Samsung AR09MSFTBWKNTV, AR30MSFTBWKNTV, AR24MSFTBWKNTV Power supply line, fuse, or circuit breaker

Page 33

When installing the outdoor unit at the seaside, make sure that it is not directly exposed to sea breeze. If you cannot find an adequate place free from direct sea breeze, construct a protection wall or a protective fence.

––Install the outdoor unit in a place (such as near buildings etc.) where it can be protected from sea breeze. Failure to do so may cause a damage to the outdoor unit.

 

Sea breeze

 

Sea breeze

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sea

 

 

Outdoor unit

Sea

 

 

Outdoor unit

If you cannot avoid installing the outdoor unit at the seaside, construct a protection wall around to block the sea breeze.

Construct a protection wall with a solid material such as concrete to block the sea breeze. Make sure that the height and the width of the wall are 1.5 times larger than the size of the outdoor unit. Also, secure a space larger than 600 mm between the protection wall and the outdoor unit for exhausted air to ventilate.

 

 

Sea breeze

 

 

 

 

 

Protection wall

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sea

 

 

 

 

Outdoor unit

 

Protection wall

 

 

Install the unit in a place where water can drain smoothly.

If you have any difficulty finding installation location as prescribed above, contact your manufacturer for details.

Be sure to clean the sea water and the dust on the heat exchanger of the outdoor unit and apply a corrosion inhibitor on it. (At least once in a year.)

Installation

Power supply line, fuse, or circuit breaker

Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in compliance with current local safety standards.

Always verify that a suitable grounding connection is available.

Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines.

Always verify that the cut-off and protection switches are suitably dimensioned.

Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual.

Always verify that electric connections (cable entry, section of leads, protections…) are compliant with the electric specifications and with the instructions provided in the wiring scheme. Always verify that all connections comply with the standards applicable to the installation of air conditioners.

Be sure not to perform power cable modification, extension wiring, and multiple wire connection.

––It may cause electric shock or fire due to poor connection, poor insulation, or current limit override.

––When extension wiring is required due to power line damage, refer to "Step 2.2 Optional: Extending the power cable" in the installation manual.

32English

Image 33
Contents Questions or COMMENTS? Air conditioner Contents Installation For Installation Safety InformationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning Correct disposal of batteries in this product Indoor Unit Overview Display09/12/18 24/30 Two 1.5V AAA type batteries Remote Control OverviewRemote Control Operation Controlling temperatureOperation modes Controlling fan speed Controlling air flow directionHorizontal air flow manual Cool mode Cooling OperationStep cooling function Dehumidifying Operation Dry modeHeating Operation Heat modeQuick Smart Features Auto modeFan mode Comfort function Fast functionQuiet function Beep sound functionSingle user function Energy-Saving OperationIs off Timed on/Timed off functionGood’sleep function To 27 CTo 23 C Running Auto clean Cleaning at a GlanceAuto Heat Heat, FanCleaning the filter Vacuum cleaner Soft brush MinutesMild detergent Troubleshooting Cleaning and Maintenance Cleaning and Maintenance Cleaning and Maintenance Safety Information on Installation Installation of the unitGeneral information Power supply line, fuse, or circuit breaker Overview of installation location requirements Choosing the installation locationWhen installing 1 outdoor unit 6 cases Unit mm PreparationAccessories Checking and preparing accessories and toolsWhen installing more than 1 outdoor unit 5 cases Unit mm Accessories in the indoor unit packageAccessories in the outdoor unit package Optional accessoriesDrilling a hole through the wall ToolsDrill the hole Be sure to drill only one hole Taping the pipes, cables, and drain hosePower & Communication cable shall not exceed 30m Indoor Unit InstallationOptional Extending the power cable Prepare a compressor and the following toolsApply heat to the contraction tube to contract it Install the drain hose Installing and connecting the drain hoseOptional Extending the drain hose Electric shock or a fireOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a wall Fixing the installation plateWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum boardUsing anchor bolts Outdoor Unit InstallationFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Adding refrigerant Performing the gas leak tests Installation InspectionPerforming final check and trial operation Pumping down refrigerantPumping down for removing the product