I. Glass Door Assembly | J. Blower Installation |
Figure 8.15 Turn the appliance OFF and let it cool down before replacing the inner glass door assembly.
Remove the glass door assembly by opening latches at the bottom front of the appliance, on both the left and right sides. Lift out and away from the appliance.
Replace with a new glass door assembly.
NOTE: The glass, gasketing, and frame must be replaced as a complete unit as supplied by the manufacturer.
Do NOT use substitute material.
FROM THE KIT YOU WILL NEED: Blower motor; wire harness; rheostat; rheostat nut; knob; screws; and 1
FROM THE STOVE COMPONENT BAG YOU WILL NEED: snap disc bracket and 5/16 in. nut.
TOOLS REQUIRED: #2 Phillips head bit; hand drill; 11/16 in. wrench; and a 5/16 in. wrench.
Figure 8.16 Turn off gas supply (if gas is connected), and remove the rear shield. Remove the blower from packaging. Place the blower under the appliance. Attach the blower from the front with four screws to the blower bracket.
5/16" nut
Snap disc through bracket
Figure 8.17 Install the snap disc in the bracket. Attach the bracket to the fi rebox with a 5/16 in. wrench.
CAUTION
Handle glass assembly with care.
•Inspect the gasket to ensure it is undamaged.
•Inspect the glass for cracks, chips or scratches.
•Do NOT strike, slam or scratch glass.
•Do NOT operate appliance with glass door removed, cracked, broken or scratched.
•Replace glass assembly as a complete assembly.
Figure 8.18 Connect the electrical connector to the snap disc.
Page 32 |
| July 29, 2008 |