C. Vent Components List

Description

HHT SL-P

Simpson

Selkirk®

Amerivent

Security

 

M= Multi Pack (6)

Dura-Vent ®

Direct-Temp

Direct ®

Secure Vent®

 

 

DirectVent Pro

 

 

 

 

4” Pipe Length, Galvanized

SLP4M

-

-

-

-

 

4” Pipe Length, Black

SLP4-BK

-

-

-

-

 

6” Pipe Length, Galvanized

SLP6M

46-DVA-06

4DT-6

-

SV4L6

6” Pipe Length, Black

SLP6-BK

46-DVA-06B

4DT-6B

-

SV4LB6

7” Pipe Length, Galvanized

-

-

-

4D7

-

 

7” Pipe Length, Black

-

-

-

4D7B

-

 

9” Pipe Length, Galvanized

-

46-DVA-09

4DT-9

-

-

 

9” Pipe Length, Black

-

46-DVA-09B

4DT-9B

-

-

 

12” Pipe Length, Galvanized

SLP12M

46-DVA-12

4DT-12

4D12

SV4L12

12” Pipe Length, Black

SLP12-BK

46-DVA-12B

4DT-12B

4D12B

SV4LB12

18” Pipe Length, Galvanized

-

46-DVA-18

4DT-18

-

-

 

18” Pipe Length, Black

-

46-DVA-18B

4DT-18B

-

-

 

24” Pipe Length, Galvanized

SLP24M

46-DVA-24

4DT-24

4D2

SV4L24

24” Pipe Length, Black

SLP24-BK

46-DVA-24B

4DT-24B

4D2B

SV4LB24

36” Pipe Length, Galvanized

SLP36M

46-DVA-36

4DT-36

4D3

SV4L36

36” Pipe Length, Black

SLP36-BK

46-DVA-36B

4DT-36B

4D3B

SV4LB36

48” Pipe Length, Galvanized

SLP48M

46-DVA-48

4DT-48

4D4

SV4L48

48” Pipe Length, Black

SLP48-BK

46-DVA-48B

4DT-48B

4D4B

SV4LB48

Adjustable Length, 3”-6”, Black

SLP6A-BK

-

-

-

 

 

Adjustable Length, 3”-6”, Galvanized

SLP6AM

-

-

-

-

 

Adjustable Length, 3”-7”, Galvanized

-

46DVA-08A

-

-

-

 

Adjustable Length, 3”-7”, Black

-

46DVA-08AB

-

-

-

 

Adjustable Length, 3”-12”, Black

SLP12A-BK

-

-

-

-

 

Adjustable Length, 3”-12”, Galvanized

SLP12AM

-

-

-

-

 

Adjustable Length, 3”-14.5”, Galvanized

-

46DVA-16A

-

-

-

 

Adjustable Length, 3”-14.5”, Black

-

46DVA-16AB

-

-

-

 

Adjustable Length, 7”, Galvanized

-

-

-

4D7A

-

 

Adjustable Length, 7”, Black

-

-

-

4F7AB

-

 

Adjustable Length, 11”-14”, Galvanized

-

-

4DT-AJ

-

-

 

Adjustable Length, 11”-14”, Black

-

-

4DT-AJB

-

-

 

Adjustable Length, 12”, Galvanized

-

4DTAJ12

-

4D12A

SV4LA12

Adjustable Length, 12”, Black

-

4DTAJ12-B

-

4D12AB

SV4LBA12

Adjustable Length, 16”, Galvanized

-

46DVA-16A

-

4D16A

-

 

Adjustable Length, 16”, Black

-

46DVA-16AB

-

-

-

 

Adjustable Length, 24”, Galvanized

-

-

-

-

SV4LA24

Adjustable Length, 24”, Black

-

-

-

-

SV4LBA24

2’ Flexible Pipe Length

SLP-FLEX-2

-

-

-

-

 

3’ Flexible Pipe Length

SLP-FLEX-3

-

-

-

-

 

5’ Flexible Pipe Length

SLP-FLEX-5

-

-

-

-

 

10’ Flexible Pipe Length

SLP-FLEX-10

-

-

-

-

 

3” x 35’ Flex Extension

-

2280

-

-

-

 

4” x 35’ Flex Extension

-

2281

-

-

-

 

45° Elbow, Galvanized

SLP45M

-

-

-

-

 

45° Elbow, Black

SLP45-BK

See Swivel

4DT-EL45B

4D45LB

SV4EBR45

45° Elbow, Swivel, Galvanized

-

46DVA-E45

-

-

SV4E45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 44

Quadra-Fire · Castile Gas Stove · 7023-111E

July 29, 2008

Image 44
Contents What to do if you smell gas Do not Discard this ManualDo Discardnot Hot glass will cause burnsWelcome to the Quadra-Fire Family Table of Contents 1Listing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsBELOW. Keep Clear of ALL Obstructions Design & Installation Considerations Tools will apply to every installationGetting Started Inspect Appliance & ComponentsSelecting Appliance Location Clearances4Termination Locations Vent Termination Minimum ClearancesAlcove Applications Vent Information Venting ComponentsUse of Elbows Measuring StandardsHow to Use the Vent Graph Venting Guidelines Exceptions for Horizontal InstallationsType a Up and Out Installation Type B Straight Out InstallationType C 45 Elbow in Corner Installation Horizontal Termination203mm Step Vertical Termination Direct Vent PipeStep Twist-lock the vent cap and seal Cathedral Ceiling Class a Metal Chimney Type C Up & Out Installation Type a & B Co-Axial to Co-LinearExisting Masonry Chimney Type a Type BCut and bend flashing as needed to fit Sealant adhesive Retro Connector Gas Information Fuel ConversionsConverting to LP Gas Propane Natural GASValve Regulator Replacement Screws Rubber Gasket Identification Label FGas Pressures Gas Connection PressureCheck for GAS Leaks Recommendation for Wire Connecting to the ApplianceStanding Pilot Ignition System Wiring Wire Size Max. LengthON/OFF Appliance Setup AccessoriesRemove Shipping Materials Top to Rear Vent ConversionBaf e Installation/Adjustment Leg Leveling SystemOpening Front Door Positioning the LogsMineral Wool Glass Door Assembly Blower Installation 16 nut Snap disc through bracketBlower Damper Adjustment For top or rear vent installations Shutter AdjustmentControls Operating InstructionsBefore Lighting Appliance For Your Safety Read Before Lighting Lighting ApplianceAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Troubleshooting Symptom Possible Cause Corrective ActionBe Placed in this Opening Maintaining and Servicing Your Appliance After servicingMaintenance Tasks Inspect Necessary. USE Caution When CLEANING/HANDLING Ceramic BurnerAppliance Dimension Diagram Reference MaterialsVent Components Diagram SL-D Series Vent ComponentsVent Components List HHT SL-PTermination Caps & Kits Castile GAS Service Parts List cont’d. Castile GAS Nbr DescriptionAlphabetical Order Part DescriptionSKU RV-CG-MBK Accessories Lifetime Warranty Warranty PolicyDealer Telephone Castile GasContact Information