F. Positioning the Logs

While still breakable, the logs do not become fragile until after the appliance is burned and they have cured. After curing, any handling must be done with care as breakage can easily occur.

PLEASE NOTE: Logs have been designed to work specifically with the burner of this appliance. Exact placement will ensure proper operation of your gas appliance and reduce sooting.

Notch

G. Mineral Wool

WARNING

Explosion Risk.

Follow ember placement instructions in manual.

Do NOT place embers directly over burner ports.

Replace ember material annually.

Improperly placed embers interferes with proper burner operation.

#1

Location Pins

Figure 8.11 Position rear log (#1) over the two locating pins.

#2

Figure 8.12 Put right front log (#2) into place on burner. Lean log back towards rear log until it fi ts into notch in rear log.

#1

#3

#2

Figure 8.14 Place individual pieces of embers in front of and around the gas log where they can be seen. Space them so that gas can contact them on all sides. Avoid stacking the embers on top of each other.

NOTE: Do not block gas ports.

H. Opening Front Door

The front door is held closed by a magnet. To open the door, pull gently from the right side as you face the appliance.

Figure 8.13 Place left front log (#3) into place on burner.

July 29, 2008

Quadra-Fire · Castile Gas Stove · 7023-111E

Page 31

Image 31
Contents Hot glass will cause burns What to do if you smell gasDo not Discard this Manual Do DiscardnotWelcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals BELOW. Keep Clear of ALL Obstructions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Inspect Appliance & Components Design & Installation ConsiderationsTools will apply to every installation Getting StartedClearances Selecting Appliance LocationVent Termination Minimum Clearances 4Termination LocationsAlcove Applications Measuring Standards Vent InformationVenting Components Use of ElbowsExceptions for Horizontal Installations How to Use the Vent Graph Venting GuidelinesHorizontal Termination Type a Up and Out InstallationType B Straight Out Installation Type C 45 Elbow in Corner Installation203mm Step Direct Vent Pipe Vertical TerminationStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type B Type C Up & Out InstallationType a & B Co-Axial to Co-Linear Existing Masonry Chimney Type aCut and bend flashing as needed to fit Sealant adhesive Retro Connector Propane Natural GAS Gas InformationFuel Conversions Converting to LP GasScrews Rubber Gasket Identification Label F Valve Regulator ReplacementPressure Gas Pressures Gas ConnectionCheck for GAS Leaks Wire Size Max. Length Recommendation for WireConnecting to the Appliance Standing Pilot Ignition System WiringON/OFF Top to Rear Vent Conversion Appliance SetupAccessories Remove Shipping MaterialsLeg Leveling System Baf e Installation/AdjustmentMineral Wool Positioning the LogsOpening Front Door 16 nut Snap disc through bracket Glass Door Assembly Blower InstallationBlower Shutter Adjustment Damper Adjustment For top or rear vent installationsBefore Lighting Appliance Operating InstructionsControls Lighting Appliance For Your Safety Read Before LightingInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Symptom Possible Cause Corrective Action TroubleshootingBe Placed in this Opening After servicing Maintaining and Servicing Your ApplianceNecessary. USE Caution When CLEANING/HANDLING Ceramic Burner Maintenance Tasks InspectReference Materials Appliance Dimension DiagramSL-D Series Vent Components Vent Components DiagramHHT SL-P Vent Components ListTermination Caps & Kits Castile GAS Nbr Description Service Parts List cont’d. Castile GASSKU Part DescriptionAlphabetical Order RV-CG-MBK Accessories Warranty Policy Lifetime WarrantyContact Information Castile GasDealer Telephone