Samsung AR09MSFTBWKNTV manual Fixing the installation plate, When fixing the indoor unit on a wall

Page 43

Installation

NOTE

Excessive torque may cause gas leakage. When extending the pipe with welding or brazing, ensure that nitrogen is used during the welding or brazing process. The joint must be accessible and serviceable.

CAUTION

Tighten the flare nut at the specified torque. If the flare nut is over-tightened, it may break to cause leakage of refrigerant gas.

Step 2.8 Fixing the installation plate

You can install the indoor unit on a wall, window frame, or gypsum board.

WARNING

Make sure that the wall, window frame, or gypsum board can withstand the weight of the indoor unit. If you install the indoor unit in a place where it is not strong enough to withstand the unit's weight, the unit could fall and cause injury.

When fixing the indoor unit on a wall

Fix the installation plate to the wall giving attention to the weight of the indoor unit.

Plastic anchor

20 mm Wall

 

 

 

 

(Unit : mm)

 

 

 

 

 

 

Model

A

B

C

 

D

 

 

 

 

 

 

09/12

30

166

38

 

30

 

 

 

 

 

 

18/24/30

38

126

70

 

38

 

 

 

 

 

 

 

Pipe bundle hole: Ø 65 mm

NOTE

If you mount the plate to a concrete wall using plastic anchors, make sure that gaps between the wall and the plate, created by projected anchor, is less than 20 mm.

When fixing the indoor unit on a window frame

1Determine the positions of the wooden uprights to be attached to the window frame.

2Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.

3Attach the installation plate to the wooden upright using tapping screws.

When fixing the indoor unit on a gypsum board

1Use stud finder to find out locations of the studs.

2Fix the plate hanger on two studs.

CAUTION

If you fix the indoor unit on a gypsum board, use only specified anchor bolts on reference positions. Otherwise, the gypsum surrounding the joints may crumble over time and cause the screws to be loosened and stripped. This may lead to physical injury or equipment damage.

Search for other spots if there are less than two studs, or the distance between the studs are different from the plate hanger.

Fix the installation plate without inclining to one side.

42English

Image 43
Contents Questions or COMMENTS? Air conditioner Contents Installation For Installation Safety InformationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning Correct disposal of batteries in this product Display Indoor Unit Overview09/12/18 24/30 Two 1.5V AAA type batteries Remote Control OverviewControlling temperature Remote Control OperationOperation modes Controlling air flow direction Controlling fan speedHorizontal air flow manual Cooling Operation Cool modeStep cooling function Dehumidifying Operation Dry modeHeating Operation Heat modeAuto mode Quick Smart FeaturesFan mode Comfort function Fast functionQuiet function Beep sound functionSingle user function Energy-Saving OperationIs off Timed on/Timed off functionTo 27 C Good’sleep functionTo 23 C Heat, Fan Cleaning at a GlanceRunning Auto clean Auto HeatVacuum cleaner Soft brush Minutes Cleaning the filterMild detergent Troubleshooting Cleaning and Maintenance Cleaning and Maintenance Cleaning and Maintenance Installation of the unit Safety Information on InstallationGeneral information Power supply line, fuse, or circuit breaker Preparation Choosing the installation locationOverview of installation location requirements When installing 1 outdoor unit 6 cases Unit mmAccessories in the indoor unit package Checking and preparing accessories and toolsAccessories When installing more than 1 outdoor unit 5 cases Unit mmTools Optional accessoriesAccessories in the outdoor unit package Drilling a hole through the wallDrill the hole Be sure to drill only one hole Taping the pipes, cables, and drain hosePower & Communication cable shall not exceed 30m Indoor Unit InstallationPrepare a compressor and the following tools Optional Extending the power cableApply heat to the contraction tube to contract it Electric shock or a fire Installing and connecting the drain hoseInstall the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a gypsum board Fixing the installation plateWhen fixing the indoor unit on a wall When fixing the indoor unit on a window frameOptional Fixing the outdoor unit to a wall with a rack Outdoor Unit InstallationUsing anchor bolts Fixing the outdoor unit in placeEvacuating the air Adding refrigerant Pumping down refrigerant Installation InspectionPerforming the gas leak tests Performing final check and trial operationPumping down for removing the product