Heatiator CD4842ILR-C, CD4236ILR-C, CD4236IR-C, CD4842IR-C owner manual Stocked, 42 in. Caliber DV

Page 70

Service Parts

CD4842IR-C, CD4842ILR-C

42 in. Caliber - DV

Beginning Manufacturing Date: Dec 2009

 

Ending Manufacturing Date: ______

Log Set Assembly

 

7

5

4

 

 

8

6

 

9

1

 

 

3

2

 

10

 

 

 

 

 

 

22

 

 

16 15

14

 

 

11

 

 

17

 

 

 

 

12

 

 

 

 

13

 

 

 

 

21

 

 

18

 

 

 

 

 

 

20

 

 

 

 

19

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for

 

Stocked

your appliance please provide model number and serial number. All parts listed in this manual may

 

be ordered from an authorized dealer.

 

 

at Depot

 

 

 

 

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

 

 

Log Assembly

 

LOGS-4842

Y

1

Log #1

 

SRV2208-702

 

2

Log #2

 

SRV2208-703

 

3

Log #3

 

SRV2208-704

 

4

Log #4

 

SRV2211-073

 

5

Log #5

 

SRV2208-705

 

6

Log #6

 

SRV2208-706

 

7

Insulation Board

 

2170-136

 

8

Refractory Back

 

2210-720

 

9

Refractory Side

Left

2210-721

 

Right

2210-722

 

 

 

 

10

Glass Heat Shield

 

2210-723

 

11

Grate Assembly

 

2211-015

 

12

Burner Assembly NG

 

2210-007

Y

Burner Assembly LP

 

2210-008

Y

 

 

13

Burner Skirt

 

2208-102

 

14

Glass Assembly

 

GLA-950TR

Y

15

Screen Assembly

 

560-382A

Y

16

Hood

 

SRV560-175

 

17

Louver Assembly, Top

 

2210-021

 

18

Louver Assembly, Bottom

 

2210-020

 

19

Valve Assembly

Refer to valve page

 

20

Base Pan

 

2211-100

 

21

Junction Box (Plastic)

 

4021-013

Y

22

Exhaust Cover Shield

 

385-105

 

Additional service part numbers appear on following page.

70

Heatilator • CD4236IR-C, CD4842IR-C2207-900 Rev. J • 11/11

Image 70
Contents HOT Surfaces Models CD4236IR-C CD4842IR-C CD4236ILR-C CD4842ILR-CWhat to do if you smell gas Hot glass will cause burnsCongratulations Homeowner Reference InformationTable of Contents User GuideFinishing Appliance SetupTroubleshooting Reference MaterialsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace IPI Battery Tray/Battery Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalControl Module Operation Module ResetNine Hour Safety Shutdown Feature Before Lighting FireplaceWhat to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveIssue Solutions Frequently Asked QuestionsAfter Fireplace is Lit Maintenance and Service Logs Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection FireboxLogs/Grate and Valve Assembly Removal Extra Screws to be Removed for CD4842IR-CRemove burner skirt by removing 4 screws. See Figure Burner Identification/Verification 12 Burner identification ExamplesGetting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Any such action may cause a fire hazardCD4236 Series Framing and ClearancesSelecting Appliance Location CD4842 SeriesMinimum Framing Dimensions Constructing the Appliance ChaseClearances Mantel and Wall ProjectionsTermination Locations Vent Termination Minimum ClearancesCovered Alcove Applications Inches U.S.AVent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsVent Diagrams Top Vent Horizontal TerminationV1 Minimum H1 Maximum Top Vent Horizontal Termination One ElbowTwo Elbows V1 Minimum H1 + H2 MaximumTop Vent Horizontal Termination Three Elbows Min MaxBreak Here Top Vent Vertical Termination Maximum + V 2 MinTop Vent Vertical Termination Three Elbows H1 + H2 V1 + V2 Minimum H1 + H2 MaximumHeatilator CD4236IR-C, CD4842IR-C 2207-900 Rev. J 11/11 H1 Maximum V1 Minimum H1 + H2 Maximum Rear Vent Horizontal Termination Two ElbowsH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Max Rear Vent Vertical Termination One Elbow Two Elbows Minimum MaximumRear Vent Vertical Termination Three Elbows V1 Minimum H1 + H2 + H3 Maximum 10 ftWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVP SLPFlat Ceiling Installation Install Attic Insulation ShieldInstalling the Optional Heat-ZoneGas Kit Vaulted Ceiling InstallationAppliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outSecuring and Leveling the Appliance Installing the Non-combustible BoardHeader Assemble Vent Sections DVP Pipe Only Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Pipe SectionsAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Install Metal Roof Flashing Assemble and Install Storm CollarInstall Decorative Wall Components SLP only Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe DVP-HPC1 DVP-HPC2Gas Pressure Gas InformationFuel Conversion Gas ConnectionOptional Accessories Requirements Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Electrical InformationElectrical Service and Repair Junction Box Installation Wall Switch Installation for Fan OptionalCombustible Mantels FinishingFacing Material CD4236Appliance Setup LOG Placement Instructions Install the Log AssemblyAir Shutter Settings Install Trim and/or SurroundAir Shutter Setting CD4236IR-C CD4842IR-C Fully OpenSymptom Possible Cause Corrective Action TroubleshootingIntelliFire PlusTM Ignition System Troubleshooting Reference Materials Appliance Dimension DiagramLocation Inches Millimeters GAS Line Access R Left Side TOP View Front View Right View Vent Components Diagrams DVP-AS2DVP-TRAP Horizontal Termination CapDVP-TRAPFL RF6M RF12MBEK DVP-BEK2 COOL-ADDDVP-FBHT SLP-LPC Optional Wire HarnessPVI-SLP DVP-HRC-SS DVP-HRC-ZC-SS251 mm 222 mm 165 mm 165 mm9-1/4 235 mm 152 mm 168 mmElbow Effective Height LengthSLP-SNKD SLP-CCS-BK SLP-TVHW Fire Risk SLP-HRC-SS SLP-HRC-ZC-SSAt Depot Service PartsLog Set Assembly 36 in. Caliber DVStocked 42 in. Caliber DVCD4842IR-C #19 Valve AssemblyCD4236IR-C Beginning Manufacturing Date Dec Ending Manufacturing DateCD4236IR-C, CD4236ILR-C, CD4842IR-C, CD4842ILR-C Contact Information