Carrier 48EZ(N)-A installation instructions Medium1

Page 22

22

 

 

 

 

 

 

 

 

 

 

 

 

 

48EZ-- A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 7 (cont) - Dry Coil Air Delivery* - Horizontal Discharge - Unit 48EZ-A24-60

 

 

 

 

 

 

 

 

UNIT

 

HEATING RISE

 

MOTOR

 

WIRE

 

 

 

 

EXTERNAL STATIC PRESSURE (in. W.C.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RANGE

 

SPEED

 

COLOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

0.2

0.3

 

0.4

0.5

0.6

 

0.7

0.8

0.9

 

 

 

 

 

 

 

 

CFM

1295

1234

1182

 

1126

1075

1016

 

955

898

857

 

 

 

 

 

 

 

 

Heating Rise

34

36

38

 

39

41

44

 

47

49

52

 

 

 

 

 

Low1

 

Blue

(oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Rise

19

20

21

 

22

23

24

 

26

27

29

 

 

 

 

 

 

 

 

(oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1345

1282

1235

 

1194

1140

1095

 

1027

974

921

 

 

 

 

 

 

 

 

Heating Rise

33

35

36

 

37

39

41

 

43

46

48

 

 

 

 

 

Med---Low

 

Pink

(oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Rise

18

19

20

 

21

22

23

 

24

25

27

 

 

 

 

 

 

 

 

(oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1505

1452

1413

 

1358

1323

1282

 

1234

1169

1130

 

 

 

25 --- 55oF

 

 

 

 

Heating Rise

30

31

31

 

33

34

35

 

36

38

39

 

48EZ( ---,N)A42060

 

 

Medium

 

Red

(oF)

 

 

 

 

(14 --- 31oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Rise

16

17

17

 

18

19

19

 

20

21

22

 

 

 

 

 

 

 

 

(oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1545

1492

1449

 

1411

1362

1313

 

1278

1231

1188

 

 

 

 

 

 

 

 

Heating Rise

29

30

31

 

31

33

34

 

35

36

37

 

 

 

 

 

Med---High2

 

Orange

(oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Rise

16

17

17

 

17

18

19

 

19

20

21

 

 

 

 

 

 

 

 

(oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1705

1643

1607

 

1568

1518

1483

 

1448

1404

1360

 

 

 

 

 

 

 

 

Heating Rise

26

27

28

 

28

29

30

 

31

32

33

 

 

 

 

 

High

 

Black

(oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Rise

14

15

15

 

16

16

17

 

17

18

18

 

 

 

 

 

 

 

 

(oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1295

1234

1182

 

1126

1075

1016

 

955

898

857

 

 

 

 

 

 

 

 

Heating Rise

53

55

58

 

60

63

NA

 

NA

NA

NA

 

 

 

 

 

Low

 

Blue

(oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Rise

29

31

32

 

34

35

NA

 

NA

NA

NA

 

 

 

 

 

 

 

 

(oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1345

1282

1235

 

1194

1140

1095

 

1027

974

921

 

 

 

 

 

 

 

 

Heating Rise

51

53

55

 

57

60

62

 

NA

NA

NA

 

 

 

 

 

Med---Low

 

Pink

(oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Rise

28

29

31

 

32

33

35

 

NA

NA

NA

 

 

 

 

 

 

 

 

(oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1505

1452

1413

 

1358

1323

1282

 

1234

1169

1130

 

 

 

35 --- 65oF

 

 

 

 

Heating Rise

45

47

48

 

50

51

53

 

55

58

60

 

48EZ( ---,N)A42090

 

 

Medium1

 

Red

(oF)

 

 

 

 

(19 --- 36oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Rise

25

26

27

 

28

29

29

 

31

32

33

 

 

 

 

 

 

 

 

(oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1545

1492

1449

 

1411

1362

1313

 

1278

1231

1188

 

 

 

 

 

 

 

 

Heating Rise

44

46

47

 

