Samsung AR18MSFTBWKNTV, AR30MSFTBWKNTV, AR24MSFTBWKNTV manual Optional Extending the power cable

Page 39

Installation

Step 2.2 Optional: Extending the power cable

1Prepare a compressor and the following tools.

Tools

Spec

Shape

Crimping pliers

MH-14

 

Connection sleeve

20xØ6.5 (HxOD)

 

(mm)

 

 

 

Insulation tape

Width 19 mm

 

Contraction tube

70xØ8.0 (LxOD)

 

(mm)

 

 

 

2As shown in the figure, peel off the shields from the rubber and wire of the power cable.

Peel off 20 mm of cable shields from the pre- installed tube.

CAUTION

For information about the power cable specifications for indoor and outdoor units, refer to the installation manual.

After peeling off the tube wire, you must insert a contraction tube.

Power cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

20

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

180

 

 

 

(Unit: mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Pre-installed tube for the power cable

 

 

 

 

 

 

 

 

 

 

 

 

(Unit: mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

3Insert both sides of core wire of the power cable into the connection sleeve.

Method 1: Push the core wire into the sleeve from both sides.

Method 2: Twist the wire cores together and push it into the sleeve.

Method 1

Method 2

 

 

 

 

 

 

 

Connection sleeve

Connection sleeve

4Using a crimping tool, compress the two points and flip it over and compress another two points in the same location.

The compression dimension should be 8.0.

Compression dimension

After compressing it, pull both sides of the wire to make sure it is firmly pressed.

Method 1

Method 2

Compress it 4 times

Compress it 4 times

5 mm

5 mm

5Wrap it with the insulation tape twice or more and position your contraction tube in the middle of the insulation tape.

Three or more layers of insulation are required.

Method 1

 

Method 2

 

Insulation tape

 

Insulation tape

 

 

 

 

 

 

 

 

 

 

 

40 mm

 

 

 

 

35 mm

 

 

 

 

6Apply heat to the contraction tube to contract it.

Contraction tube

7After tube contraction work is completed, wrap it with the insulation tape to finish.

Insulation tape

CAUTION

Make sure that the connection parts are not exposed to outside.

Be sure to use insulation tape and a contraction tube made of approved reinforced insulating materials that have the same level of withstand voltage with the power cable. (Comply with the local regulations on extensions.)

38English

Image 39
Contents Questions or COMMENTS? Air conditioner Contents Installation For Installation Safety InformationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning Correct disposal of batteries in this product Indoor Unit Overview Display09/12/18 24/30 Two 1.5V AAA type batteries Remote Control OverviewRemote Control Operation Controlling temperatureOperation modes Controlling fan speed Controlling air flow directionHorizontal air flow manual Cool mode Cooling OperationStep cooling function Dehumidifying Operation Dry modeHeating Operation Heat modeQuick Smart Features Auto modeFan mode Comfort function Fast functionQuiet function Beep sound functionSingle user function Energy-Saving OperationIs off Timed on/Timed off functionGood’sleep function To 27 CTo 23 C Heat, Fan Cleaning at a GlanceRunning Auto clean Auto HeatCleaning the filter Vacuum cleaner Soft brush MinutesMild detergent Troubleshooting Cleaning and Maintenance Cleaning and Maintenance Cleaning and Maintenance Safety Information on Installation Installation of the unitGeneral information Power supply line, fuse, or circuit breaker Preparation Choosing the installation locationOverview of installation location requirements When installing 1 outdoor unit 6 cases Unit mmAccessories in the indoor unit package Checking and preparing accessories and toolsAccessories When installing more than 1 outdoor unit 5 cases Unit mmTools Optional accessoriesAccessories in the outdoor unit package Drilling a hole through the wallDrill the hole Be sure to drill only one hole Taping the pipes, cables, and drain hosePower & Communication cable shall not exceed 30m Indoor Unit InstallationOptional Extending the power cable Prepare a compressor and the following toolsApply heat to the contraction tube to contract it Electric shock or a fire Installing and connecting the drain hoseInstall the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a gypsum board Fixing the installation plateWhen fixing the indoor unit on a wall When fixing the indoor unit on a window frameOptional Fixing the outdoor unit to a wall with a rack Outdoor Unit InstallationUsing anchor bolts Fixing the outdoor unit in placeEvacuating the air Adding refrigerant Pumping down refrigerant Installation InspectionPerforming the gas leak tests Performing final check and trial operationPumping down for removing the product