Samsung AR24HVFSEWKNMG, AR18HSFSEWKNMG, AR18HVFSEWKNMG manual For Using, English-6

Page 6

Safety precautions

FOR POWER SUPPLY

CAUTION

When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker.

Failing to do so may result in electric shock or fire.

FOR USING

 

WARNING

 

If the appliance is flooded, please contact your nearest service center.

Failing to do so may result in electric shock or fire.

If the appliance generates a strange noise, a burning smell or smoke, cut- off the power supply immediately and contact the nearest service center.

Failing to do so may result in electric shock or fire.

In the event of a gas leak (such as propane gas, LP gas, etc.), ventilate immediately without touching the power line. Do not touch the appliance or power line.

Do not use a ventilating fan.

A spark may result in an explosion or fire.

To reinstall the air conditioner, please contact your nearest service center.

Failing to do so may result in problems with the product, water leakage, electric shock, or fire.

A delivery service for the product is not provided. If you reinstall the product in another location, additional construction expenses and an installation fee will be charged.

Especially, when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to the salt in the air, please contact your nearest service center.

Do not touch the circuit breaker with wet hands.

This may result in electric shock.

Do not turn the air conditioner off with the circuit breaker while it is operating.

Turning the air conditioner off and then on again with the circuit breaker may cause a spark and result in electric shock or fire.

After unpacking the air conditioner, keep all packaging materials well out of the reach of children, as packaging materials can be dangerous to children.

If a child places a bag over its head, it may result in suffocation.

English-6

A3050 MG Model IB&IM_DB68-04542A_HP_EN.indd 6

2014/4/1 11:48:51

Image 6
Contents Air Conditioner Contents Features of your new air conditioner Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Checking before use Operation rangesEnglish-10 Technical Specifications English-11Main parts Operation indicatorChecking the name of the parts DisplayChecking the remote controller Remote controller buttonsEnglish-13 Storing the remote controller Remote controller displayLow Battery warning Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Horizontal air flow Adjusting the air flow directionVertical air flow English-17When the air conditioner is off Setting the On/Off timerSetting the On timer English-18English-19 Setting the Off timerWhen the air conditioner is on Press the SET buttonMode English-20Additional options available English-21 When the air conditioner is operating in Cool modeStep cooling function 04 OptioWhen the air conditioner is operating in Cool/Heat mode Using the Fast functionUsing the Comfort function English-22English-23 Using the Single user functionSingle user function is only available in Cool/Heat mode Blink and press the SET buttonEnglish-24 Using the Quiet functionQuiet function is only available in Cool/Heat mode 16C ~ 30 CWhen the air conditioner is operating Using the Auto clean functionSetting the Beep sound English-25Such as thinner, kerosene and acetone etc. to clean Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerEnglish-27 Cleaning the air filterRemoving the Air filter Remove the Air filter from the main bodyReassembling the Air filter English-28Top of the Air filter into the the main body.  Maintaining the air conditioner English-29S06r Othe Troubleshooting Air conditionerEnglish-30 You cannot adjust the fan speed Mode. In cool mode Adjustment is notMode is operating in Heat mode, you can adjust the air Press the Power button or disconnect the power plugInstalling the unit General informationEnglish-32  a place where the air filter can be replaced easily Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit English-34When installing more than 1 outdoor unit English-35Top view Side view Accessories in the outdoor unit case AccessoriesAccessories in the indoor unit case English-36Tools for test operations Optional accessoriesTools required for installation General Tools English-37Right a Left B Undersideright C Rearright or left D Fixing the installation plateEnglish-38 ModelRemoving the screws This QR code for detail video of indoor unit installationAssembling the hanger screw English-39Assembling the Cover panel After mounting the indoor unit English-40Removing the Cover panel Before mounting the indoor unit Connecting the cable Connecting the assembly cableCable specification English-41Each wire is labeled with the corresponding terminal number English-42Cut off the remaining foam insulation English-43Smooth the cut edges TorqueEnglish-44 Evacuating the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeEnglish-45 Put a flare nut slightly into the pipe and modify the flareDepth a Drain hose installation English-4640~45 mm Change the direction only when it is necessaryEnglish-47 Drain hose ExtensionConnect a drain hose to the drain plug Evacuating the connected pipesEnglish-48 Ensure that condensation draining is adequateOuter Torque Adding RefrigerantEnglish-49 If you use a pipe longer than 5 mPlease fill in with indelible ink English-50Cylinder with siphon  the factory refrigerant charge of the productPerforming the gas leak tests English-51English-52 Outdoor unit installed on the wall by rackFixing the outdoor unit in place Properly ModelSmart Install mode English-53English-54  Off / Blinking / OnFinal check and trial operation English-55Packing and unpacking guide English-56Apply heat to the contraction tube to contract it How to connect your extended power cablesEnglish-57 After tube contraction work is completed, wrap it withQuestions or COMMENTS? 021-8255