Problem

Solution

 

 

 

• When refrigerant flow changes, noise may

Noise is

be generated, depending on the status

generated.

of the air conditioner. This is a normal

 

operation.

 

 

Smoke is

• If may not be a fire but it can be a steam

generated from the outdoor heat exchanger

generated from

while the defrost function is running in the

the outdoor unit.

Heat mode in winter.

 

 

 

Water drops

• Condensation may develop when the

from the pipe

ambient temperature changes excessively.

connections of

This is a normal operation.

the outdoor unit.

 

 

 

Cleaning and Maintenance

30English

Image 31
Contents Questions or COMMENTS? Air conditioner Contents Installation For Installation Safety InformationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning Correct disposal of batteries in this product Display Indoor Unit Overview09/12/18 24/30 Two 1.5V AAA type batteries Remote Control OverviewControlling temperature Remote Control OperationOperation modes Controlling air flow direction Controlling fan speedHorizontal air flow manual Cooling Operation Cool modeStep cooling function Dehumidifying Operation Dry modeHeating Operation Heat modeAuto mode Quick Smart FeaturesFan mode Comfort function Fast functionQuiet function Beep sound functionSingle user function Energy-Saving OperationIs off Timed on/Timed off functionTo 27 C Good’sleep functionTo 23 C Heat, Fan Cleaning at a GlanceRunning Auto clean Auto HeatVacuum cleaner Soft brush Minutes Cleaning the filterMild detergent Troubleshooting Cleaning and Maintenance Cleaning and Maintenance Cleaning and Maintenance Installation of the unit Safety Information on InstallationGeneral information Power supply line, fuse, or circuit breaker Preparation Choosing the installation locationOverview of installation location requirements When installing 1 outdoor unit 6 cases Unit mmAccessories in the indoor unit package Checking and preparing accessories and toolsAccessories When installing more than 1 outdoor unit 5 cases Unit mmTools Optional accessoriesAccessories in the outdoor unit package Drilling a hole through the wallDrill the hole Be sure to drill only one hole Taping the pipes, cables, and drain hosePower & Communication cable shall not exceed 30m Indoor Unit InstallationPrepare a compressor and the following tools Optional Extending the power cableApply heat to the contraction tube to contract it Electric shock or a fire Installing and connecting the drain hoseInstall the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a gypsum board Fixing the installation plateWhen fixing the indoor unit on a wall When fixing the indoor unit on a window frameOptional Fixing the outdoor unit to a wall with a rack Outdoor Unit InstallationUsing anchor bolts Fixing the outdoor unit in placeEvacuating the air Adding refrigerant Pumping down refrigerant Installation InspectionPerforming the gas leak tests Performing final check and trial operationPumping down for removing the product