conditioner is offPress the SET button Setting the Off timerWhen the air conditioner is on English-19English-20 ModeAdditional options available 04 Optio When the air conditioner is operating in Cool modeStep cooling function English-21English-22 Using the Fast functionUsing the Comfort function When the air conditioner is operating in Cool/Heat modeBlink and press the SET button Using the Single user functionSingle user function is only available in Cool/Heat mode English-2316C ~ 30 C Using the Quiet functionQuiet function is only available in Cool/Heat mode English-24English-25 Using the Auto clean functionSetting the Beep sound When the air conditioner is operatingCleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit Such as thinner, kerosene and acetone etc. to cleanRemove the Air filter from the main body Cleaning the air filterRemoving the Air filter English-27English-28 Reassembling the Air filterTop of the Air filter into the the main body.  English-29 Maintaining the air conditionerS06r Othe Air conditioner TroubleshootingEnglish-30 Press the Power button or disconnect the power plug Mode. In cool mode Adjustment is notMode is operating in Heat mode, you can adjust the air You cannot adjust the fan speedGeneral information Installing the unitEnglish-32 Indoor unit Choosing the installation locationPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyEnglish-34 Outdoor UnitEnglish-35 When installing more than 1 outdoor unitTop view Side view English-36 AccessoriesAccessories in the indoor unit case Accessories in the outdoor unit caseEnglish-37 Optional accessoriesTools required for installation General Tools Tools for test operationsModel Fixing the installation plateEnglish-38 Right a Left B Undersideright C Rearright or left DEnglish-39 This QR code for detail video of indoor unit installationAssembling the hanger screw Removing the screwsEnglish-40 Assembling the Cover panel After mounting the indoor unitRemoving the Cover panel Before mounting the indoor unit English-41 Connecting the assembly cableCable specification Connecting the cableEnglish-42 Each wire is labeled with the corresponding terminal numberTorque English-43Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Evacuating the indoor unitCutting or extending the pipe English-44Put a flare nut slightly into the pipe and modify the flare English-45Depth a English-46 Drain hose installationDrain hose Extension Change the direction only when it is necessaryEnglish-47 40~45 mmEnsure that condensation draining is adequate Evacuating the connected pipesEnglish-48 Connect a drain hose to the drain plugIf you use a pipe longer than 5 m Adding RefrigerantEnglish-49 Outer Torque the factory refrigerant charge of the product English-50Cylinder with siphon Please fill in with indelible inkEnglish-51 Performing the gas leak testsProperly Model Outdoor unit installed on the wall by rackFixing the outdoor unit in place English-52English-53 Smart Install mode Off / Blinking / On English-54English-55 Final check and trial operationEnglish-56 Packing and unpacking guideAfter tube contraction work is completed, wrap it with How to connect your extended power cablesEnglish-57 Apply heat to the contraction tube to contract it021-8255 Questions or COMMENTS?