Heatiator CD4236ILR-C, CD4236IR-C, CD4842ILR-C, CD4842IR-C Fire Risk, Slp-Hrc-Ss Slp-Hrc-Zc-Ss

Page 68

WARNING

Fire Risk.

When using SLP-HRC-SS and SLP-HRC-ZC- SS termination caps on top vented fireplaces, a one foot minimum vertical vent section is

required before installing first elbow.

When using DVP-TB1 termination cap on top vented fireplaces, a three foot minimum vertical vent section is required before installing first elbow.

8-1/8 in.

(206 mm)

15 in.

(381 mm)

 

7-1/4 in.

1 in.

(184 mm)

(25 mm)

13 in.

Effective Length

 

 

(330 mm)

5-1/2 in.

8-3/8 in.

5-3/4 to 8-3/8 in.

 

 

146 to 213 mm

140 mm

213 mm

 

 

87°

 

 

 

10-1/2 in.

267 mm

10-7/8 in. 276 mm

SLP-HRC-SS

SLP-HRC-ZC-SS

HORIZONTAL TERMINATION CAP

14 in.

 

(356 mm)

PVK-80

(For use with IPI and DSI appliances only.)

3/8 in. (10 mm) 1 in. (25 mm)

7-3/4 to 10-3/8 in.

(197 to 264 mm)

C

DVP-FBHT

FireBrickTermination Cap

D

A

B

LDS33/LDS46 Decorative Shroud

 

 

A

 

B

 

C

 

D

Catalog #

in.

mm

in.

mm

in.

mm

in.

mm

LDS33

36

914

36

914

8.5

216

11

279

LDS46

48

1219

72

1829

8.5

216

11

279

Figure 16.9

68

Heatilator • CD4236IR-C, CD4842IR-C2207-900 Rev. J • 11/11

Image 68
Contents Models CD4236IR-C CD4842IR-C CD4236ILR-C CD4842ILR-C What to do if you smell gasHOT Surfaces Hot glass will cause burnsCongratulations Homeowner Reference InformationTable of Contents User GuideAppliance Setup TroubleshootingFinishing Reference MaterialsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsYour Fireplace Gas Fireplace SafetyOperating Instructions User Guide Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesIPI Battery Tray/Battery Installation Fan Kit optionalModule Reset Nine Hour Safety Shutdown FeatureControl Module Operation Before Lighting FireplaceLighting Instructions IPI Final inspection byWhat to do if YOU Smell GAS GAS ValveAfter Fireplace is Lit Frequently Asked QuestionsIssue Solutions Maintenance and Service Maintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionLogs FireboxLogs/Grate and Valve Assembly Removal Extra Screws to be Removed for CD4842IR-CRemove burner skirt by removing 4 screws. See Figure Burner Identification/Verification 12 Burner identification ExamplesGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Any such action may cause a fire hazardFraming and Clearances Selecting Appliance LocationCD4236 Series CD4842 SeriesMinimum Framing Dimensions Constructing the Appliance ChaseClearances Mantel and Wall ProjectionsTermination Locations Vent Termination Minimum ClearancesCovered Alcove Applications Inches U.S.AVent Information and Diagrams Approved PipeVent Table Key Use of ElbowsVent Diagrams Top Vent Horizontal TerminationTop Vent Horizontal Termination One Elbow Two ElbowsV1 Minimum H1 Maximum V1 Minimum H1 + H2 MaximumTop Vent Horizontal Termination Three Elbows Min MaxBreak Here Top Vent Vertical Termination Maximum + V 2 MinTop Vent Vertical Termination Three Elbows H1 + H2 V1 + V2 Minimum H1 + H2 MaximumHeatilator CD4236IR-C, CD4842IR-C 2207-900 Rev. J 11/11 H1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Max Rear Vent Horizontal Termination Two ElbowsH1 Maximum V1 Minimum H1 + H2 Maximum Rear Vent Vertical Termination One Elbow Two Elbows Minimum MaximumRear Vent Vertical Termination Three Elbows V1 Minimum H1 + H2 + H3 Maximum 10 ftVent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVP SLPInstall Attic Insulation Shield Installing the Optional Heat-ZoneGas KitFlat Ceiling Installation Vaulted Ceiling InstallationAppliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outHeader Installing the Non-combustible BoardSecuring and Leveling the Appliance Installing Vent Pipe DVP and SLP Pipe Attach Vent to the Firebox AssemblyAssemble Vent Sections DVP Pipe Only Assemble Pipe SectionsAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components SLP only Install Horizontal Termination Cap DVP and SLP Pipe DVP-HPC1 DVP-HPC2Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements IntelliFire PlusTM Ignition System WiringOptional Accessories Requirements Electrical InformationElectrical Service and Repair Junction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialCombustible Mantels CD4236Appliance Setup LOG Placement Instructions Install the Log AssemblyInstall Trim and/or Surround Air Shutter SettingAir Shutter Settings CD4236IR-C CD4842IR-C Fully OpenIntelliFire PlusTM Ignition System TroubleshootingSymptom Possible Cause Corrective Action Troubleshooting Location Inches Millimeters Appliance Dimension DiagramReference Materials GAS Line Access R Left Side TOP View Front View Right View Vent Components Diagrams DVP-AS2DVP-TRAP Horizontal Termination CapRF6M RF12M BEK DVP-BEK2DVP-TRAPFL COOL-ADDDVP-FBHT Optional Wire Harness PVI-SLPSLP-LPC DVP-HRC-SS DVP-HRC-ZC-SS222 mm 165 mm 165 mm9-1/4 235 mm 152 mm 168 mm Elbow251 mm Effective Height LengthSLP-SNKD SLP-CCS-BK SLP-TVHW Fire Risk SLP-HRC-SS SLP-HRC-ZC-SSService Parts Log Set AssemblyAt Depot 36 in. Caliber DVStocked 42 in. Caliber DV#19 Valve Assembly CD4236IR-CCD4842IR-C Beginning Manufacturing Date Dec Ending Manufacturing DateCD4236IR-C, CD4236ILR-C, CD4842IR-C, CD4842ILR-C Contact Information