Samsung AR24HVFSEWKNMG manual Choosing the installation location, Indoor unit, English-33

Page 33

After completing the installation, always carry out a functional test and provide the instructions on how to operate the air conditioner to the user.

Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires, explosions or injuries.

To help prevent injury when accidentally touching the indoor unit fan, install the indoor unit at least 2.5 m above the floor.

The air conditioner should be used only for the applications for which it has been designed : the indoor unit is not suitable to be installed in areas used for laundry.

Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs. The units’components must be accessible and that can be disassembled in conditions of complete safety either for people or things.

For this reason, where it is not observed as indicated into the Installation Manual, the cost necessary to reach and repair the unit (in safety, as required by current regulations in force) with slings, trucks, scaffolding or any other means of elevation won’t be considered in-warranty and charged to end user.

Power supply line, fuse or circuit breaker

Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in compliance with current local safety standards.

Always verify that a suitable grounding connection is available.

Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines.

Always verify that the cut-off and protection switches are suitably dimensioned.

Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual.

Always verify that electric connections (cable entry, section of leads, protections…) are compliant with the electric specifications and with the instructions provided in the wiring scheme.

Always verify that all connections comply with the standards applicable to the installation of air conditioners.

07 INSTALLATION

Choosing the installation location

Indoor unit

For Wi-Fi Air-conditioner installation, select indoor unit location near to wireless router.

In case Wi-Fi signal strength weakened , Smart APP may be disconnected depending on the Wi-Fi signal strength.

Where airflow is not blocked.

Where cool air can be distributed throughout the room.

Install the refrigerant piping length and the height difference of both indoor and outdoor units as indicated in the installation diagram.

Wall that prevents vibration and is strong enough to hold the product weight.

Out of the direct sunlight .

1 m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated).

As far away as possible from the fluorescent and incandescent lights (so that the remote controller can be operated well).

A place where the air filter can be replaced easily.

Don't install directly above electronics equipment as leaking water may cause damage if not serviced. (eg. Computers, TV, etc).

English-33

A3050 MG Model IB&IM_DB68-04542A_HP_EN.indd 33

2014/4/2 9:49:42

Image 33
Contents Air Conditioner Contents Features of your new air conditioner English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningChecking before use Operation rangesEnglish-10 English-11 Technical SpecificationsChecking the name of the parts Operation indicatorMain parts DisplayChecking the remote controller Remote controller buttonsEnglish-13 Low Battery warning Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-16 Vertical air flow Adjusting the air flow directionHorizontal air flow English-17Setting the On timer Setting the On/Off timerWhen the air conditioner is off English-18When the air conditioner is on Setting the Off timerEnglish-19 Press the SET buttonMode English-20Additional options available Step cooling function When the air conditioner is operating in Cool modeEnglish-21 04 OptioUsing the Comfort function Using the Fast functionWhen the air conditioner is operating in Cool/Heat mode English-22Single user function is only available in Cool/Heat mode Using the Single user functionEnglish-23 Blink and press the SET buttonQuiet function is only available in Cool/Heat mode Using the Quiet functionEnglish-24 16C ~ 30 CSetting the Beep sound Using the Auto clean functionWhen the air conditioner is operating English-25Cleaning the indoor unit Cleaning the air conditionerSuch as thinner, kerosene and acetone etc. to clean Cleaning the outdoor unit heat exchangerRemoving the Air filter Cleaning the air filterEnglish-27 Remove the Air filter from the main bodyReassembling the Air filter English-28Top of the Air filter into the the main body.  Maintaining the air conditioner English-29S06r Othe Troubleshooting Air conditioner English-30 Mode is operating in Heat mode, you can adjust the air Mode. In cool mode Adjustment is notYou cannot adjust the fan speed Press the Power button or disconnect the power plugInstalling the unit General informationEnglish-32 Power supply line, fuse or circuit breaker Choosing the installation location a place where the air filter can be replaced easily Indoor unitEnglish-34 Outdoor UnitWhen installing more than 1 outdoor unit English-35Top view Side view Accessories in the indoor unit case AccessoriesAccessories in the outdoor unit case English-36Tools required for installation General Tools Optional accessoriesTools for test operations English-37English-38 Fixing the installation plateRight a Left B Undersideright C Rearright or left D ModelAssembling the hanger screw This QR code for detail video of indoor unit installationRemoving the screws English-39Assembling the Cover panel After mounting the indoor unit English-40Removing the Cover panel Before mounting the indoor unit Cable specification Connecting the assembly cableConnecting the cable English-41English-42 Each wire is labeled with the corresponding terminal numberSmooth the cut edges English-43Cut off the remaining foam insulation TorqueCutting or extending the pipe Evacuating the indoor unitEnglish-44 Unscrew the caps at the end of each pipeEnglish-45 Put a flare nut slightly into the pipe and modify the flareDepth a English-46 Drain hose installationEnglish-47 Change the direction only when it is necessary40~45 mm Drain hose ExtensionEnglish-48 Evacuating the connected pipesConnect a drain hose to the drain plug Ensure that condensation draining is adequateEnglish-49 Adding RefrigerantOuter Torque If you use a pipe longer than 5 mCylinder with siphon English-50Please fill in with indelible ink  the factory refrigerant charge of the productEnglish-51 Performing the gas leak testsFixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-52 Properly ModelEnglish-53 Smart Install mode Off / Blinking / On English-54English-55 Final check and trial operationEnglish-56 Packing and unpacking guideEnglish-57 How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it with021-8255 Questions or COMMENTS?