Installation
Left Right
Rear right or left
Bottom right <Possible directions of the pipe bundle>
CAUTION
•If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.
Pipe bundle hole
<Minimum distances between the hole and the
installation plate>
|
|
|
| (Unit : mm) | |
|
|
|
|
|
|
Model | A | B | C |
| D |
|
|
|
|
|
|
09/12 | 30 | 166 | 38 |
| 30 |
|
|
|
|
|
|
18/24/30 | 38 | 126 | 70 |
| 38 |
|
|
|
|
| |
|
| Pipe bundle hole: Ø 65 mm |
2Drill the hole.
CAUTION
•Be sure to drill only one hole.
•Make sure that the hole slants downwards so that the drain hose slants downwards to drain water well.
| Wall |
Indoor unit | Drain hose |
|
<The hole slants downwards>
Step 1.4 Taping the pipes, cables, and drain hose
1Wrap foam insulation on parts without insulation on the ends of the refrigerant pipes, as shown in the figure. This wrapping minimises condensation problem.
Insulation
Refrigerant pipes
2Wind the refrigerant pipes, power cable, communication cable and drain hose with vinyl tape to make a pipe bundle.
| Refrigerant pipes |
Installation plate | (assembly pipe) |
|
Vinyl tape
Power and communication cables (assembly cable)
Drain hose