Samsung AR30MSFTBWKNTV manual Installing and connecting the drain hose, Electric shock or a fire

Page 40

WARNING

In case of extending the electric wire, please DO NOT use a round-shaped pressing socket.

––Incomplete wire connections can cause

electric shock or a fire.

Step 2.3 Installing and connecting the drain hose

1Install the drain hose.

Drain hose

Assembly pipe

Connection hose

Wall

 

 

Indoor unit

 

 

Drain hose

 

 

Slant downwards

Slant upwards

Dipped in water

 

 

5 cm

 

 

less

 

 

Ditch

Bent

Too small

Too small

 

clearance

clearance

2Pour water into the drain pan. Check whether the hose is well drained.

CAUTION

Make sure that the indoor unit is in upright position when you pour water to check for leakage. Make sure that the water does not overflow onto the electrical part.

If the diameter of the connection hose is smaller than the product's drain hose, water leakage may occur.

Inadequate installation may cause water leakage.

If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the furniture or floors.

Do not box in or cover the drain hose connection. Drain hose connection must be easily accessible and serviceable.

Step 2.4 Optional: Extending the drain hose

Drain hose (A) Extension drain hose (B)

 

 

40~45mm

 

(A)

(B)

Drain hose

Extension drain hose

20 mm or more

Foam insulation

Vinyl tape

Installation

English 39

Image 40
Contents Questions or COMMENTS? Air conditioner Contents Installation Safety Information For InstallationSafety Information For Power Supply For Using Safety Information Safety Information For Cleaning Correct disposal of batteries in this product Display Indoor Unit Overview09/12/18 24/30 Remote Control Overview Two 1.5V AAA type batteriesControlling temperature Remote Control OperationOperation modes Controlling air flow direction Controlling fan speedHorizontal air flow manual Cooling Operation Cool modeStep cooling function Dry mode Dehumidifying OperationHeat mode Heating OperationAuto mode Quick Smart FeaturesFan mode Fast function Comfort functionBeep sound function Quiet functionEnergy-Saving Operation Single user functionTimed on/Timed off function Is offTo 27 C Good’sleep functionTo 23 C Cleaning at a Glance Running Auto cleanAuto Heat Heat, FanVacuum cleaner Soft brush Minutes Cleaning the filterMild detergent Troubleshooting Cleaning and Maintenance Cleaning and Maintenance Cleaning and Maintenance Installation of the unit Safety Information on InstallationGeneral information Power supply line, fuse, or circuit breaker Choosing the installation location Overview of installation location requirementsWhen installing 1 outdoor unit 6 cases Unit mm PreparationChecking and preparing accessories and tools AccessoriesWhen installing more than 1 outdoor unit 5 cases Unit mm Accessories in the indoor unit packageOptional accessories Accessories in the outdoor unit packageDrilling a hole through the wall ToolsTaping the pipes, cables, and drain hose Drill the hole Be sure to drill only one holeIndoor Unit Installation Power & Communication cable shall not exceed 30mPrepare a compressor and the following tools Optional Extending the power cableApply heat to the contraction tube to contract it Installing and connecting the drain hose Install the drain hoseOptional Extending the drain hose Electric shock or a fireOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum boardOutdoor Unit Installation Using anchor boltsFixing the outdoor unit in place Optional Fixing the outdoor unit to a wall with a rackEvacuating the air Adding refrigerant Installation Inspection Performing the gas leak testsPerforming final check and trial operation Pumping down refrigerantPumping down for removing the product