Choosing the installation location

Outdoor Unit

Where it is not exposed to strong wind

Well ventilated and dustless places

Where possible keep out of sunlight and rain

Where neighbors are not annoyed by operation sound or hot air

Solid wall or support that prevents vibration and is strong enough to hold the product weight

Where there is no risk of flammable gas leakage

When installing the unit at a high place be sure to fix the unit legs

3 m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)

Install the unit horizontally

Place where drained water does not become any problem.

Place with no plants (especially climbing plants) and where small animal can not access.

Outdoor unit should not be place higher than 2.4 m or directly under eaves for accessibility for service and OH&S reasons.

• Avoid the following places to prevent malfunction of the unit

 

 

 

 

- Where there is machine oil

 

- Salty environment such as seaside areas

 

 

- Where sulfide gas exists

 

- Other special atmosphere areas

 

 

 

 

 

100 mm or more

 

 

 

 

 

125 mm

125 mm or

 

 

 

 

or more

 

 

 

 

more

 

 

 

 

 

 

 

 

 

Wrap the refrigerant pipes and the drain hose

You can select the direction of

 

 

 

 

with the absorbent pad and vinyl tape. Refer to

 

 

 

 

draining (left or right).

 

 

 

 

page 52 for further details.

 

 

 

 

 

 

 

 

 

 

 

 

 

'L' m as maximum pipe length

 

 

 

 

 

 

and 3 m as minimum pipe length.

 

 

 

 

 

 

(It will reduce noise and vibration)

 

 

 

 

 

 

 

'H' meters maximum

 

 

 

 

'L' meters maximum

total pipe height

 

 

 

 

 

 

 

 

 

 

total pipe length

 

 

 

 

 

 

 

Model

Pipe Length

Pipe Height

 

 

 

Minimum

Maximum

Maximum

 

 

 

 

 

 

 

09/12

3

15

8

 

 

 

18/24

3

30

15

Make at least one round: It will help reduce noise and vibration.

The appearance of the unit may be different from the diagram depending on the model.

English-34

A3050 MG Model IB&IM_DB68-04542A_HP_EN.indd 34

2014/6/9 11:48:02

Image 34
Contents Air Conditioner Contents Features of your new air conditioner Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Operation ranges Checking before useEnglish-10 Technical Specifications English-11Main parts Operation indicatorChecking the name of the parts DisplayRemote controller buttons Checking the remote controllerEnglish-13 Storing the remote controller Remote controller displayLow Battery warning Inserting the batteriesBasic function Press the button to set the desired fan speed Press the button to adjust the temperatureEnglish-16 Horizontal air flow Adjusting the air flow directionVertical air flow English-17When the air conditioner is off Setting the On/Off timerSetting the On timer English-18English-19 Setting the Off timerWhen the air conditioner is on Press the SET buttonEnglish-20 ModeAdditional options available English-21 When the air conditioner is operating in Cool modeStep cooling function 04 OptioWhen the air conditioner is operating in Cool/Heat mode Using the Fast functionUsing the Comfort function English-22English-23 Using the Single user functionSingle user function is only available in Cool/Heat mode Blink and press the SET buttonEnglish-24 Using the Quiet functionQuiet function is only available in Cool/Heat mode 16C ~ 30 CWhen the air conditioner is operating Using the Auto clean functionSetting the Beep sound English-25Such as thinner, kerosene and acetone etc. to clean Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerEnglish-27 Cleaning the air filterRemoving the Air filter Remove the Air filter from the main bodyEnglish-28 Reassembling the Air filterTop of the Air filter into the the main body.  English-29 Maintaining the air conditionerS06r Othe Air conditioner TroubleshootingEnglish-30 You cannot adjust the fan speed Mode. In cool mode Adjustment is not Mode is operating in Heat mode, you can adjust the air Press the Power button or disconnect the power plugGeneral information Installing the unitEnglish-32  a place where the air filter can be replaced easily Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit English-34English-35 When installing more than 1 outdoor unitTop view Side view Accessories in the outdoor unit case AccessoriesAccessories in the indoor unit case English-36Tools for test operations Optional accessoriesTools required for installation General Tools English-37Right a Left B Undersideright C Rearright or left D Fixing the installation plateEnglish-38 ModelRemoving the screws This QR code for detail video of indoor unit installationAssembling the hanger screw English-39English-40 Assembling the Cover panel After mounting the indoor unitRemoving the Cover panel Before mounting the indoor unit Connecting the cable Connecting the assembly cableCable specification English-41Each wire is labeled with the corresponding terminal number English-42Cut off the remaining foam insulation English-43Smooth the cut edges TorqueEnglish-44 Evacuating the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipePut a flare nut slightly into the pipe and modify the flare English-45Depth a Drain hose installation English-4640~45 mm Change the direction only when it is necessaryEnglish-47 Drain hose ExtensionConnect a drain hose to the drain plug Evacuating the connected pipesEnglish-48 Ensure that condensation draining is adequateOuter Torque Adding RefrigerantEnglish-49 If you use a pipe longer than 5 mPlease fill in with indelible ink English-50Cylinder with siphon  the factory refrigerant charge of the productPerforming the gas leak tests English-51English-52 Outdoor unit installed on the wall by rackFixing the outdoor unit in place Properly ModelSmart Install mode English-53English-54  Off / Blinking / OnFinal check and trial operation English-55Packing and unpacking guide English-56Apply heat to the contraction tube to contract it How to connect your extended power cablesEnglish-57 After tube contraction work is completed, wrap it withQuestions or COMMENTS? 021-8255