48

50

52

 

53

55

57

 

 

 

 

 

Med---High2

 

Orange

(oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Rise

24

25

26

 

27

28

29

 

30

31

32

 

 

 

 

 

 

 

 

(oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

1705

1643

1607

 

1568

1518

1483

 

1448

1404

1360

 

 

 

 

 

 

 

 

Heating Rise

40

41

42

 

43

45

46

 

47

48

50

 

 

 

 

 

High

 

Black

(oF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Rise

22

23

24

 

24

25

25

 

26

27

28

 

 

 

 

 

 

 

 

(oC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 22
Contents Table of Contents Safety ConsiderationsCheck Equipment Receiving and InstallationIntroduction Provide Unit Support48EZ-A24-36 Unit Dimensions 48EZ-A42-60 Unit Dimensions Roof Curb Dimensions NumberRig and Place Unit Field Fabricate DuctworkProvide Clearances InspectionConnect Condensate Drain Install Flue HoodInstall Gas Piping Rigging/Lifting of Unit See FigFire or Explosion Hazard Sediment TrapInstall Duct Connections Configuring Units for Downflow Vertical DischargePhysical Data Unit 48EZ-A Maximum Gas Flow Capacity Physical Data Unit 48EZ-A Cont’dHeating Inputs High-Voltage Connections Install Electrical ConnectionsSpecial Procedures for 208-V Operation Unit Component Damage HazardControl Voltage Connections Balance Point Setting-Thermidistat or Hybrid ThermostatPRE-START-UP Transformer ProtectionCheck for Refrigerant Leaks Start-up Heating and Make Adjust- mentsSTART-UP Unit Sequence of OperationCheck Gas Input Adjust Gas InputUnit Damage Hazard Start-up Cooling and Make Adjust- ments Gas Heating Fan Speed Set-up Checking and Adjusting Refrigerant ChargeIndoor Airflow and Airflow Adjustments Unit Operation HazardContinuous Fan Operation Two Cooling Fan Speeds Set-up Dehumidification feature usedColor Coding for Indoor Fan Motor Leads Unit Heating Rise Motor Dry Coil Air Delivery* Horizontal Unit 48EZ-A24-60Range Speed Color Dry Coil Air Delivery* Horizontal Discharge Unit 48EZ-A24-60 1354 1290 1226 1158 1102 1046 981 918 843 55oF Heating Rise Medium1 48EZ ---,NA48090 48EZ ---,NA48130 Unit Heating Rise Motor Wire Downflow Cooling Standard CFM Scfm Economizer + Tons Horizontal and Downflow Filter Pressure Drop Table IN. W.CUnit Standard CFM Scfm Size Cooling Standard CFM Scfm48EZ a 208/230-1-60 Ladder Wiring Diagram, Unit 48EZ-A 208/230-3-60 Connection Wiring Diagram, Unit 48EZ-A Cont. 208/230-3-60 Ladder Wiring Diagram, Unit 48EZ-A Cooling Charging Table-Subcooling Air Filter MaintenanceCleaning the Blower Motor and Wheel Indoor Blower and MotorBurner Ignition Limit SwitchInduced Draft combustion air Blower Assembly Main BurnersOutdoor Fan Electrical Controls and WiringRefrigerant Circuit Gas Input Pressure SwitchesLoss of Charge Switch Indoor AirflowCopeland Scroll Compressor Puron Refrigerant High-Pressure SwitchExplosion Hazard Refrigerant System Unit Operation and Safety HazardCompressor Oil START-UP Checklist TroubleshootingPuronr R-410A Quick Reference Guide Troubleshooting Guide Cooling or Heat Pump Heating Mode Symptom Cause RemedyTroubleshooting Guide-LED Error Codes Troubleshooting Guide-HeatingLED OFF Preliminary Information Model no TemperaturesRemove and Store in Job Files III. START-UP Electrical Supply Voltage Compressor Amps