Samsung AR18HVFSEWKNMG manual Cleaning the air conditioner, Cleaning the indoor unit, English-26

Page 26

Cleaning the air conditioner

Make sure to turn off the power of the indoor unit and cut-off

CAUTION the power supply before cleaning the air conditioner.

Cleaning the indoor unit

fFWipe the surface of the unit with a slightly damp micro fiber cloth when needed.

• Contact the service center when you clean the indoor unit

heat exchanger because it needs to be disassembled.

• Since the panel of the indoor unit is easily scratched, you should use a micro fiber cloth to clean the panel.

When you use the micro fiber cloth, slightly dampen the cloth and remove any debris on the cloth to avoid scratches.

• Do not clean the display using alkaline detergent.

 

 

• Do not use sulfuric acid, hydrochloric acid, organic solvents

CAUTION

 

 

(such as thinner, kerosene and acetone etc.) to clean the

 

 

 

 

surface of the product or put any stickers on it.

 

 

They may damage the surface of the air conditioner.

Cleaning the outdoor unit heat exchanger

fFWhen dust accumulates on the heat exchanger, it may decrease cooling performance. Therefore, clean it regularly.

fFSpray water to clean the dust.

• If it is difficult to clean the outdoor unit heat exchanger on your own, contact service center.

• Be careful with the sharp edges on the CAUTION outdoor unit heat exchanger.

Heat exchanger

(Illustration may differ slightly depending on the models)

English-26

A3050 MG Model IB&IM_DB68-04542A_HP_EN.indd 26

2014/4/2 9:15:18

Image 26
Contents Air Conditioner Contents Features of your new air conditioner Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9English-10 Checking before useOperation ranges Technical Specifications English-11Main parts Operation indicatorChecking the name of the parts DisplayEnglish-13 Checking the remote controllerRemote controller buttons Storing the remote controller Remote controller displayLow Battery warning Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed Horizontal air flow Adjusting the air flow directionVertical air flow English-17When the air conditioner is off Setting the On/Off timerSetting the On timer English-18English-19 Setting the Off timerWhen the air conditioner is on Press the SET buttonAdditional options available ModeEnglish-20 English-21 When the air conditioner is operating in Cool modeStep cooling function 04 OptioWhen the air conditioner is operating in Cool/Heat mode Using the Fast functionUsing the Comfort function English-22 English-23 Using the Single user function Single user function is only available in Cool/Heat mode Blink and press the SET buttonEnglish-24 Using the Quiet functionQuiet function is only available in Cool/Heat mode 16C ~ 30 CWhen the air conditioner is operating Using the Auto clean functionSetting the Beep sound English-25Such as thinner, kerosene and acetone etc. to clean Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerEnglish-27 Cleaning the air filterRemoving the Air filter Remove the Air filter from the main bodyTop of the Air filter into the the main body.  Reassembling the Air filterEnglish-28 S06r Othe Maintaining the air conditionerEnglish-29 English-30 TroubleshootingAir conditioner You cannot adjust the fan speed Mode. In cool mode Adjustment is notMode is operating in Heat mode, you can adjust the air Press the Power button or disconnect the power plugEnglish-32 Installing the unitGeneral information  a place where the air filter can be replaced easily Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit English-34Top view Side view When installing more than 1 outdoor unitEnglish-35 Accessories in the outdoor unit case AccessoriesAccessories in the indoor unit case English-36Tools for test operations Optional accessoriesTools required for installation General Tools English-37Right a Left B Undersideright C Rearright or left D Fixing the installation plateEnglish-38 ModelRemoving the screws This QR code for detail video of indoor unit installationAssembling the hanger screw English-39Removing the Cover panel Before mounting the indoor unit Assembling the Cover panel After mounting the indoor unitEnglish-40 Connecting the cable Connecting the assembly cableCable specification English-41Each wire is labeled with the corresponding terminal number English-42Cut off the remaining foam insulation English-43Smooth the cut edges TorqueEnglish-44 Evacuating the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeDepth a English-45Put a flare nut slightly into the pipe and modify the flare Drain hose installation English-4640~45 mm Change the direction only when it is necessaryEnglish-47 Drain hose ExtensionConnect a drain hose to the drain plug Evacuating the connected pipesEnglish-48 Ensure that condensation draining is adequateOuter Torque Adding RefrigerantEnglish-49 If you use a pipe longer than 5 mPlease fill in with indelible ink English-50Cylinder with siphon  the factory refrigerant charge of the productPerforming the gas leak tests English-51English-52 Outdoor unit installed on the wall by rackFixing the outdoor unit in place Properly ModelSmart Install mode English-53English-54  Off / Blinking / OnFinal check and trial operation English-55Packing and unpacking guide English-56Apply heat to the contraction tube to contract it How to connect your extended power cablesEnglish-57 After tube contraction work is completed, wrap it withQuestions or COMMENTS? 021-8255