Energy-Saving Features

good’sleep function

Use the good'sleep function to get a good sleep at night and to save energy. You can select this function both in the Cool and Heat modes.

In the Cool or Heat mode

(Select among

 

On, Off, and .)

(Set the

operation time.)

 

Press the (Timer) button to change the current function between On, Off, and (good’sleep).

NOTE

You can adjust the set temperature by 1 °C between 16 °C and 30 °C.

The recommended and optimal set temperatures in the good’sleep function are as follows:

Mode

Recommended set

Optimal set

temperature

temperature

 

 

 

 

Cool

25 °C to 27 °C

26 °C

 

 

 

Heat

21 °C to 23 °C

22 °C

 

 

 

Once you start the good’sleep function, the (good’sleep) indicator appears on the indoor unit display.

You can set the operation time to between 0.5 and

12 hours. Set the operation time to 0.0 to cancel the good’sleep function.

The default operation time for the good’sleep function in the Cool mode is 8 hours. If the operation time is set to over 5 hours, the Wake up function begins 1 hour before the set time. The air conditioner stops automatically when the operation time expires.

When the Timed on, Timed off, and good'sleep functions are overlapped, the air conditioner operates its timer with only the function that you have started most recently.

24English

Image 25
Contents Questions or COMMENTS? Air conditioner Contents Installation For Installation Safety InformationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning Correct disposal of batteries in this product Display Indoor Unit Overview09/12/18 24/30 Two 1.5V AAA type batteries Remote Control OverviewControlling temperature Remote Control OperationOperation modes Controlling air flow direction Controlling fan speedHorizontal air flow manual Cooling Operation Cool modeStep cooling function Dehumidifying Operation Dry modeHeating Operation Heat modeAuto mode Quick Smart FeaturesFan mode Comfort function Fast functionQuiet function Beep sound functionSingle user function Energy-Saving OperationIs off Timed on/Timed off functionTo 27 C Good’sleep functionTo 23 C Running Auto clean Cleaning at a GlanceAuto Heat Heat, FanVacuum cleaner Soft brush Minutes Cleaning the filterMild detergent Troubleshooting Cleaning and Maintenance Cleaning and Maintenance Cleaning and Maintenance Installation of the unit Safety Information on InstallationGeneral information Power supply line, fuse, or circuit breaker Overview of installation location requirements Choosing the installation locationWhen installing 1 outdoor unit 6 cases Unit mm PreparationAccessories Checking and preparing accessories and toolsWhen installing more than 1 outdoor unit 5 cases Unit mm Accessories in the indoor unit packageAccessories in the outdoor unit package Optional accessoriesDrilling a hole through the wall ToolsDrill the hole Be sure to drill only one hole Taping the pipes, cables, and drain hosePower & Communication cable shall not exceed 30m Indoor Unit InstallationPrepare a compressor and the following tools Optional Extending the power cableApply heat to the contraction tube to contract it Install the drain hose Installing and connecting the drain hoseOptional Extending the drain hose Electric shock or a fireOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a wall Fixing the installation plateWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum boardUsing anchor bolts Outdoor Unit InstallationFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Adding refrigerant Performing the gas leak tests Installation InspectionPerforming final check and trial operation Pumping down refrigerantPumping down for removing the product