Evacuating the indoor unit

The indoor unit is supplied with inert gas (nitrogen).

Before installing the unit, check if nitrogen gas flow out of indoor unit.

If this one isn’t true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit.

1.Unscrew the caps at the end of each pipe.

All inert gas exhausts from the indoor unit.

• To prevent dirt or foreign substances from getting into the pipes

 

 

during installation, do NOT remove the caps completely until you are

 

 

ready to connect the pipes.

 

 

• The remaining air in the Refrigeration cycle, which contains moisture,

 

 

may cause malfunction on the compressor.

 

 

• Always contact the service center or a professional installation agency

Pipes

Unscrew the

for product installation.

 

caps

 

 

Cutting or extending the pipe

The length of the pipe can be:

Extended up to : see table page 34

Shorten up to: see page 34

If you need a pipe longer than 5 meters:

• You must add refrigerant to the pipes; otherwise, the indoor unit may freeze.

1.Make sure that you have all the required tools (pipe cutter, reamer, flaring tool and pipe holder).

2.If you want to shorten the pipe, cut it using a pipe cutter, ensuring that the cut edge remains at 90° with the side of the pipe (see below examples of correct and incorrect cut edges).

Pipe cutter

Pipe

Oblique Rough Burr

3. To prevent a gas leak, remove all burrs at the cut edge of the pipe using a reamer.

• Face the pipe down while removing the burrs to make sure that burrs do not get in to the pipe.

English-44

A3050 MG Model IB&IM_DB68-04542A_HP_EN.indd 44

2014/4/2 9:49:55

Image 44
Contents Air Conditioner Contents Features of your new air conditioner Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9English-10 Checking before useOperation ranges Technical Specifications English-11Operation indicator Checking the name of the partsMain parts DisplayEnglish-13 Checking the remote controllerRemote controller buttons Remote controller display Low Battery warningStoring the remote controller Inserting the batteriesBasic function English-16 Press the button to adjust the temperaturePress the button to set the desired fan speed Adjusting the air flow direction Vertical air flowHorizontal air flow English-17Setting the On/Off timer Setting the On timerWhen the air conditioner is off English-18Setting the Off timer When the air conditioner is onEnglish-19 Press the SET buttonAdditional options available ModeEnglish-20 When the air conditioner is operating in Cool mode Step cooling functionEnglish-21 04 OptioUsing the Fast function Using the Comfort functionWhen the air conditioner is operating in Cool/Heat mode English-22Using the Single user function Single user function is only available in Cool/Heat modeEnglish-23 Blink and press the SET buttonUsing the Quiet function Quiet function is only available in Cool/Heat modeEnglish-24 16C ~ 30 CUsing the Auto clean function Setting the Beep soundWhen the air conditioner is operating English-25Cleaning the air conditioner Cleaning the indoor unitSuch as thinner, kerosene and acetone etc. to clean Cleaning the outdoor unit heat exchangerCleaning the air filter Removing the Air filterEnglish-27 Remove the Air filter from the main bodyTop of the Air filter into the the main body.  Reassembling the Air filterEnglish-28 S06r Othe Maintaining the air conditionerEnglish-29 English-30 TroubleshootingAir conditioner Mode. In cool mode Adjustment is not Mode is operating in Heat mode, you can adjust the airYou cannot adjust the fan speed Press the Power button or disconnect the power plugEnglish-32 Installing the unitGeneral information Choosing the installation location Power supply line, fuse or circuit breaker a place where the air filter can be replaced easily Indoor unitOutdoor Unit English-34Top view Side view When installing more than 1 outdoor unitEnglish-35 Accessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-36Optional accessories Tools required for installation General ToolsTools for test operations English-37Fixing the installation plate English-38Right a Left B Undersideright C Rearright or left D ModelThis QR code for detail video of indoor unit installation Assembling the hanger screwRemoving the screws English-39Removing the Cover panel Before mounting the indoor unit Assembling the Cover panel After mounting the indoor unitEnglish-40 Connecting the assembly cable Cable specificationConnecting the cable English-41Each wire is labeled with the corresponding terminal number English-42English-43 Smooth the cut edgesCut off the remaining foam insulation TorqueEvacuating the indoor unit Cutting or extending the pipeEnglish-44 Unscrew the caps at the end of each pipeDepth a English-45Put a flare nut slightly into the pipe and modify the flare Drain hose installation English-46Change the direction only when it is necessary English-4740~45 mm Drain hose ExtensionEvacuating the connected pipes English-48Connect a drain hose to the drain plug Ensure that condensation draining is adequateAdding Refrigerant English-49Outer Torque If you use a pipe longer than 5 mEnglish-50 Cylinder with siphonPlease fill in with indelible ink  the factory refrigerant charge of the productPerforming the gas leak tests English-51Outdoor unit installed on the wall by rack Fixing the outdoor unit in placeEnglish-52 Properly ModelSmart Install mode English-53English-54  Off / Blinking / OnFinal check and trial operation English-55Packing and unpacking guide English-56How to connect your extended power cables English-57Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withQuestions or COMMENTS? 021-8255